Specifications
Brand Name :
Schneider Electric
Model Number :
Vigi for Acti9
Certification :
CE,CCC etc.
Place of Origin :
China
MOQ :
12pcs
Price :
USD40~150/unit
Payment Terms :
T/T, Western Union
Supply Ability :
10,000pcs/month
Delivery Time :
5-8 working days
Packaging Details :
Standard export carton
Poles :
DPN, 2P, 3P, 4P
Ampere (A) :
10, 16, 20, 25, 32, 40, 50, 63
Voltage :
AC 230V / 400V
Standard :
IEC61009-1
Trip current :
30mA, 100mA etc.
Insulation :
Class 2
Type :
AC, A, SI
Material :
Engineering plastic of fire retardant
Install :
35mm DIN rail mount
Termminals :
Box/ screw
Description

Vigi for Acti 9 iC60 Schneider Electric Miniature Circuit Breaker DPN, 2P,3P,4P from 10 to 63A

Residual current add-on devices up to 63 A for Acti 9 iC60 Miniature Circuit Breakers

Miniature circuit breaker with overload protection is a kind of electric devices or advanced circuit breaker for both overload/short circuit protection plus earth leakage fault detection (Residual current device). It is widely used is applications from household to industries.

Part of 9 Series

Simple to install and ideal for all industrial and commercial buildings, the residual current add-on devices for Acti 9 iC60 provide you with leakage protection whilst ensuring a greater continuity of service.

Vigi for Acti 9 iC60 Schneider Electric Residual Current Circuit Breaker DPN, 2P,3P,4P from 10 to 63A

Vigi for Acti 9 iC60 Schneider Electric Residual Current Circuit Breaker DPN, 2P,3P,4P from 10 to 63A

  • Features

    Fully compliant with national standards and easy to install, the Acti 9 Vigi iC60 comes with a wealth of features:

    • Class-2 insulation: ensures continuous protection for both operators and unqualified personnel.

    • VISI-TRIP: quickly detects faulty outgoers and reduces intervention time.

    • Fully immune earth leakage protection: provides enhanced continuity of service, especially with the new “SI” (Super Immune) type for application in polluted environments and networks.

    • Easily connect to Acti 9 iC60 Miniature Circuit-Breakers (MCBs) either electronically or manually.

    • Nominal current ranges from 25 to 63 A.

    • Comes in “SI” (Super Immune), AC, and A types.

    • 30 mA sensitivity for additional protection against direct contact (in compliance with IEC 60364).

    • 100 mA, 300 mA, 500 mA and 1000 mA sensitivities for additional protection against fire and indirect contact (in compliance with IEC 60364).

    • “SI” (Super Immune) type: protects sensitive circuits (IT equipment) and those prone to disturbances (electronic ballasts for light fixtures, power electronics).

    • Selective type: guarantees selectivity to correctly distinguish between different residual current devices (RCDs) and trip the device closest to the fault.

    • Complies with IEC EN 61009-1 standard, certified by national authorities.

    • Acti 9 iC60 DIN rail miniature circuit breakers (MCBs) retain the same characteristics when combined with an Acti 9 Vigi iC60 DIN rail add-on residual current device (RCD).

    Vigi for Acti 9 iC60 Schneider Electric Residual Current Circuit Breaker DPN, 2P,3P,4P from 10 to 63A

    Vigi for Acti 9 iC60 Schneider Electric Residual Current Circuit Breaker DPN, 2P,3P,4P from 10 to 63A

    Vigi for Acti 9 iC60 Schneider Electric Residual Current Circuit Breaker DPN, 2P,3P,4P from 10 to 63A

    Vigi for Acti 9 iC60 Schneider Electric Residual Current Circuit Breaker DPN, 2P,3P,4P from 10 to 63A

    Vigi for Acti 9 iC60 Schneider Electric Residual Current Circuit Breaker DPN, 2P,3P,4P from 10 to 63A

    Benefits

    From adding protection to polluted environments and networks to ensuring a greater continuity of service, the Acti 9 Vigi iC60 also boasts impressive environmental credentials.

    • 100% earth leakage protection in final distribution.

    • Greater continuity of service with VisiTrip.

    • Greater electrical immunity with “SI” (Super Immune) type.

    • Meaningful part numbers make selection easy.

