Specifications
Brand Name :
KHJ
Model Number :
KDP07
Certification :
ATEX,IECEx,CE,RoHS
Place of Origin :
Guangdong, China
MOQ :
1 pcs
Price :
Negotiable
Payment Terms :
L/C, T/T
Supply Ability :
500pcs/day
Delivery Time :
3-8work days
Packaging Details :
Negotiable
Product name :
KDP07 Series Explosion proof Control circuit
Enclosure material :
Aluminum alloy enclosure, powder coated, Industrial grey with dark lines texture (RAL7035)
Exposed fasteners :
Stainless steel
Rated voltage :
Maximum 415V AC
Rated current :
Maximum 200A
Frequency :
50Hz/60Hz
Degree of protection :
IP66
Ambient temperature :
-20℃~+60℃, -40℃~+60℃
Description

KDP07 Series Explosion Proof Electrical Equipment Explosion Proof Control Circuit

Application and Features:

● Explosion protection
- IECEx (IEC)-IECEx TPS 18.0025X
- ATEX (CENELEC,EN)-TPS 19 ATEX 003086 0005 X Rev. 00
- China Ex(GB)
● Application in hazardous area
Zone 1 and Zone 2,
Zone 21 and Zone 22
● Three types of explosion protection: Ex db IIB, Ex db IIB+H2, Ex tb IIC
● The enclosure can be equipped with transformers, buttons, indicator lights, switches,potentiometers, voltmeters, ammeters, tachometers, etc.
● The emergency stop button can be equipped with an anti-misoperation mechanism and a padlock by requirements.
● The enclosure with hinges and handle, convenient for installation and maintenance.Protect the flame-proof surface when operating.
● The enclosures can be combined and installed to meet the various requirements of power distribution systems.
● Can be customized according to user requirements, meet the certificate use restrictions.
● The number of elements and the maximum number of holes size needs to meet the requirements of power dissipation and mechanical strength of the housing.
● The circuit breaker using metal handle with frozen-resistant and can be equipped with a padlock.
● Please specify the special requirements when ordering.
Note:
1. Optional components:
K0105 explosion-proof switch button(1NO&1NC as default)
K0106 explosion-proof indicator,
K0109 explosion-proof ammeter,
2. Example: KDP07-A2B1K1
Components: 2 buttons, 1 ammeter, 1 control switch
Details: 1 start button (HL0105-A1I01, 1NO+1NC);
1 stop button (HL0105-A1I21,1NO+1NC);
1 ammeter (50/5);
1 control switch (stop-run-start);
3. The rain shade is customizable by requirements.

Technical Parameter:

Ex marking Gas Il2 G Ex db IIB T6 Gb Ex db IIB T6 Gb Ex d IIB T6 Gb
II2 G Ex db[ ia/ib] IIB T6 Gb Ex db[ ia/ib] IIB T6 Gb Ex d[ ia/ib] IIB T6 Gb
II2 G Ex db IIB+H2 T6 Gb Ex db IIB+H2 T6 Gb Ex d IIB+H2 T6 Gb
II2 G Ex db[ia/ib] IIB+H2 T6 Gb Ex db[ia/ib] IIB+H2 T6 Gb Ex d[ia/ib] IIB+H2 T6 Gb
Dust II2 D Ex tb IIIC T80℃ Db Ex tb IIIC T80℃ Db Ex tD A21 IP66 IIIC T80℃
Conformity to standards

IEC 60079-0, IEC 60079-1, IEC 60079-11, IEC 60079-31

EN 60079-0, EN 60079-1, EN 60079-11, EN 60079-31 GB3836.1,GB3836.2,GB12476.1,GB12476.5

Enclosure materials Enclosure Aluminum alloy enclosure, powder coated, Industrial grey with dark lines texture (RAL7035)
Transparent part Tempered glass, resistant to 4J impact
Rain shade Bended steel plate surface powder coated, industrial grey with dark lines texture (RAL7035) or stainless steel 304/316, please note when needed
Exposed fasteners Stainless steel
Components K0105 explosion-proof switch button
K0106 explosion-proof indicator
K0107 explosion-proof indicator
Control switch
Specifications of potentiometer according to requirements
The voltmeter, ammeter and tachometer are 48/72 type, specifications according to requirements
Rated voltage Maximum 415V AC
Rated current Maximum 200A
Frequency 50Hz/60Hz
Maximum dissipation power

Enclosure size

Temperature

Type class

Ta:+40℃ Ta:+60℃ The weight of Empty enclosure
T6/T80℃ T6/T80℃
105X105X90 01.1 ≤10A ≤16A 1.1kg
105X160X90 01.2 ≤10A ≤16A 1.5kg
116X202X90 01.3 ≤10A ≤16A 2.6kg
282X210X170 03 45W 45W 9.0kg
350X210X170 07 45W 45W 11.5kg
350X300X235 08 45W 45W 16.6kg
433X350X280 11 100W 100W 26kg
563X433X280 15 132W 132W 48kg
720X563X280 19 201W 201W 85kg
720X563X350 21 210W 210W 95kg
Degree of protection IP66
Ambient temperature -20℃~+60℃, -40℃~+60℃
Cable entry M□X1.5(default, exact size according to requirement) , NPT thread (optional)
Inlet direction Bottom in and bottom out
Installation method Wall type (default)
Stand type (optional)

Outline and Installation Dimension(Dimensions in mm):

IP66 max. 415VAC Explosion Proof Electrical Equipment Control Circuit KDP07 Series

Send your message to this supplier
Send Now

IP66 max. 415VAC Explosion Proof Electrical Equipment Control Circuit KDP07 Series

Ask Latest Price
Brand Name :
KHJ
Model Number :
KDP07
Certification :
ATEX,IECEx,CE,RoHS
Place of Origin :
Guangdong, China
MOQ :
1 pcs
Price :
Negotiable
Contact Supplier
IP66 max. 415VAC Explosion Proof Electrical Equipment Control Circuit KDP07 Series

Shenzhen KHJ Semiconductor Lighting Co., Ltd

Active Member
4 Years
shenzhen
Since 2009
Business Type :
Manufacturer, Exporter, Seller
Total Annual :
50000000-100000000
Employee Number :
400~500
Certification Level :
Active Member
Contact Supplier
Submit Requirement