Specifications
Certification :
3C,UL,TPU,UL758,ROHS,REACH,CE,ISO9001-2015,ISO13485,IATF16949
Place of Origin :
Guangdong, China
Brand Name :
linkecable
MOQ :
1000m
Price :
Negotiable
Packaging Details :
According to requirement
Delivery Time :
7-15 days
Payment Terms :
Advance 30% deposit and ship after receiving 70% final payment
Supply Ability :
100000000
Model NO. :
FLRY-B
Conductor Material :
Copper
Sheath Material :
PVC
Insulation Material :
Xlpvc
Material Shape :
Round Wire
Range of Application :
Multimedia, DVD Player, Speaker, Microphone
Brand :
Linke
Voltage :
60V DC/25V AC
Conductor :
Copper
Jacket :
Xlpvc
Insulation :
Xlpvc
Transport Package :
Roll
Specification :
83*83*58CM
Trademark :
LINKE
Origin :
Chian
HS Code :
94054090
Package Size :
85.00cm * 85.00cm * 58.00cm
Package Gross Weight :
30.000kg
Lead Time :
7-15days
Type :
Insulated
Conductor Type :
Twisted wire
Application :
Overhead, Heating, Underground
Customization :
Available
Shipping Cost :
about shipping cost and estimated delivery time.
Return&refunds :
You can apply for a refund up to 30 days after receipt of the products.
Core :
Multiple
conductor material :
copper/Tinned Copper
Exterior material :
customize:PVC、PE、LSFOH、silicone rubber
insulating materials :
customize:PVC、PE 、XLPE、EPR、SIR
specifications :
0.1-450mm²
rated voltage :
300-600V
rated temperature :
-60± 200℃
colour :
customize
package :
By roll
Currency :
US$
Description

XLPE shielded high voltage copper core cable

Product Structure
  • Conductor: Bare copper/Tinned copper

  • Tape: Polyester tape/Aluminum foil

  • Braid: Tinned copper

  • Insulation/sheath: XLPE/XLPO (orange)

High and Low Voltage Cables for Electric Vehicles Shielded High Voltage Cables Unshielded High Voltage   Silicone Ru

Features

  • Rated temperature (℃): -40℃~125℃/150℃

  • Rated voltage (V): AC/DC: 600/900v, 1000/1500V

  • Short-term aging: 240h, in accordance with QC/T 1037

  • Long-term aging: 3000h, in line with QC/T 1037

  • Withstand voltage: 2.1kV/1min. (600/900v), 3.5kV/1min. (1000/1500v)

  • Tear resistance: >20N/mm

  • Minimum bending radius: 5D (OD ≤ 20mm), 6D (OD > 20mm)

  • Environmental requirements: RoHS & REACH

Note: The above product specifications, dimensions and structures may change due to technological

progress. Similar specifications can be designed and manufactured according to customer needs.

XLPE shielded high voltage copper core cable parameters
Product series Cable specifications (mm²) Maximum conductor resistance (m Ω/m at 20 ℃) Rated voltage (AC/DC) Cut off flow Ref (A) Complete outer diameter Ref (mm)

Temperature

resistance

EV shielded cable 2.5 7.60 600V/900V 1000V11500V 30 6.0 -40℃~125℃/150℃
EV shielded cable 4 4.71 600V/900V 1000V1500V 40 6.8 -40℃~125℃/150℃
EV shielded cable 6 3.14 600V/900V 1000V/1500V 52 8.0 -40℃~125℃/150℃
EV shielded cable 10 1.82 600V/900V 1000V/1500V 75 9.5 -40℃~125℃/150℃
EV shielded cable 16 1.16 600V/900V 1000V/1500V 100 11.2 -40℃~125℃/150℃
EV shielded cable 25 0.743 600V/900V 1000V/1500V 125 13.5 -40℃~125℃/150℃
EV shielded cable 35 0.527 600V/900V 1000V1500V 165 14.5 -40℃~125℃/150℃
EV shielded cable 50 0.368 600V/900V 1000V/1500V 215 17.5 -40℃~125℃/150℃
EV shielded cable 70 0.259 600V/900V 1000V/1500V 260 19.5 -40℃~125℃/150℃
EV shielded cable 95 0.196 600V/900V 1000V11500V 320 21.8 -40℃~125℃/150℃
EV shielded cable 120 0.153 600V/900V 1000V/1500V 370 24.5 -40℃~125℃/150℃

LPE unshielded high voltage copper core cable

Product Structure

  • Conductor: Bare copper/Tinned copper

  • Insulation: XLPE or XLPO (orange)

  • Rated temperature: -40℃~125/150℃;

  • Rated voltage: AC/DC: 600/900V, 1000/1500V;

  • Burning test: Flames extinguished at 70S, Keep unburned at least 50mm;

  • Withstand voltage: 1.0kV/30min. Rise to 5.0kV/5min. ( 600/900v) , 1.0kV/30min. Rise to 5.0kV/5min.

