Slim 12V 60W 5A LED Driver Strips Light Box LED Module Al CV Ultra Thin Power
Quick Detail:
Description:
Our products are widely used in LED industrial project, communications power, aerospace, industrial control systems, posts communications, medical equipment and other industrial and commercial fields. All these products adopt PWM high-frequency pulse width modulation technology, mature standardized production, strict 100% load-carrying aging, high and low voltage impact experiments and complete test records for development & production of LED driver through strictly quality control system and highly responsible attitude, thus have a good quality feedback during application.
Indoor drivers slim line and ultra thin have 12V,24V series include 24W, 36W, 48W, 60W,100W,150W, 200W, 300W,400W etc. they are mainly used for LED strips light, light belt, LED module, light box/lamp house etc.
Specifications:
Series | Name | Slim line LED Driver |
1 | Basic info | 12V 5A 60W |
2 | Model | S-60W-12V( indoor) |
3 | Material | Aluminum |
4 | Efficiency | 75% |
5 | Rated input | 220VAC 50/60Hz |
6 | Voltage Range | 170-250VAC |
7 | Output Voltage | DC12V±5% |
8 | Output Current | 5A |
9 | Output Power | 60W |
10 | Grade | IP20 |
12 | Protect | Shortage/Overload/Over voltage/Over current |
13 | Dimension | 12.6*4.7*3.2CM |
14 | Weight | 164g |
Notices:
1. Input voltage should be within the specified voltage range (for examples: input voltage 220VAC).
2. Prohibited to be used in the high temperature environment, power port is the thermal vents, wind 50CM range, please do not place other objects, make sure that the power should have good thermal dissipation space environment.
3. Prohibited to install power supply in the presence of flammable materials (such as wood products, flammable plastic, etc), to stay away from petrol stations or where prohibited Fireworks.
4. Accurate calculation of load power, peak use, suggested user to use power supply based on power 80% load, do not overload.
5. Power supply have built-in short circuit protection function, when output short circuit, the power will automatically enter the status. Power off after 1 minute and then power on.
6. For safety, properly grounded, the output power cable must be ≥2.5mm2
7. Strictly in accordance with the position indicated by the output terminals of the power supply. It must be firm, check the output line and prohibited to be reversed (input "220VAC" main line, output "+" loaded for positive cathode, output "-" load for negative cathode).
8. Before power, check that the line voltage is compatible with the operating voltage with multimeter (voltage: 220VAC) recognized before it can be closed.
9. Power firm installed vertically (vertically in a place easy to wire the power supply, cover to cover, to be water proof)
Ultra thin LED drivers 12V 24V related models list:
Model | Input Voltage | Output Value | Size/cm | Weight |
S-24W-12V-S | 170-250V | 12V 2A 24W | 20.5*1.8*1.8 | 70 |
S-36W-12V-S | 170-250V | 12V 3A 36W | 28.5*1.8*1.8 | 80 |
S-48W-12V-S | 170-250V | 12V 4A 48W | 31.3*1.8*1.8 | 82 |
S-60W-12V-S | 170-250V | 12V 5A 60W | 33.0*1.8*1.8 | 95 |
S-72W-12V-S | 170-250V | 12V 6A 72W | 38.0*1.8*1.8 | 102 |
S-120W-12V-S | 170-250V | 12V 10A 120W | 14.5*5.3*2.0 | 170 |
S-150W-12V--S | 170-250V | 12V 12.5A 150W | 16.8*5.3*2.2 | 250 |
S-200W-12V-S | 170-250V | 12V 16.67A 200W | 23.5*5.3*2.2 | 300 |
S-300W-12V-S | 170-250V | 12V 25A 300W | 30.7*5.3*2.2 | 355 |
S-400W-12V-S | 170-250V | 12V 33A 400W | ||
S-24W-24V-S | 170-250V | 24V 1A 24W | 20.5*1.8*1.8 | 70 |
S-36W-24V-S | 170-250V | 24V 1.5A 36W | 28.5*1.8*1.8 | 80 |
S-48W-24V-S | 170-250V | 24V 2A 48W | 31.3*1.8*1.8 | 82 |
S-60W-24V-S | 170-250V | 24V 2.5A 60W | 33.0*1.8*1.8 | 95 |
S-72W-24V-S | 170-250V | 24V 3A 72W | 31.3*1.8*1.8 | 73 |
S-120W-24V-S | 170-250V | 24V 5A 120W | 14.5*5.3*2.0 | 170 |
S-150W-24V-S | 170-250V | 24V 6.25A 150W | 16.8*5.3*2.2 | 250 |
S-200W-24V-S | 170-250V | 24V 8.33A 200W | 23.5*5.3*2.2 | 300 |
S-300W-24V-S | 170-250V | 24V 12.5A 300W | 30.7*5.3*2.2 | 355 |
S-400W-24V-S | 170-250V | 24V 16.67A 400W |
Applications:
Widely used in LED Lighting, LED display, LED strips, LED advertisement screen, LED sign, LED night light, LED lamp house, LED decoration, LED wall light, LED street light , LED wall light, LED backlight, LED tube, offices , hospital , schools , factories , plants, shopping malls, supermarkets, kitchen, fair cabinet and so on.
