Our 241kWh is an advanced and high-integration energy system. The system is designed in a battery cabinet and a control cabinet, where both the power(kW) and storage capacity (kWh) can be expanded to 482kWh/964kWh/723kWh/964kWh.
BATT-CI-100/241 series are widely used in various scenarios of industrial and commercial energy storage, coveringindustrial parks, supermarket, hotel, office building, data centers, solar charging staƟ on, microgrids and other fields.They reduced electricity costs, improved energy efficiency,and ensured the conƟ nued operaƟ on of criƟ cal equipment and business continuity.
Product features:
High Integration
Performance parameter
MODEL | BATT-CI-100/241 | BATT-CI-100/241-T | |
Type | 100kW/241kWh | 100kW/241kWh | |
System Parameters | |||
System Capacity | 241.15kWh | 241.15kWh | |
Battery specification | 768V 314Ah | 768V 314Ah | |
Cell | LFP Prismatic 3.2V314Ah | ||
Configuration | 241S1P | 240S1P | |
Nominal voltage | 768V DC | ||
Nominal capacity | 314Ah | 314Ah | |
Operating voltage range | 696V-852V DC | ||
Charge/discharge rate | 0.5C | ||
AC on-grid parameters | |||
Rate output power | 100kW | 100kW | |
Maximum output power | 105kW | 105kW | |
Output | 3W+N+PE | ||
AC Voltage | 380V/400V/ AC | ||
Voltage range | -15%~+10% | ||
Power factor adjustable range | -0.9(lead)~+0.9(lag) | ||
Frequency | 50/60Hz | ||
Output harmonics | <3%@Rated power | ||
AC off-grid parameters | |||
Rated output power | / | 100kW | |
Maximum output power | / | 105kW | |
AC standard | / | 3W+N+PE | |
Output haronics | / | <3%(Liner load) | |
AC voltage | / | 380V/400V AC | |
Frequency | / | 50/60Hz | |
Overload capacity | / | 105% continuous operation; (105%-120%):10min;(120%):stop operation | |
General parameters | |||
Dimensions(W*D*H) | BESS Cabinet | (1520*1480*2000mm)*1 | (1475*1105*2000mm)*1 |
Control Cabinet | / | (1475*1105*2000mm)*1 | |
Weight | 2.6T | 3.5T | |
Isolation mode | / | Isolation transformer(built-in) | |
On-grid and off-grid switching device | / | STS(electric switch) | |
Protection class | IP 55 | ||
Thermal management system | Perfluorohexanone | ||
Operating humidity range | 0%-90% non-condensing | ||
Operating temperature range | -20~55°C | ||
Maximum working altitude | 5000m(>3000m derating) | ||
Cycle life | ≥6000 cycles | ||
Communication interface | CAN/RS485 | ||
Communication protocol | Modbus-RTU,Modbus-TCP,CAN2.08 | ||
Standards Compliance | IEC62619 IEC61000 IEC62477 VDE4105 G98 G99 EN50549-1 BOS-P-01 C10/11 UN38.3 |