    • Easy to install with robust terminal connections.

    • Environmentally friendly, made with 100% recyclable and recoverable materials.

    Applications

    Ideal for installation in all industrial and commercial buildings, residual current add-on devices provide protection against:

    • Electrocution (in compliance with IEC 60364 installation standards and national standards).

    • Fire hazards caused by leakage currents flowing into building materials.

Vigi for Acti 9 iC60 Schneider Electric Residual Current Circuit Breaker DPN, 2P,3P,4P from 10 to 63A

Vigi for Acti 9 iC60 Schneider Electric Residual Current Circuit Breaker DPN, 2P,3P,4P from 10 to 63A

Main

range

Acti 9

product or component type

Add-on residual current devices

device short name

Vigi iC65

poles description

4P

[In] rated current

40 A

earth-leakage sensitivity

100 mA

earth-leakage protection time delay

Instantaneous

Earth leakage protection type

Type AC

network type

AC

network frequency

50/60 Hz

[Ue] rated operational voltage

230 V AC 50/60 Hz conforming to GB 16917.22

standards

GB 16917.22

9 mm pitches

4

Complementary

device location in system

Outgoer

residual current tripping technology

Voltage dependent

range compatibility

Acti 9 iC60
Acti 9 Reflex iC60

product compatibility

Single terminal

local signalling

Trip indicator

mounting mode

Clip-on

mounting support

DIN rail

electrical connection to mcb

By screws

height

91 mm

depth

73.5 mm

Environment

ambient air temperature for operation

-25…60 °C

Offer Sustainability

Sustainable offer status

Green Premium product

REACh Regulation

REACh Declaration

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Download RoHS China Declaration
Product out of China RoHS scope. Substance declaration for your information

Product name

residual current circuit breaker, operated circuit breakers, ED81 1 Pole Miniature Circuit Breaker, RCCB circuit breaker, mini rcbo

Rated frequency

50/60 Hz, 50Hz, 50 HZ/60HZ

Breaking capacity

4.5KA, 4KA/6KA, 6KA/10KA

Standard

IEC61008-1, IEC60947-2, GB14048.2/IEC60947-2, ISO9001, IEC60898-1/GB10963.1

Material

Copper, High Standard Plastic Silver Copper, Silver Contact, Flame Resistant Plastic, IP20

Color

White, White/green, decided by customer, White/Transparent, Black and white

Mechanical life

4000 Times, 20000 Times

Application

Short-circuit Protection, Electrical Power, earth leakage protection

Pole

2P, 4P

Endurance

4000

Curve type

C, B/C

Printing

Standard or customized, Customized

Protection degree

Housing IP40, IP 20

Rated operating voltage

400V

Vigi for Acti 9 iC60 Schneider Electric Residual Current Circuit Breaker DPN, 2P,3P,4P from 10 to 63A

Send your message to this supplier
Send Now

Vigi for Acti 9 iC60 Schneider Electric Residual Current Circuit Breaker DPN, 2P,3P,4P from 10 to 63A

Ask Latest Price
Brand Name :
Schneider Electric
Model Number :
Vigi for Acti9
Certification :
CE,CCC etc.
Place of Origin :
China
MOQ :
12pcs
Price :
USD40~150/unit
Contact Supplier
Vigi for Acti 9 iC60 Schneider Electric Residual Current Circuit Breaker DPN, 2P,3P,4P from 10 to 63A
Vigi for Acti 9 iC60 Schneider Electric Residual Current Circuit Breaker DPN, 2P,3P,4P from 10 to 63A
Vigi for Acti 9 iC60 Schneider Electric Residual Current Circuit Breaker DPN, 2P,3P,4P from 10 to 63A
Vigi for Acti 9 iC60 Schneider Electric Residual Current Circuit Breaker DPN, 2P,3P,4P from 10 to 63A
Vigi for Acti 9 iC60 Schneider Electric Residual Current Circuit Breaker DPN, 2P,3P,4P from 10 to 63A

Wuxi Fenigal Science & Technology Co., Ltd.

Verified Supplier
6 Years
jiangsu, wuxi
Since 2013
Business Type :
Manufacturer, Importer, Exporter, Trading Company
Total Annual :
5,000,000-6,000,000
Employee Number :
>100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement