Specifications
Brand Name :
Lee&J. Power
Model Number :
LH-MEX20MD
Place of Origin :
China
MOQ :
3
Price :
negotiation
Payment Terms :
T/T, Western Union, PayPal
Supply Ability :
100 pcs available
Delivery Time :
1-2 working days
Packaging Details :
normal standard package
Color :
Black
Type :
Li-ion
Voltage :
11.1V
Capacity :
4500mAh
Weight :
330g
Size :
148 x 60 x 23 mm
Warranty :
12 months
Suitable For :
T5, T6, T8, vs-900, vs-600, Accutorr 3, Accutorr 7, DPM6, DPM7, Passport 12, Passport 17m, Passport 8, A Series
Description

11.1V 4500mAh Li-ion Monitor Battery For Mindray T5, T6, T8, vs-900, vs-600, Accutorr 3, Accutorr 7, DPM6, DPM7, Passport 12, Passport 17m, Passport 8, A Series

Product Information

Brand Lee&J. Power
Reference LH-MEX20MD
Color

Black

Type Li-ion
Capacity 4500mAh
Voltage 11.1V
Weight 330g
Size 148 x 60 x 23 mm
Warranty 12 months
Replace Code LI23S002A, M05-010002-6, 022-000008-00, 115-018012-00
Suitable For

T5, T6, T8, vs-900, vs-600, Accutorr 3, Accutorr 7, DPM6, DPM7, Passport 12, Passport 17m, Passport 8, A Series

Detail Image

11.1V 4500mAh Li-Ion Battery For Mindray T5 T6 T8 Monitor VS-900 Accutorr 7 DPM7

Function Test


1. If the patient monitor is installed with batteries, remove the batteries first.
2. Verify that the patient monitor works correctly when running powered form an AC source.
3. Insert two batteries per the procedures provided in the Operator’s Manual.
4. Remove the AC power cord and verify that the patient monitor still works correctly.
5. For the models (which this battery suitable for) only: Remove one battery and verify that the patient monitor continues to work
correctly. Verify that the patient monitor can also work independently from another battery.

Performance Test

Perform the test by referring to the Battery chapter in the Operator’s Manual and verify the operating time of the battery meets the product specification.

Power Supply Failures

Symptoms Possible Cause Corrective Action
Different battery
voltages
Battery failure Replace battery.
Cable defective or
poorly connected
1. Check that the cable between battery
interface board and power module is
correctly connected.
2. Check that cables and connectors are not
damaged.
Power board failure Replace the power board.
Battery capacity is too
low
Battery failure Replace battery.
Cable defective or
poorly connected
1. Check that the cable is correctly
connected.
2. Check that connecting cables and
connectors are not damaged.
Power board failure Replace the power board.
Battery cannot be
recharged
Battery failure Replace battery and recharge the replacement
battery. If the replacement battery can be
recharged, the original one fails.
Cable defective or
poorly connected
1. Check that cable between battery interface
board and power module is correctly
connected.
2. Check that cables and connectors are not
damaged.
Power board failure Replace power board
No +3.3 V output 1. Power supply
protected
2. Power board failure
1. Turn off the patient monitor then restart it.
2. If the problem remains, disconnect the AC
mains for 5 s and reconnect it, then restart
the patient monitor.
3. If the problem still remains, replace the
power board.
No +5.0 V output
No +12 V output

Product Description

This battery has been manufactured with high-quality components. It complies with every particular of the orginal manufacturer's regulations and is guaranteed against all manufacturing defects.

A margin of 0.1V difference in the voltage is negligible in batteries. Therefore, such a battery would still be perfectly compatible. If the capacity (mAh) of the replacement battery is higher than that of the original battery, this will allow for a longer usage time.

Contact US

Big wholesale order is acceptable and the price is negotiable, please contact us for details.
OEM is also welcome. Please tell us the details of the product you want, then we can design and customize it for you.

Do not hesitate to contact us anytime before and after your purchase. If you have any questions on your purchase, please let me know via "contact now" or by email. We will solve it for you.
We are committed to ensuring that you are completely satisfied with every transaction. 100% Satisfaction guaranteed !
We will reply your mail within 24 hours normally. sometimes have a little delay due to the weekends or holidays.
(we work from Monday to Friday (8-17:30 GTM+8)
If you can't get our mail after 48 hours, please check your spam or contact to us. If you email us and I will be on service of you until you are satisfied with your purchase.

Send your message to this supplier
Send Now

11.1V 4500mAh Li-Ion Battery For Mindray T5 T6 T8 Monitor VS-900 Accutorr 7 DPM7

Ask Latest Price
Brand Name :
Lee&J. Power
Model Number :
LH-MEX20MD
Place of Origin :
China
MOQ :
3
Price :
negotiation
Payment Terms :
T/T, Western Union, PayPal
Contact Supplier
11.1V 4500mAh Li-Ion Battery For Mindray T5 T6 T8 Monitor VS-900 Accutorr 7 DPM7
11.1V 4500mAh Li-Ion Battery For Mindray T5 T6 T8 Monitor VS-900 Accutorr 7 DPM7

Shenzhen Lee&Jack Power Technology Co.,Ltd

Active Member
8 Years
guangdong, shenzhen
Business Type :
Manufacturer
Certification Level :
Active Member
Contact Supplier
Submit Requirement