24V 80Ah Battery Pack Car Battery Pack for electric scooter
Initial charging
New batteries LFP/LFYP are partly charged from factory. However, before first use it is absolutely necessary to charge the battery to full capacity. This initial charging should be done at maximum current of 1C and the voltage level according to the specification of the cell or battery. Please see specifications of the cell about value of initial charging. Battery capacity in the first cycle gradually grows. In the first few cycles is recommended to avoid rapid discharge to the minimum capacity and we do not recommend quick charging. After about the fifth, sixth cycle, is nothing to prevent the batteries used in full operating cycle according to the manufacturer's specifications for the type of battery.
Standard charging
Because LiFePO4 batteries has no memory effect, charging can be done at any time. Repeated short charge cycles the battery life not significantly changed (within + / - 5%).
Maximum charging currents for single cells or batteries are listed in the manufacturer's specifications for the type of cell.
Specifications | OEM/ODM welcome |
Battery model | LiFePO4 battery |
Nominal voltage | 25.6V |
Nominal capacity | 80Ah |
Cell specification | 3.2V 3300m,Ah 26650 cell |
Cell combination | 8-series 24-parallel |
Type | 24v 80Ah lifepo4 battery pack |
Discharge cut-off voltage | 21.6V |
Charge cut off voltage | 29.2V |
Rated discharge current | 100A 50A 30A 10A available |
Peak discharge current | 150A 100A 50A .. |
Max continuous charge current | 0.5C |
Peak charge current | 1C |
Charge Temperature Range | 0-45C |
Discharge Temperature Range | -20-60C |
Battery size | Customized |
Weight | 25KGS |
Charging cycles | More than 2500 times |
Charger | 10A |
Charge full time | 8 hours |
Rated power | 2400W or customized |
BMS | Yes |
Other products
We focus on 3.2V 6.4V 9.6V 12V 24V 48V 72V 96V 144V LiFePO4 battery pack with capacity from 3300mAh .....100Ah 200Ah 300Ah 400Ah ...welcome
WARNING: Carefully check the minimum voltage as specified cells or batteries. Discharging below this voltage will damage the battery and void the warranty.
Maximum discharging currents for single cells or batteries are listed in the manufacturer's specifications for the type of cell.
Battery and cell checking
Battery check and match any individual cell or battery is done by charging the cells in series, connecting the charger to each individual battery. Checking the battery status and any match is recommended to perform these intervals (ie, discharge / charge cycle):
first charge
after the first cycle
after the 5 cycles
after the 20 cycles
after the 50 cycles
possibly followed by further the anomalies detected about once every 50 to 200 cycles