FAQ
1. How many kinds of led drivers you produce?
A: There are many kinds of led drivers: indoor type, rain proof type, waterproof type, ultra thin type, high power type.
2. Do you have CE, ETL approval?
A: Most of products have CE approval, some products have ETL approval.
3. Can I place a sample order?
A: Yes, sample order is available after full test and before delivery. If big quantity, it maybe need 12-18 working days.
4. What about the lead time?
A: 3-5 days for Sample, 8-12 working days for mass production.
5. Which tests do you carry out in your factory?
A: We usually do overload test, 1600V high voltage test and 100% old age test.
6. What is MOQ for led driver?
A: MOQ usually is 100-200pcs except sample order.
7. How do you ship the goods and how long does it take to arrive?
A: We ship by sea, by railway or by sea. If samples, always by express such as FEDEX or DHL etc. It all depends.
8. How about the payment terms?
A: T/T for sample order and small quantity order and L/C for large quantity order.
9. How to start an order with each other?
A: Know your true requirements or application fully, quote based on your requirements and our suggestions, confirms the samples and places deposit for formal order and we arrange the mass production.
10. OEM and ODM is acceptable?
A: Yes. Our cooperation is flexible, OEM or ODM is acceptable.
11: Do you offer warranty period for the products as a part of after sale service?
A: Yes, we offer 3 years warranty for our products after delivery.
12: How to deal with the defectives?
A:
Firstly, our products are produced under strict quality control system and the defective rate will be less than 0.2%.
Secondly, during the guarantee period, we will send new goods together with new order for small quantity.
Thirdly, for defective batch products, we will investigate into the true problems happened, find the real reasons and discuss the suitable solution including recall them based on real situation.
Test methods for switching power supply
1. withstand voltage testing
Definition: withstand the effective value of AC between specified terminals such as I/P-O/P, I/P-FG, O/P-FG, leakage current is generally allowed to be 10 MA and the time of 1 min.
1.2 Test conditions: Ta: 25 degrees Celsius; RH: indoor humidity.
1.3 Test circuit:
1.4 Description:
1.4.1 Voltage test is mainly to prevent electrical damage, through the input string of high voltage, affect the safety of users.
1.4.2 During the test, the voltage must be increased from 0V and reached the highest point within 1 minute.
1.4.3 Pay attention to the Timer setting of the tester when discharging, and switch the voltage back to 0V before OFF.
1.4.4 During the safety certification test, the transformer shall be separately measured. The temperature shall be 25 degrees Celsius, RH: 95 degrees Celsius, 48HR, and the transformer primary/secondary and primary /CORE shall be tested later.
1.4.5 Production line test time is 1 second.
2. Ripple noise (ripple noise voltage) testing
2.1 Definition:
Maximum (P-P) or effective value of the AC voltage component overlapped over DC output voltage.
2.2 Test conditions:
I/P: Nominal
O/P : Full Load
Ta: 25 ℃
2.3 Test circuit:
2.4 Test waveform:
2.5 Description:
2.5.1 The shorter the oscilloscope GND line, the better. The test line should be far away from the PUS.
2.5.2 Using a 1:1 Probe.
2.5.3 The Scope's BW is generally set at 20MHz, but it is better to set the BW to the maximum for the ripple noise of the current network products.
2.5.4 Noise and the use of the instrument, the environment is very different, so the test must indicate the test location.
2.5.5 Test ripple noise shall not exceed the original specification value +1%Vo.
3. Leakage current testing.
3.1 Definition:
Input the current flowing between the chassis (the chassis must be grounded).
3.2 Test conditions:
I/P: Vin Max) x 1.06 (TUV) / 60 hz
Vin max.(UL1012)/60Hz
O/P: No Load/Full Load
Ta: 25 ℃
3.3 Test circuit:
3.4 Description:
3.4.1 Both L and N need to be measured.
3.4.2 UL1012 R value is 1K5 and TUV R value is 2K/0. 15 uf.
3.4.3 Leakage current Specifications TUV: 3. 5 ma, UL1012:5 ma.