Features:
1.0 The machine comply with the standards of IEC60695-11-5, IEC 60335-1, IEC60598-1 and IEC60745
2.0 Needle burner: made of stainless steel bore
3.0 Including thermocouple and display to monitor the wire temperature
4.0 Input power: 220V/50Hz
5.0 The travel unit and the glow wire is enclosed by a steel chamber
6.0 The chamber shall include a level and adjustable feet
Parameters:
Needle-shaped burner | Stainless steel,Inner bore: Φ 0.5mm ± 0.1mm ,OD ≤Φ 0.9mm ,Length ≥ 35mm |
Burner angle | Vertical ( when adjust and measure flame height )and slope of 45°(when testing ) |
Ignition base layer | 10mm thickness white pine plank,cover 12g /m 2 ~ 30g /m 2 standard silk paper,200mm ± 5mm distance under flame burner |
burning gas | 95% butane gas (standard gas ),also could use propane gas |
Gas flame temperature | 100℃ ± 2℃ ~ 700℃ ± 3℃ (room temperature~ 999℃ ) , 23.5s±1.0s(1s ~ 999.9s) |
Flame height | 12mm ± 1mm ( adjustable ) |
Time of application of flame | 5s,10s,20s,30s,60s,120s -1 +0 s(1s ~ 999.9s digital display, could preset ) |
Afterflame time | 1s ~ 999.9s(digital readout, could manual pause to retain the time ) |
Test room | ≥ 0.5 m3 ,black background |
Temperature sensor | K-type Φ 0.5mm insulated sheathed thermocouple, heat resistance 1100℃ |
Dimension | Length 1000mm × Width 650mm × Length 1300mm,Vent hole: Φ 115mm ; |
Power | 220V 0.5kVA |
Comply with Standards:
IEC60695-11-5, IEC 60335-1, IEC60598-1 and IEC60745