This user manual covers the range of ATEX and IECEx Tank Series LED normal/emergency luminaire. These luminaires are constructed with corrosion resistant epoxy coated aluminum alloy body and high impact resistance tempered glass diffuser.
Tank Series Two Luminaires Assembly LED are available from 240W to 360W, providing ideal solutions for a wide range of harsh and hazardous applications.
Features And Benefits:
1. High efficacy LED Source with long lifespan>100,000 hours
2. 5-year performance warranty
3. Low THD around 10%,Less interference
4. 6KV Surge Protection
5. Robust aluminium housing and strong tempered glass
6. Vibration and shock resistant
7. Low maintenance
8. Dust proof structure design to avoid dust accumulation
Product Important Information:
Type Of Protection | Ex db ,Ex tb | ||
Protection Standards | (IEC)EN 60079-0, (IEC)EN 60079-1, (IEC)EN 60079-28, (IEC)EN 60079-31 EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, EN 60598-1, EN 60598-2-5, EN 62031, EN 62493, IEC 62321-4, IEC 62321-5, IEC 62321-6, IEC 62321-7-1, IEC 62321-7-2, IEC 62321-8 | ||
Area Classfiction | Zone 1 and Zone 2 Areas to (IEC)EN 60079-10-1, Zone 21 and Zone 22 Areas to (IEC)EN 60079-10-2 | ||
Installation | (IEC)EN 60079-14 | ||
Certificate | |||
Equipment Coding | II 2 G Ex db IIC T* Gb II 2 D Ex tb IIIC T* Db IP66 | ||
Temperature Class | Rated power (W) | -40℃ ≤ Ta ≤ +55℃ | |
Gas | Dust | ||
160W~240W | T5 | T95℃ | |
ATEx Coding | ![]() | ||
Ingress Protection | IP66 (IEC)EN 60529 | ||
Cable entry | M20*1.5,M25*1.5,3/4 NPT | ||
CE Mark | The CE marking of this product applies to EU directives 2014/35/EU, 2014/30/EU, 2012/19/EU , 2011/65/EU and 2014/34/EU respectively. The Equipment is declared to meet the provisions of the ATEX directive(2014/34/EU)by reason of the EC Type Examination and compliance with the Essential Health and Safety Requirements |
Electrical Supplies:
Size:426*348*145mm | |||
Voltage Range(AC) | 100-277VAC (standard) | ||
Frequency Range(Hz) | 50/60Hz | ||
Power Watts(W) | 160W | 200W | 240W |
Standard Current Range(A) | 0.57~1.6 | 0.72~2.0 | 0.86~2.4 |
Emergency parameters | |
Voltage Range (AC) | 220~240VAC |
Battery | 9.6V 4.0Ah, Ni-MH |
Emergency Duration | ≥180minute |
Emergency power | 10W |
Charge time | ≥24hours |
Applications:
1. Oil&Gas Exploration
2. Drilling
3. Oil Refinery
4. Petrochemical Plant
5. Power Plant
6. Pharmaceutical Plant
Ordering Information
P/N | Operating Voltage(V) | Luminous Flux(lm) | Power(W) | CRI | Color Temp. | CCT(K) | Temp. Classification |
Ex-KTK160**CH-P2-E |
100-277 VAC (141-392 VDC) | 22910 |
160 | 70 | Cool white | 5700K±300K | T5 |
Ex-KTK160**NH-P2-E | 22910 | 70 | Natural white | 5000K±300K | T5 | ||
Ex-KTK160**NH-P2-E | 22910 | 70 | Natural white | 4000±300k | T5 | ||
Ex-KTK160**WM-P2-E | 20619 | 70 | Warm white | 3000±300k | T5 | ||
Ex-KTK200**CH-P2-E | 29145 |
200 | 70 | Cool white | 5700±300k | T5 | |
Ex-KTK200**NH-P2-E | 29145 | 70 | Natural white | 5000±300k | T5 | ||
Ex-KTK200**NH-P2-E | 29145 | 70 | Natural white | 4000±300k | T5 | ||
Ex-KTK200**WM-P2-E | 26230 | 70 | Warm white | 3000±300k | T5 | ||
Ex-KTK240**CH-P2-E | 34136 |
240 | 70 | Cool white | 5700±300k | T5 | |
Ex-KTK240**NH-P2-E | 34136 | 70 | Natural white | 5000±300k | T5 | ||
Ex-KTK240**NH-P2-E | 34136 | 70 | Natural white | 4000±300k | T5 | ||
Ex-KTK240**WM-P2-E | 30884 | 70 | Warm white | 3000±300k | T5 |
Remarks:
1.The first * stands for Operating Voltage including default-100 - 277 VAC , D-347-480VAC ,E-20-30VAC.
2.The second * stands for Candela Distribution including H3V3,H5V5,H6V6.
What are our advantages?
1.Professional lighting manufacturer for more than 10 years.
2. Gold supplier.
3. Provide high quality products and best service.
4. Good production capacity and fast delivery.