TeSys Schneider Electric LC1D AC Contactor 3P, 4P 9A~95A,115~620A,AC-3 AC-1 24V,110V,230V,380V etc.
Characteristic
TeSys D Green extends the TeSys D range with new electronic coils that reduce energy consumption by 80% compared to TeSys D standard AC or DC coils.
The TeSys D Green contactor model is reduced by 90% and the selection and maintenance is more convenient.
The TeSys D Green contactor works with the TeSys LR9D electronic overload relay to reduce heat generation and energy consumption by up to 50%.
• Current range 09~620A;
• AC, DC control coil is optional (DC coil to 38A);
• Different types of starters are available: standard motor start contactors, reversible contactors, star-delta starters, autotransformer starters, etc.
• Optional connection: bolt connection (09~620A), ring terminal connection (09~38A), EverLink terminal connection (40~65A) for customer installation;
• Product Certification: CCC, CE, CCS;
Advantage
• Compact installation
> Contactors to 38A and protection components are only 45mm wide
> Surge suppressor installation requires no tools and can be inserted directly into the contactor without taking up more space
> Reversible contactor is only 90mm wide, mechanical interlocking does not take up extra space, installation takes almost no time
> Starter components provide pre-wired modules for quick and easy assembly
• Highly integrated
> to 100A contactor integration 1 normally open / 1 normally closed auxiliary contact
> DC coil with built-in bidirectional suppression diode
> Reversible contactor group with built-in bidirectional suppression diode
• Safe and reliable
> The main circuit and control circuit of the control and protection components are clearly distinguished
> Mirrored contact design that meets safety standards, ensuring 100 million reliable actions
> Protective cover prevents accidental contact of the contactor
• outstanding quality
> DC coils have a wide range of control voltages (0.7~1.25Uc)
> Strong earthquake resistance
> lower noise
> Increased terminal strength
• TeSysD 40-65A Everlink:
> Permanent torque, reliable installation
> Compact and space saving
> Easy to install, saves time
> Easy to maintain and save costs
Product Series | TeSys |
---|---|
product name | TeSys D |
product type | Contactor |
Product short name | LC1D |
Contactor application area | Squirrel cage motor for switching on and off normal start Applied to AC loads with a power factor greater than or equal to 0.95 |
Use category | AC-1 AC-3 AC-4 |
Number of poles | 3P |
Power pole contact composition | 3 NO |
Rated working voltage [Ue] | Power circuit: <= 300 V DC 25...400 Hz Power circuit: <= 1000 V AC |
Rated operating current [Ie] | 125 A 60 °C) on <= 440 V AC AC-1 for power supply circuits 95 A 60 °C) on <= 440 V AC AC-3 Applicable power circuit |
Motor power (kW) | 45 kW on 415...440 V AC 50/60 Hz (AC-3) 55 kW on 500 V AC 50/60 Hz (AC-3) 45 kW on 660...690 V AC 50/60 Hz (AC-3) 45 kW on 1000 V AC 50/60 Hz (AC-3) 15 kW on 400 V AC 50/60 Hz (AC-4) 25 kW on 220...230 V AC 50/60 Hz (AC-3) 45 kW on 380...400 V AC 50/60 Hz (AC-3) |
Motor power HP (UL / CSA) | 20 hp on 200/208 V AC 50/60 Hz for 3-phase motors 7.5 hp on 115 V AC 50/60 Hz for 1-phase motors 15 hp on 230/240 V AC 50/60 Hz for 1-phase motors 25 hp on 230/240 V AC 50/60 Hz for 3-phase motors 60 hp on 460/480 V AC 50/60 Hz for 3-phase motors 60 hp on 575/600 V AC 50/60 Hz for 3-phase motors |
Control loop characteristics | AC on 50/60 Hz |
Control loop voltage | 230 V AC 50/60 Hz |
Auxiliary contact type | 1 NO + 1 NC |
Rated impulse withstand voltage [Uimp] | 8 kV in accordance with IEC 60947 |
Overvoltage category | III |
Conventional heating current [Ith] | 10 A on <60 °C for signal circuit 125 A on <60 °C for power supply circuit |
Rated turn-on capability [Irms] | 140 A AC suitable signal circuit in accordance with IEC 60947-5-1 250 A DC suitable signal loop in accordance with IEC 60947-5-1 1100 A on 440 V applicable power supply circuit in accordance with IEC 60947 |
Rated breaking capacity | 1100 A on 440 V applicable power supply circuit in accordance with IEC 60947 |
Rated short-time withstand current [Icw] | 1100 A on <40 °C - 1 s for power supply circuit 135 A on <40 °C - 10 minutes for power circuit 800 A on <40 °C - 10 s for power supply circuit 400 A on <40 °C - 1 minute for power circuit 100 A - 1 s for signal circuits 120 A - 500 ms Applicable signal loop 140 A - 100 ms for signal circuits |
Fuses used with relays | 10 A gG Applicable signal circuit in accordance with IEC 60947-5-1 200 A gG on...<= 690 V with type 1 for power circuit 160 A gG on...<= 690 V with type 2 for power supply circuit |
Average impedance | 0.8 mΩ - Ith 125 A 50 Hz for power supply circuits |
Rated insulation voltage [Ui] | Power circuit: 600 V CSA certification Power circuit: 600 V UL certification Power circuit: 1000 V in accordance with IEC 60947-4-1 Signal loop: 690 V in accordance with IEC 60947-1 Signal loop: 600 V CSA certified Signal circuit: 600 V UL certification |
Electrical life | 1.2 kA2.s 95 A AC-3 Ue condition <= 440 V 1.3 kA2.s 125 A AC-1 Ue condition <= 440 V |
Power consumption per pole | 12.5 W AC-1 7.2 W AC-3 |
Safety cover | band |
Installation method | Base plate installation Rail mounting |
standard | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
certified product | LROS (Lloyds register of shipping) DNV GOST RINA CCC BV GL |
Wiring ability | Control circuit: Bolt fastening 2 Cable 1...2.5 mm2 cord Control circuit: Bolt fastening 1 Cable 1...2.5 mm2 cord Control circuit: Bolt fastening 1 Cable 1...4 mm2 cord without Control circuit: Bolt fastening 2 Cable 1...4 mm2 cord without Control circuit: Bolt fastening 1 Cable 1...4 mm2 hard wire without Control circuit: Bolt fastening 2 Cable 1...4 mm2 hard wire without Power circuit: Terminal 1 Cable 4...50 mm2 cord without Power circuit: Terminal 2 Cable 4...25 mm2 cord without Power circuit: Terminal 1 Cable 4...50 mm2 flexible cable Power circuit: Terminal 2 Cable 4...16 mm2 cord Power circuit: Terminal 1 Cable 4...50 mm2 Hard wire without Power circuit: Terminal 2 Cable 4...25 mm2 Hard wire without |
Tightening torque | Control circuit: 1.2 Nm Screwdriver with bolt Ø 6 flat Control circuit: 1.2 Nm Screwdriver with No 2 Phillips screw Power circuit: 9 Nm through the terminal with a screwdriver Ø 6 - Ø 8 flat Power circuit: 9 Nm through terminal hex type 4 mm |
Action time | 20...35 ms closed 6...20 ms break |
Safety and reliability | B10d = 1369863 Contactors with nominal load compliance in accordance with EN/ISO 13849-1 B10d = 20000000 mechanical load contactors comply with EN/ISO 13849-1 |
Mechanical life | 4 kA2.s |
Maximum operating frequency | 3600 times / hour on ... <60 °C |
Features
As the best selling line of contactors in the world, TeSys D offers multi-standard solutions, high reliability with long mechanical and electrical durability for different sizes, along with the most complete accessories in the industry.
TeSys D contactors leverage over 100 years of experience and innovation to control your motors.
Specifications:
Dimensions: 4 width sizes available to cover all ratings
TeSys D benefits a wide range of accessories for:
TeSys D contactors can offer quick simple setup, while maintaining a compact size. These contactors can provide multiple advantages, including:
Safety
Efficiency
Continuity of service
TeSys D contactors are primarily used in industry, infrastructure and building applications.