Mean Well PLC-100 Series 96 - 264V 100W Class 2 PFC Single Output Switching LED Power Supply
Features and Benefits:
● Universal AC input / Full range
● High iefficiency up to 88.5%
● Protections: Short circuit / Over current / Over voltage / Over temperature
● Cooling by free air convection
● Built-in active PFC function
● Fully isolated plastic case with terminal block styles of I/O
● Pass LPS
● Class 2 power unit
● 100% full load burn-in test
● High reliability
● Suitable for dry / damp locations
● Suitable for LED lighting and moving sign applications (Not.2)
● Compliance to worldwide safety regulations for lighting
● Pass LPS, UL,CE,ROHS
● 2 Years Warranty
Technical Specification:
MODEL | PLC-100-12 | PLC-100-15 | PLC-100-24 | PLC-100-36 | |
OUTPUT | DC VOLTAGE | 12V | 15V | 24V | 36V |
CONSTANT CURRENT REGION | 9-12V | 11.2-15V | 18-24V | 27-36V | |
RATED CURRENT | 5A | 5A | 4A | 2.65A | |
CURRENT RANGE | 0~5A | 0~5A | 0~4A | 0~2.65A | |
RATED POWER | 60W | 75W | 96W | 95.4W | |
RIPPLE&NOISE(max.) Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE | 10.2~12V | 12.8~15V | 20.4~24V | 30.6~36V | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±3.0% | ±3.% | ±2.0% | |
LINE REGULATION | ±1% | ±1% | ±1% | ±1% | |
LOAD REGULATION | ±2% | ±2% | ±2% | ±2% | |
SETUP,RISE TIME | 500ms, 80ms/230VAC ,1200ms, 80ms/115VAC at full load | ||||
HOLD UP TIME(Typ.) | 60ms/230VAC 16ms/115VAC at full load | ||||
INPUT | VOLTAGE RANGE | 90~264VAC ,127~370VDC | |||
FREQUENCY RANGE | 47~63Hz | ||||
EFFICIENCY (Typ.) | 83% | 88.5% | 88.5% | 88% | |
AC CURRENT (Typ.) | 12V:0.8A/115VAC ,0.4A/230VAC | ||||
LEAKAGE CURRENT | <2mA / 240VAC | ||||
PROTECTION | OVERLOAD | 11~150% rated output power | |||
Protection type:shut down o/p voltage, re-power on to recovery | |||||
OVER VOLTAGE | 13~16V | 16.5~20V | 27~34V | 39-48V | |
Protection type:shut down o/p voltage, re-power on to recovery | |||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | ||||
ENVIRONMENT | WORKING TEMP. | -10~+60℃ (Refer to "Derating Curve") | |||
WORKING HUMIDITY | 20~90% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40~+85℃, 10~95% RH | ||||
TEMP. COEFFICIENT | ±0.05% / ℃ (0~50℃) | ||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||
SAFETY | SAFTY STANDARDS | UL1310 approved | |||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,O/P-FG:100M Ohms / 500VDC /25℃ / 70% RH | ||||
OTHERS | MTBF | 297K hrs min. MIL-HDBK-217 (25℃) | |||
DIMENSION | 200.5*69.5*35MM (L*W*H) | ||||
PACKING | 0.52Kg: 25PCS/14Kg/0.65CUFT | ||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. |