cri>80 300*1200mm flat led panel,dali dimmable panel,Dali dimming panel fixture
Our advantages of Dimmable led panel
Conforming to CE & RoHs.
Environment-friendly and no UV or IR radiation.
Extruded aluminum is good at heat dissipation, surface temperature usually stay below 65°.
Wide range of available operating voltage and low consumption.
Electrical Data | |
Rated wattage | 36W |
Nominal wattage | 37W |
Nominal voltage | AC 100-277V |
Power factor λ | 95% |
Operating frequency | 50-60 Hz |
Energy consumption | 35kWh/1000h |
Light technical data
Nominal luminous flux | 3100 lm |
Rated luminous flux | 3000lm |
Color temperature | 4000-4500k |
Light color as per EN 12464-1 | Natural white |
Color rendering index CRI | 83 |
Standard deviation of color matching | ≤3 sdcm |
Starting time | ≤0,1 s |
Warm-up time (60 %) | 0,0 s |
Lumen main. fact. at end of nom. life time | 70 % min. |
Lumen maintenance at end of service life | 70 % min. |
Farben & Materialien | |
mercury and lead-free | Yes |
Nominal lamp life time | 50,000 hours |
Rated lamp life time | 40,000 hours |
Switching cycles (on/off) | 100,000 |
Additional factor
Installation type | Recessed/Suspended/Surface mounting |
Capabilities | |
Dimmable (standard power adapter) | No |
Dimmable (dimmable power adapter) | Yes |
Certificates & standards
Energy efficiency class | A+ |
Dimensions | |
Actual Size | 295*1195mm |
Thickness | 10mm |
Packing Size | 5pcs/CTN G.W:25KGS |
G.W | 4.7kgs |
How to install the dali dimmable flat panel into the traditional fixtures?
1).Cut off the power.
2).Remove the existing component reflector and ballast.
3). Put the driver in the place of the previous ballast.
4). Remove the plastic cover from the LED head.
5). Mount the LED retrofit kit into the socket.
6).Connect the electric wires
Trailing edge dimmers (as opposed to leading edge, or triac dimmers) turn off the electrical load at the end, or trailing edge, of the AC input waveform. They control the power to the load by varying the duty cycle (the ratio of on time to on+off time) of the voltage to the load, the same as leading edge or triac dimmers. Cutting off the trailing edge of the waveform allows compatibility with electric loads that are either resistive or capacitive in nature (as opposed to leading edge dimmers which are compatible with resistive and inductive loads). Trailing edge dimmers are more complex than other dimmers, and are usually implemented using back-to-back power FETs (n-channel enhancement-mode MOSFETS with their source terminals connected together, the gates connected together, and the drain terminals acting as the two power terminals). The FETs have an intrinsic body diode which means they always conduct in one direction. Putting two FETs together as described allows current flow to be controlled in either direction (with no gate signal, both FETs are off, and the body diodes allow no current flow either. If one FET is gated on, the current can flow through that FET and the body diode of the other FET).
Trailing edge dimmers are designed to fade the voltage to zero rather than switch it abruptly off, by applying a resistance to create a ramp rather than a "cliff." This greatly reduces interfering electrical and radio emissions. It also increases the amount of heat dissipated, since the resistive period generates heat. Most trailing edge dimmers contain thermal monitors that can adjust the ramp if too much heat is being generated.