ECOLITE Smart Battery Management System 600A Cusomized For 5-6Ah Starter Batteries
FEATURES
Support for 2Ah,3Ah,4Ah,5Ah,7Ah series batteries
The peak starting current was 250A,500A,600A,700A.
Technical parameters | |||||||
Function | Test project | Specifications | Unit | ||||
Min | Typical values | Max | |||||
Charging protection | Overcharge protection voltage | 3.85 | 3.90 | 3.95 | V | ||
Overcharge protection delay time | 800.00 | 1000.00 | 1400.00 | mS | |||
Overcharge protection restores voltage | 3.75 | 3.80 | 3.85 | V | |||
Discharge protection | Overdischarge protection voltage | 1.95 | 2.00 | 2.05 | V | ||
Overdischarge protection delay time | 800.00 | 1000.00 | 1400.00 | mS | |||
Overdischarge protection restores voltage | 2.35 | 2.40 | 2.45 | V |
Technical parameters | |||||||
Function | Test project | Specifications | Unit | ||||
Min | Typical values | Max | |||||
Overcurrent protection | Charging overcurrent protection value | / | / | / | A | ||
Charging overcurrent delay | / | / | / | mS | |||
Charging overcurent release recovery conditions | Disconnect the charger | ||||||
Discharge overcurrent 1 protection value | 570 | 600 | 630 | A | |||
Discharge overcurrent 1 protection delay | 640 | 700 | 825 | mS | |||
Discharge overcurrent protection value 2 | 1140 | 1200 | 1260 | A | |||
Discharge overcurrent 2 protection delay | 78 | 90 | 105 | mS | |||
Recovery conditions for discharge overcurrent protection | Disconnect load |
Technical parameters | |||||||
Function | Test project | Specifications | Unit | ||||
Min | Typical values | Max | |||||
Short circuit protection | Short circuit protection delay time | 220 | 400 | 610 | uS | ||
Short circuit protection recovery | Disconnect load |
Technical parameters | |||||||
Function | Test project | Specifications | Unit | ||||
Min | Typical values | Max | |||||
Balance function | Balanced turn-on voltage | / | 3.60 | / | V | ||
Balanced shutdown voltage | / | 3.59 | / | V | |||
Equilibrium mode | Passive equilibrium | ||||||
Equalizing current | 15 | 20 | 25 | mA |
Technical parameters | |||||||
Function | Test project | Specifications | Unit | ||||
Min | Typical values | Max | |||||
Temperature protection | Charging high temperature protection value | 72 | 75 | 78 | ℃ | ||
Charging high temperature protection release value | 65 | 70 | 75 | ℃ | |||
Low temperature protection value for charging | -13 | -10 | -7 | ℃ | |||
Low temperature protection release value during charging | / | -9 | / | ℃ | |||
High temperature protection value for discharge | 72 | 75 | 78 | ℃ | |||
Discharge high temperature protection release value | 65 | 70 | 75 | ℃ | |||
MOS over temperature protection value | 87 | 90 | 93 | ℃ | |||
MOS over temperature recovery value | 80 | 85 | 90 | ℃ |
Technical parameters | |||||||
Function | Test project | Specifications | Unit | ||||
Min | Typical values | Max | |||||
Self consumption power | Working mode | / | / | 220 | uA | ||
Operation temperature | Normal working range | -40 | / | 95 | ℃ | ||
Size(L*W*D) | 124mm*64mm*15mm |
Product wiring diagram
Q: Do you provide free sample?
A: Yes, a few pcs free sample can be provided, but freight will be charged
Q: what is the warranty?
A: one year
Q: What is your payment term?
A: T/T,L/C
Q: do you accepte OEM order?
A: Yes, you can print yourself logo, also we can provide the design of outlook for your special battery pack
Q: How many cells you can produce per month?
A: 1.8million
Q: What is the mode of transport?
A: usually by sea
Q: Which certificates do you have
A: We have un38.3,MSDS...etc.
Fill out our short form and we will be contacting you shortly to see we how can provide a solution to your needs!