Specifications
Brand Name :
Haida
Model Number :
HD-E702
Certification :
CE,,ISO
Place of Origin :
China
MOQ :
1
Price :
Negotiation
Payment Terms :
L/C, T/T, D/A, D/P, Western Union, MoneyGram
Supply Ability :
75 Piece / Pieces Per Month
Delivery Time :
15 Days After Order
Packaging Details :
Strong Wooden Case
Usage :
Constant Temperature and Humidity Testing Machine
Temp. range :
-70°C~150°C
Humid. range :
10~ 98 percent R.H.
Resolution :
0.01°C, 0.1 percent, P.I.D control
Interior dimension(W×D×H) :
100×100×80cm
Interior material :
Stainless steel plate(SUS304)
Display :
LCD
Weight :
Approx. 600 kg
Power :
AC220V±10 percent 50/60Hz
Use :
temperature test equipment
Description

Temperature chamber Door opening alarm Temperature Humidity Chamber

Temperature and humidity chamber.pdf

Temperature chamber Door opening alarm Temperature Humidity Chamber can simulate different environment condition. It's appropriate for testing material performance, such as resist heat, resist dry,resist humidity and resist cold. That can define performance of material.

1. Specifications of Temperature and Humidity Stability Test Machine

Range – 70 to 150°C

Temp/Humidity

HD-E702-100-7

HD-E702-150-7

HD-E702-225-7

HD-E702-408-7

HD-E702-800-7

HD-E702-1000-7

Temp-only

HD-E702-100T-7

HD-E702-150T-7

HD-E702-225T-7

HD-E702-408T-7

HD-E702-800T-7

HD-E702-1000T-7

Temperature Range:

-70°C ~150°C

Cooling Capacity

~ 2.5 kW at -50°C

~ 3 kW at -50°C

~ 5 kW at -50°C

~ 6.5 kW at-50°C

~ 8.5 kW at -50°C

~ 9 kW at - -50°C

Heating System

~ 5 kW

~ 5 kW

~ 5.5 kW

~6.5 kW

~ 8.5 kW

~ 9 kW

Temperature Fluctuation:

±0.5°C

Temperature Gradient:

±0.5°C~±0.2°C

Heating Rate†:

≥3℃ / min average ( Advance model 5 – 15 ℃ / min)

Cooling Rate†:

≥1℃ / min average (Advance model 5 - 15℃ / min)

Humidity Range:

10%~95%RH (Ref to Normal Humidity Range Diagramed)

Humidity Fluctuation:

±1.5%RH~±2.0%RH

Humidity Gradient:

±3%RH

Dimensions

Workspace dimensions
(WxDxH)mm:

500x400x500

HD-E702-100

600x500x500

HD-E702-150

750x500x600

HD-E702-225

850x650x800

HD-E702-800

1000x1000x800

HD-E702-800

1000x1000x1000

HD-E702-1000

Exterior dimensions
(WxDxH)mm:

1400x850x1050

1500x950x1050

1650x950x1150

1750x1050x1350

1900x1450x1350

1900x1450x1550

Site Requirements

Electrical Supply:

208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific)

Humidity Water

Distilled water

Condensate Drain:

1/2" hose connection (gravity drain)

Range – 40 to 150°C

Temp/Humidity

HD-E702-100-4

HD-E702-150-4

HD-E702-225-4

HD-E702-408-4

HD-E702-800-4

HD-E702-1000-4

Temp-only

HD-E702-100T-4

HD-E702-150T-4

HD-E702-225T-4

HD-E702-408T-4

HD-E702-800T-4

HD-E702-1000T-4

Temperature Range:

-40°C ~150°C

Cooling Capacity

~ 2 kW at -20°C

~ 2.5 kW at -20°C

~ 4.5 kW at -20°C

~ 5.5 kW at-20°C

~ 8 kW at -20°C

~ 8.5 kW at - -20°C

Heating System

~ 5 kW

~ 5 kW

~ 5.5 kW

~6.5 kW

~ 8.5 kW

~ 9 kW

Temperature Fluctuation:

±0.5°C

Temperature Gradient:

±0.5°C~±0.2°C

Heating Rate†:

≥3℃ / min average ( Advance model 5 – 15 ℃ / min)

Cooling Rate†:

≥1℃ / min average (Advance model 5 - 15℃ / min)

Humidity Range:

10%~95%RH (Ref to Normal Humidity Range Diagramed)

Humidity Fluctuation:

±1.5%RH~±2.0%RH

Humidity Gradient:

±3%RH

Dimensions

Workspace dimensions
(WxDxH)mm:

500x400x500

HD-E702-100

600x500x500

HD-E702-150

750x500x600

HD-E702-225

850x650x800

HD-E702-800

1000x1000x800

HD-E702-800

1000x1000x1000

HD-E702-1000

Exterior dimensions
(WxDxH)mm:

1400x850x1050

1500x950x1050

1650x950x1150

1750x1050x1350

1900x1450x1350

1900x1450x1550

Site Requirements

Electrical Supply:

208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific)

Humidity Water

Distilled Water

Condensate Drain:

1/2" hose connection (gravity drain)

2. Performance

Get a performance evaluation to help provide the suitable chambers to you.

For better assurance of performance for your temperature and humidity cycling application, Haida can provide a guaranteed performance calculation based on your submitted requirements.

Please use these questions as below as a guide to define your test plan. You can then give this information to our lab consultant or email to us, for review by our lab consultant. A recommended model with appropriate refrigeration size will provide to you.

Questions for Performance Evolution Request

Temperature chamber Door opening alarm Temperature Humidity Chamber

System & Performance Options

  • Low and Ultra-Low Humidity Extends the humidity control range. (Normal Humidity Range Diagramed)
  • Water-cooling system.
  • Dry Air Purge keeps moisture in the chamber extremely low by purging with -40 °C. Compressed air supply required
  • Additional shelves, 50 Kg loading
  • Cable ports with flexible silicone plug, 50 , 100, 150mm or customer specific diameters

Temperature chamber Door opening alarm Temperature Humidity Chamber

(Normal Humidity Range Diagramed)

3. Features of Temperature and Humidity Stability Test Machine

Vice lock type door and foam silicone packing to ensure a perfect seal Cartridge type tank for easy adding and changing of water

Tempered glass window with lamps provides a clear view of samples in the chamber, beneficial during testing Easy cleaning of condenser air-filter to prevent deterioration of refrigeration system

Leakage breaker for power supply Over current protection Overheat / overcool protection Switch-off after alarm for over heating Water empty / Door open alarm Vice lock door type locking mechanism

Standard Features

  • Stainless# 304 steel for interior
  • Paint steel for exterior
  • Foam-insulated door for rigidity and long life
  • Plastic water tank easy for maintenance
  • Observation Window with frost free function
  • High performance refrigeration system
  • Easy user interface for TEMI-880 PLC controller
  • One 100mm cable port/ Customer specified
  • One shelve, 10 Kg loading & 4 casters included
  • Van Type Sirocco,L134,Fan
  • PID controlled-Stainless Steel Humidifier
  • DuPont R-404A [No Fluorine] Refrigerant / 23 for below -40 °C
  • USB port for data output
  • Anti-explosive interior lamps
  • Data logging chart recorders, paperless recorders stored data in the PLC.
Send your message to this supplier
Send Now

Temperature chamber Door opening alarm Temperature Humidity Chamber

Ask Latest Price
Watch Video
Brand Name :
Haida
Model Number :
HD-E702
Certification :
CE,,ISO
Place of Origin :
China
MOQ :
1
Price :
Negotiation
Contact Supplier
video
Temperature chamber Door opening alarm Temperature Humidity Chamber
Temperature chamber Door opening alarm Temperature Humidity Chamber
Temperature chamber Door opening alarm Temperature Humidity Chamber
Temperature chamber Door opening alarm Temperature Humidity Chamber

Hai Da Labtester

Verified Supplier
11 Years
guangdong, dongguan
Since 2004
Business Type :
Manufacturer, Seller
Total Annual :
$ 5 Million-US$ 10 Million
Employee Number :
200~300
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement