Tested wires length:600mm(24 in) :
Sample clamping Angle:45 degree
Burning gas using high purity propane gas :
liquefied petroleum gas
Automatic ignition :
flame burn the sample continue 15 seconds and be off automatically
Burning gas is not supplied with the tester :
it should be supplied by customer
Meet standards :
UL94, ISO 6722
Description

SL-S29 Horizontal-Vertical Flammability Tester

Product Introduction

Horizontal and Vertical Flammability Testing Machine

UL 94 flame chamber. Horizontal flame chamber, vertical flame chamber

For the flammability testing of plastic materials used in consumer electric devices and appliances. Stainless steel construction with black interior and large sliding window for easy viewing. Includes a fully adjustable specimen support and precision gas flow controls.

This test chamber mainly for the conductor diameter greater than 8mm (section area is greater than 0.5mm2) or less than 8mm (section area less than 0.5mm2) of single wire and cable flammability evaluation. Suitable for lighting equipment, low-voltage electrical appliances, household appliances, electrical tools, electric motor, electric tools, electronic instruments, electrical instruments, electrical connectors and accessories such as electrical and electronic products and components of the research, production and quality inspection department.

Test Standard

UL 94-2006 IEC 60695-11-3 IEC 60695-11-4

UL94:Tests for Flammability of Plastic Materials for Parts in Devices and Appliances UL94HB: Horizontal Burning Test

V-0,1,2: 20mm Vertical Burning Test

94-5VA,B: 500W(125mm) Vertical Burning Test 94VTM-0,1,2: Thin Material Vertical Burning Test

94HBF,94HF-1,2 : Horizontal Burning Foamed Material Test

IEC 60695-11-10:Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods

IEC 60695-11-20: Fire hazard testing - Part 11-20: Test flames - 500 W flame test methods

IEC 60695-11-4:Fire hazard testing - Part 11-4: Test flames - 50 W flames-Apparatus and conformational test method

IEC 60695-11-3:Fire hazard testing - Part 11-3: Test flames - 500 W flames-Apparatus and conformational test method

ISO 6722

Technical Parameter

Kinds 500W(5V class ) 50W(HB/Vclass)
Test Flame 500W(burning test for V-0,V-1,V-2 classification) 50W(burning test for V-0,V-1,V-2 classification)
Burner Tube Internal diameter: Φ 9.5mm±0.3mm Internal diameter: Φ 9.5mm±0.3mm,
Burning Angle 0°,20°,45° 0°,20°,45°
Thermocouple Type K (Ni/Cr - Ni/Al) Type K (Ni/Cr - Ni/Al)
Thermocouple Size 0.5 mm 0.5 mm
Standard Copper Block 9mm±0.01mm, weight:10g±0.05g before drilling. 5.5mm±0.01mm, weight:76g±0.01g before drilling.
Time for Temperature to Increase

From 100°C±5°C to 700°C±3°C;

54s±2s (preset)

From 100°C±5°C to 700°C±3°C;

44s±2s (preset)

Gas Flow 965±32ml/min 105±10ml/min
Gas Supply methane,min.98% purity methane,min.98% purity
Water-column 125m±5mm ‹10mm
Test Time 54±2s 44±2s
Flame Height Indicator 40±1mm 20±1mm
Volume Of Chamber >0.5m³, black interior >0.5m³, black interior
Conform to standard UL94,IEC60695-11-3,IEC60695-11-20 UL94,IEC60695-11-4,IEC60695-11-10

Burning gas using high purity propane gas liquefied petroleum gas
Tested wires length:600mm(24 in) Sample clamping Angle:45 degree
The bunsen burner has 13mm inlet hole and 10mm (3/8 in) nominal diameter, spray fire pipe outer flame diameter is 100mm (4in) inner flame is 50 mm(1/2in),temperature of inner flame as least 900 degree celsius
The Bunsen burner flame should be put in the bottom of the samples and perpendicular to the axis of the sample The tip of the inner flame role should be in the midpoint of the sample
Automatic ignition flame burn the sample continue 15 seconds and be off automatically
After burning 15 seconds will time the continued burning, complete the continued burning time until the continued burning crush out and put off the stop button

Burning gas is not supplied with the tester

it should be supplied by customer

Features

Single cable vertical burning test is set by size Bunsen (Bunsen burner) and the specific gas source (Bing Wan), according to a certain flame height and some application of flame angle on the vertical state of the sample application to test ignition timing, ignition, combustion duration and combustion to assess its length flammable and fire hazard.

Send your message to this supplier
Send Now

Horizontal Vertical Flammability Test Chamber UL94, ISO 6722

Ask Latest Price
Brand Name :
Skyline
Model Number :
SL-S29
Certification :
CE, Rosh, Calibration
Place of Origin :
China
MOQ :
1
Price :
Negotiable
Contact Supplier
Horizontal Vertical Flammability Test Chamber UL94, ISO 6722
Horizontal Vertical Flammability Test Chamber UL94, ISO 6722
Horizontal Vertical Flammability Test Chamber UL94, ISO 6722

SKYLINE INSTRUMENTS CO.,LTD

Verified Supplier
8 Years
guangdong, dongguan
Since 2011
Business Type :
Manufacturer, Distributor/Wholesaler, Importer, Exporter, Seller
Total Annual :
120000-350000
Employee Number :
100~107
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement