According to EN14764:2005 , ISO4210-2014
The machine is designed and manufactured according to the standard, the foot pedal or hub is installed on the rotating axis of the instrument, and the load is applied and the set speed is selected according to the specification. The machine is designed and manufactured according to the standard, and the foot pedal or hub is installed on the rotating axis of the instrument.
Test frequency | 0~120 times/min adjustable |
Counters | 0~999999 set automatic stop |
Counter (each) | Four groups of each counting destruction stop counting |
Number of tests | 4pcs |
Weight | 30kg,50kg,65kg(Combination) |
Rotation accuracy | ±1 rpm |
Power source | Inverter motor |
Dimension | 1523*850*1350mm (W*D*H) |
Weight (approx.) | 300KG |
Power source | AC220V,15A |