  • Continue Rise to 8.0kV ( 1000/1500V );

  • Oil resistance: IRM902, IRM903, Gasoline for 20h in each, Variation of OD≤15%, No cracks;

  • Tear resistance:>20N/mm;

  • Minimum bending radius: 5D (OD ≤ 20mm), 6D (OD > 20mm);

  • Environmental requirements: RoHS & REACH;

Cable use environment:

The warehouse where the cables are stored must not have harmful gases that damage the insulation/

sheath and corrode the metal. During normal use, it is strictly forbidden to contact with acids, alkalis

and mineral oils. Avoid using them in the open air or in exposed environments, and avoid using them

under temperature conditions that do not meet the requirements of the wire and cable standards.

Note: The above product specifications, dimensions and structures may change due to technological

progress. Similar specifications can be designed and manufactured according to customer requirements.

XLPE unshielded high voltage copper core cable parameters

Product series Cable specifications (mm²) Maximum conductor resistance (m Ω/m at 20 ℃) Rated voltage (AC/DC) Cut off flow Ref (A) Complete outer diameter Ref (mm)

Temperature

resistance

EV unshielded cable 2.5 7.60 600V/900V 1000V11500V 30 3.70 -40℃~125℃/150℃
EV unshielded cable 4 4.71 600V/900V 1000V1500V 40 4.50 -40℃~125℃/150℃
EV unshielded cable 6 3.14 600V/900V 1000V/1500V 52 5.00 -40℃~125℃/150℃
EV unshielded cable 10 1.82 600V/900V 1000V/1500V 75 6.50 -40℃~125℃/150℃
EV unshielded cable 16 1.16 600V/900V 1000V/1500V 100 8.30 -40℃~125℃/150℃
EV unshielded cable 25 0.743 600V/900V 1000V/1500V 125 10.20 -40℃~125℃/150℃
EV unshielded cable 35 0.527 600V/900V 1000V1500V 165 11.50 -40℃~125℃/150℃
EV unshielded cable 50 0.368 600V/900V 1000V/1500V 215 13.50 -40℃~125℃/150℃
EV unshielded cable 70 0.259 600V/900V 1000V/1500V 260 15.50 -40℃~125℃/150℃
EV unshielded cable 95 0.196 600V/900V 1000V11500V 320 17.50 -40℃~125℃/150℃
EV unshielded cable 120 0.153 600V/900V 1000V/1500V 370 19.50 -40℃~125℃/150℃

Silicone rubber high voltage unshielded copper cable

  • Conductor: Bare copper/Tinned copper

  • Insulation: Silicone rubber (orange)

  • Rated temperature: -40℃~175/200℃;

  • Rated voltage: AC/DC: 600/900v, 1000/1500V;

  • Burning test: Flames extinguished at 70S, Keep unburned at least 50mm;

  • Withstand voltage: 1.0kV/30min. Rise to 5.0kV/5min. (600/900v) 1.OkV/30min. Rise to 5.0kV/5min.

  • Continue Rise to 8.0kV(1000/1500v)

  • Oil resistance: IRM902, IRM903, Gasoline for 20h ineach, Variation of OD≤15%, No cracks

  • Tear resistance:>15N/mm

  • Minimum bending radius: 5D (OD ≤ 20mm), 6D (OD > 20mm)

  • Environmental requirements: RoHS & REACH

Cable use environment

The warehouse where the cables are stored must not have harmful gases that damage the insulation/

sheath and corrode the metal. During normal use, it is strictly forbidden to contact with acids, alkalis

and mineral oils. Avoid using them in the open air or in exposed environments, and avoid using them

under temperature conditions that do not meet the requirements of the wire and cable standards.

Note: The above product specifications, dimensions and structures may change due to technological

progress. Similar specifications can be designed and manufactured according to customer requirements.

Silicone rubber high voltage unshielded copper cable parameters

Product series Cable specifications (mm²) Maximum conductor resistance (m Ω/m at 20 ℃) Rated voltage (AC/DC) Cut off flow Ref (A) Complete outer diameter Ref (mm)

Temperature

resistance

EV unshielded cable 2.5 7.60 600V/900V 1000V11500V 30 3.70 -40℃~125℃/150℃
EV unshielded cable 4 4.71 600V/900V 1000V1500V 40 4.50 -40℃~125℃/150℃
EV unshielded cable 6 3.14 600V/900V 1000V/1500V 52 5.00 -40℃~125℃/150℃
EV unshielded cable 10 1.82 600V/900V 1000V/1500V 75 6.50 -40℃~125℃/150℃
EV unshielded cable 16 1.16 600V/900V 1000V/1500V 100 8.30 -40℃~125℃/150℃
EV unshielded cable 25 0.743 600V/900V 1000V/1500V 125 10.20 -40℃~125℃/150℃
EV unshielded cable 35 0.527 600V/900V 1000V1500V 165 11.50 -40℃~125℃/150℃
EV unshielded cable 50 0.368 600V/900V 1000V/1500V 215 13.50 -40℃~125℃/150℃
EV unshielded cable 70 0.259 600V/900V 1000V/1500V 260 15.50 -40℃~125℃/150℃
EV unshielded cable 95 0.196 600V/900V 1000V11500V 320 17.50 -40℃~125℃/150℃
EV unshielded cable 120 0.153 600V/900V 1000V/1500V 370 19.50 -40℃~125℃/150℃

Silicone rubber high voltage shielded copper cable parameters

  • Product Structure
  • Conductor: Bare copper/Tinned copper

  • Packing tape: Aluminum foil

  • Braid: Tinned copper

  • Insulation/sheath: Silicone rubber (orange)

  • Rated temperature: -40℃~175/200℃

  • Rated voltage: AC/DC 600/900v, 1000/1500v

  • Burning test: Flames extinguished at 70S, Keep unburned at least 50mm;

  • Withstand voltage:: 1.0kV/30min. Rise to 5.0kV/5min.(600/900v) 1.0kV/30min.Rise to 5.0kV/5min.

  • Continue Rise to 8.0kV (1000/1500V)

  • Oil resistance: IRM902, IRM90, Gasoline for 20h in each, variation of OD≤15%, No cracks

  • Tear resistance:>15N/mm

  • Minimum bending radius: 5D (OD≤20mm), 6D (OD>20mm)

  • Environmental requirements: RoHS & REACH

High and Low Voltage Cables for Electric Vehicles Shielded High Voltage Cables Unshielded High Voltage   Silicone Ru

Silicone rubber high voltage shielded copper cable parameters

Product series Cable specifications (mm²) Maximum conductor resistance (m Ω/m at 20 ℃) Rated voltage (AC/DC) Cut off flow Ref (A) Complete outer diameter Ref (mm)

Temperature

resistance

EV shielded cable 2.5 7.60 600V/900V 1000V11500V 30 6.0 -40℃~125℃/150℃
EV shielded cable 4 4.71 600V/900V 1000V1500V 40 6.8 -40℃~125℃/150℃
EV shielded cable 6 3.14 600V/900V 1000V/1500V 52 8.0 -40℃~125℃/150℃
EV shielded cable 10 1.82 600V/900V 1000V/1500V 75 9.5 -40℃~125℃/150℃
EV shielded cable 16 1.16 600V/900V 1000V/1500V 100 11.2 -40℃~125℃/150℃
EV shielded cable 25 0.743 600V/900V 1000V/1500V 125 13.5 -40℃~125℃/150℃
EV shielded cable 35 0.527 600V/900V 1000V1500V 165 14.5 -40℃~125℃/150℃
EV shielded cable 50 0.368 600V/900V 1000V/1500V 215 17.5 -40℃~125℃/150℃
EV shielded cable 70 0.259 600V/900V 1000V/1500V 260 19.5 -40℃~125℃/150℃
EV shielded cable 95 0.196 600V/900V 1000V11500V 320 21.8 -40℃~125℃/150℃
EV shielded cable 120 0.153 600V/900V 1000V/1500V 370 24.5 -40℃~125℃/150℃
Send your message to this supplier
Send Now

High and Low Voltage Cables for Electric Vehicles Shielded High Voltage Cables Unshielded High Voltage Silicone Ru

Ask Latest Price
Watch Video
Certification :
3C,UL,TPU,UL758,ROHS,REACH,CE,ISO9001-2015,ISO13485,IATF16949
Place of Origin :
Guangdong, China
Brand Name :
linkecable
MOQ :
1000m
Price :
Negotiable
Packaging Details :
According to requirement
Contact Supplier
video
High and Low Voltage Cables for Electric Vehicles Shielded High Voltage Cables Unshielded High Voltage   Silicone Ru
High and Low Voltage Cables for Electric Vehicles Shielded High Voltage Cables Unshielded High Voltage   Silicone Ru
High and Low Voltage Cables for Electric Vehicles Shielded High Voltage Cables Unshielded High Voltage   Silicone Ru
High and Low Voltage Cables for Electric Vehicles Shielded High Voltage Cables Unshielded High Voltage   Silicone Ru
High and Low Voltage Cables for Electric Vehicles Shielded High Voltage Cables Unshielded High Voltage   Silicone Ru
High and Low Voltage Cables for Electric Vehicles Shielded High Voltage Cables Unshielded High Voltage   Silicone Ru
High and Low Voltage Cables for Electric Vehicles Shielded High Voltage Cables Unshielded High Voltage   Silicone Ru

Linke Cable Technology (DongGuan) CO.,LTD

Verified Supplier
1 Years
guangdong, dongguan
Since 2004
Business Type :
Manufacturer
Total Annual :
800000-1000000
Employee Number :
100~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement