Ex marking | Gas | Il2 G Ex db IIB T6/T5/T4 Gb | Ex db IIB T6/T5/T4 Gb | Ex d IIB T6/T5/T4 Gb | |||||||
II2 G Ex db IIB+H2 T6/T5/T4 Gb | Ex db IIB+H2 T6/T5/T4 Gb | Ex d IIB+H2 T6/T5/T4 Gb | |||||||||
Dust | II2 D Ex tb IIIC T80/T95/T130℃Db | Ex tb IIIC T80/ T95/T130℃Db | Ex tD A21 IP66 T80/T95/T130℃ | ||||||||
Conformity to standards | IEC 60079-0, IEC 60079-1, IEC 60079-31 EN 60079-0, EN 60079-1, EN 60079-31 GB3836.1,GB3836.2,GB12476.1,GB12476.5 | ||||||||||
Enclosure material | Enclosure | Aluminum alloy enclosure, powder coated, industrial gray with dark lines texture(RAL7035) | |||||||||
Exposed fastener | Stainless steel | ||||||||||
Components | Brand of terminal | International brand | |||||||||
Rated voltage | Max. 1000V AC, 1500V DC | ||||||||||
Rated current | Max. 1200A | ||||||||||
Frequency | 50Hz/60Hz | ||||||||||
Maximum dissipation power |
Enclosure size |
Type | Ta:+60℃ | Ta:+40℃ | Weight of empty enclosure | ||||||
T6/T80℃ | T5/T95℃ | T4/ T130℃ | |||||||||
Power | Rated current | Power | Rated current | Power | Rated current | ||||||
282X210X170 | 03 | 45W | ≤63A | 110W | -- | 110W | -- | 9.0kg | |||
350X210X170 | 07 | 45W | 63A~100A | 80W | -- | 139W | -- | 11.5kg | |||
350X300X235 | 08 | 45W | 63A~100A | 80W | -- | 139W | -- | 16.6kg | |||
433X350X280 | 11 | 100W | 100A~250A | 288W | -- | 288W | -- | 26kg | |||
563X433X280 | 15 | 130W | 250A~400A | 365W | 400A~800A | 365W | 800A~1200A | 48kg | |||
720X563X280 | 19 | 200W | 250A~400A | 448W | 400A~800A | 448W | 800A~1200A | 85kg | |||
720X563X350 | 21 | 210W | 250A~400A | 690W | 400A~800A | 690W | 800A~1200A | 95kg | |||
Degree of protection | 03,07,08,11,15--IP66/IP67 19,21--IP66 | ||||||||||
Ambient temperature | -20℃~+40/60℃, -40℃~+40/60℃ | ||||||||||
Cable entries | Standard M□*1.5(Upon request),NPT thread (Optional) | ||||||||||
Inlet direction | Upon request | ||||||||||
Installation Method | Hanging type (Standard) | ||||||||||
Floor type (Optional) |
Selection Table(Dimensions in mm):
Enclosure specifications | Guideway×Terminal (specification and quantity) | ||||||||||
2.52 | 42 | 62 | 102 | 162 | 352 | 702 | 1202 | 1852 | 2402 | 3002 | |
UK3N | UK5N | UK6N | UK10N | UK16N | UK35N | / | / | / | / | / | |
SAK2.5EN | SAK4EN | SAK6EN | SAK10EN | SAK16EN | SAK35EN | / | / | / | / | / | |
03 | 1X23 | 1X21 | 1X18 | 1X14 | 1X12 | / | / | / | / | / | / |
07 | 1X31 | 1X29 | 1X24 | 1X19 | 1X16 | / | / | / | / | / | / |
08 | 1X32 | 1X30 | 1X25 | 1X20 | 1X18 | / | / | / | / | / | / |
11 | 1X45 | 1X40 | 1X34 | 1X28 | 1X24 | 1X16 | / | / | / | / | / |
2X45 | 2X40 | 2X34 | 2X28 | / | / | / | / | / | / | / | |
15 | 1X60 | 1X54 | 1X48 | 1X36 | 1X30 | 1X20 | / | / | / | / | / |
2X60 | 2X54 | 2X48 | 2X36 | 2X30 | / | / | / | / | / | / | |
19 | 1X90 | 1X80 | 1X70 | 1X60 | 1X40 | 1X25 | 1X25 | 1X14 | 1X10 | 1X8 | 1×X5 |
2X90 | 2X80 | 2X70 | 2X60 | 2X40 | / | / | / | / | / | / | |
21 | 1X90 | 1X80 | 1X70 | 1X60 | 1X40 | 1X25 | 1X25 | 1X14 | 1X10 | 1X8 | 1X5 |
2X90 | 2X80 | 2X70 | 2X60 | 2X40 | / | / | / | / | / | / |