HVA-12100Z1 (12V), HVA-24100Z1(24V) 12V or 24VDC 100W Output Isolated Design IP67 Waterproof LED Power Supply with 90 ~ 264VAC input
Features:
* Isolated design, safe and reliable
* 90~264VAC input voltage
* IP67 waterproof grade, suitable for indoor and outdoor installation and use
* 100% full load burn-in test
* Cooling by free air convection
* Protections: Short circuit/Overload/over voltage/over temperature
* Low cost, high reliability
* Output Voltage 12V and 24VDC for indoor damp location and outdoor Lighting use ;
* Conforms to the EMC conduction radiation standard (EN61000, EN55015)
* High quality and Cost saving
* 3 Years warranty
* CE,RoHs certificates
MODEL | HVA-12100Z1 | HVA-24100Z1 | |
OUTPUT | DC Voltage | 12V±0.5V | 24V±0.5V |
Rated Current | 8.33A | 4.17A | |
Rated Power | 100W | 100W | |
Ripple & Noise | ≤300mVpp | ≤500mVpp | |
Hold up time | ≤2s | ||
INPUT | Voltage Range | 90~264VAC | |
Frequency Range | 50/60Hz | ||
Input Current | ≤2.73A(12VDC) ,≤2.69A(24VDC) | ||
Power Factor | PF≥0.95 | ||
Efficiency | ≥83% | ≥85% | |
Inrush current | Cold Start:40A/230VAC | ||
Leakage Current | ≤0.75mA/240VAC | ||
Protection | Over Loading | 120~150% | |
Short Circuit | Protection type: Hiccup mode, recovers automatically after fault condition is removed. | ||
Over heat | 85℃±10℃ Shut down, repower on to recover) | ||
Voltage Resistance | Input-Output | AC 1.5KV/5mA 5s | |
Input-Housing | AC 1.5KV/5mA 5s | ||
Environment | Working Temp. | -25℃~+40℃ | |
Working Humidity | 10-90% RH non-condensing | ||
Storage Temp. | 40℃~+60℃,10~95%RH | ||
Cables | Input | VDE H03VVF 3G0.75mm² Black *200mm | |
Output | VDE H03VVF 2*0.75mm² White *200mm | ||
Others | Housing Material | Aluminum Housing | |
IP Rating | IP67 | ||
Dimension | L213*W68*H39mm | ||
Packing | 9kg/10pcs/Carton | ||
Notes | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. | ||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | |||
3. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. | |||
4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. | |||
5. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes. |
Mechanical Specification:
Packing Information: