Technical Parameters
Technical Parameters |
Model No. | Leeb222 |
Measuring principle | Fe & NFe |
Measuring range (µm) | 0~1250μm |
Probe | Changeable |
Shell | Plastic |
Accuracy | ±(1~3%H+1) μm; H refers to the thickness of testing piece |
Minimum resolution (µm) | 0.1μm |
Min curvature of the min area (mm) | Convex1.5 Concave9 |
Diameter of the min area (mm) | Φ7 |
Critical thickness of substrate (mm) | 0.5 |
Memory | 200 grops measured data |
Dimensions | 115*70*30mm |
Power supply | AAA Alkaline battery |
Standard Configuration | Main Machine, 2 probe substrate, 5 Calibration specimens |
Optional Accessories | Probes,Specimens |
Measuring Principle
a) Magnetic method (F Probe)
Measuring Non-magnetic coatings on magnetic substrates (such as aluminum,chromium, copper, rubber coatings on steel, iron, alloy and hard magnetic steel substrates).
b) Eddy current method (N Probe)
Measuring Non-conductive coatings on Non-magnetic basis metals (such as enamel, plastic, rubber, paint coatings on copper, aluminum, zinc, tin substrates).
Working Mode(Directly & Groups)
(1) Directly──This method is used for randomness, measured values exist memory unit(99 storage unit).When 99 full storage unit,the new measurements will set off the measured value of the old,That is always the latest 99 measurements included in the statistics.
(2) Group──This way is convenient for user to batch record test data,a group of at most 99 value,a total of 15 group,can save 495
value.When 99 full value in each group,Measuring frequency of the screen will show "99" ,At this time, still can be measured, but measurements show only are not stored,Not included in the statistics.When needed, can delete the group data, and then to new measurements.
Each group with a calibration value so that this group of individual data are based on the calibration values measured.Each group can be set up within the limit, then the measuring results of the group beyond the boundaries of annotation and report to the police.Group mode, each measured values are automatically included in the statistics.Because group mode can store a few sets of measurement data based on different calibration value, thus it particularly suitable for field measurement.
NOTE:All measurements will be included in the statistics(Program does not apply to F1/90 ℃ 90 ℃ and N1 / probe).
Standard Configuration and High Quality Equipment Box