11.1V 4500mAh Li-ion Monitor Battery For Mindray T5, T6, T8, vs-900, vs-600, Accutorr 3, Accutorr 7, DPM6, DPM7, Passport 12, Passport 17m, Passport 8, A Series
Product Information
Brand | Lee&J. Power |
Reference | LH-MEX20MD |
Color | Black |
Type | Li-ion |
Capacity | 4500mAh |
Voltage | 11.1V |
Weight | 330g |
Size | 148 x 60 x 23 mm |
Warranty | 12 months |
Replace Code | LI23S002A, M05-010002-6, 022-000008-00, 115-018012-00 |
Suitable For | T5, T6, T8, vs-900, vs-600, Accutorr 3, Accutorr 7, DPM6, DPM7, Passport 12, Passport 17m, Passport 8, A Series |
Detail Image
Function Test
1. If the patient monitor is installed with batteries, remove the batteries first.
2. Verify that the patient monitor works correctly when running powered form an AC source.
3. Insert two batteries per the procedures provided in the Operator’s Manual.
4. Remove the AC power cord and verify that the patient monitor still works correctly.
5. For the models (which this battery suitable for) only: Remove one battery and verify that the patient monitor continues to work
correctly. Verify that the patient monitor can also work independently from another battery.
Performance Test
Perform the test by referring to the Battery chapter in the Operator’s Manual and verify the operating time of the battery meets the product specification.
Power Supply Failures
Symptoms | Possible Cause | Corrective Action |
Different battery voltages | Battery failure | Replace battery. |
Cable defective or poorly connected | 1. Check that the cable between battery interface board and power module is correctly connected. 2. Check that cables and connectors are not damaged. | |
Power board failure | Replace the power board. | |
Battery capacity is too low | Battery failure | Replace battery. |
Cable defective or poorly connected | 1. Check that the cable is correctly connected. 2. Check that connecting cables and connectors are not damaged. | |
Power board failure | Replace the power board. | |
Battery cannot be recharged | Battery failure | Replace battery and recharge the replacement battery. If the replacement battery can be recharged, the original one fails. |
Cable defective or poorly connected | 1. Check that cable between battery interface board and power module is correctly connected. 2. Check that cables and connectors are not damaged. | |
Power board failure | Replace power board | |
No +3.3 V output | 1. Power supply protected 2. Power board failure | 1. Turn off the patient monitor then restart it. 2. If the problem remains, disconnect the AC mains for 5 s and reconnect it, then restart the patient monitor. 3. If the problem still remains, replace the power board. |
No +5.0 V output | ||
No +12 V output |
Product Description
This battery has been manufactured with high-quality components. It complies with every particular of the orginal manufacturer's regulations and is guaranteed against all manufacturing defects.
A margin of 0.1V difference in the voltage is negligible in batteries. Therefore, such a battery would still be perfectly compatible. If the capacity (mAh) of the replacement battery is higher than that of the original battery, this will allow for a longer usage time.
Contact US
Big wholesale order is acceptable and the price is negotiable, please contact us for details.
OEM is also welcome. Please tell us the details of the product you want, then we can design and customize it for you.
Do not hesitate to contact us anytime before and after your purchase. If you have any questions on your purchase, please let me know via "contact now" or by email. We will solve it for you.
We are committed to ensuring that you are completely satisfied with every transaction. 100% Satisfaction guaranteed !
We will reply your mail within 24 hours normally. sometimes have a little delay due to the weekends or holidays.
(we work from Monday to Friday (8-17:30 GTM+8)
If you can't get our mail after 48 hours, please check your spam or contact to us. If you email us and I will be on service of you until you are satisfied with your purchase.