Heat Meter Er18505 Li SOCl2 Lithium Battery , High Capacity Lithium Batteries
Nominal Capacity | 4000mAh |
Battery discharged at continuous current 2.0mA until voltage reaches cut-off voltage 2.0V at ambient temperature 23±2℃ | |
Nominal Voltage | 3.6 V |
Maximum Continuous Current | 150mA |
Battery with minimum 50% rated capacity discharged at ambient temperature 23±2℃ | |
Maximum Pulse Discharge Current | 300mA |
Battery with minimum 50% rated capacity discharged at max pulse for 3 seconds after 27seconds break. Ambient temperature 23±2℃ | |
Storage Condition | Temperature ≤ 30℃ Humidity ≤ 75%RH |
Operating Temperature | -55℃ to +85℃ |
Battery Dimension | See drawing on pag |
Max Weight | 31.0g |
Self-discharge Rate | 2% |
Max self-discharged rate at ambient temperature 23±2℃ | |
Shelf Life | 10 years |
Ambient temperature 23±2℃ |
1. Battery Characteristic
The rated voltage of the single battery is 3.6V, the operating voltage varies with the load, normally between 3.3V and 3.6V
We offer the specific energy density of 464Wh/kg
The battery can be in work between -55℃ ~ +85℃
Stable operating voltage, more than 90% of the capacity could be output with a fixed voltage
Under the condition of normal temperature, the battery self -discharge rate of no more than 2% per year
Hermetic welding sealing to reduce the leakage for extending the shelf life to more than 10 years
2. Main Applications
Automatic meters (water meter, electric meter, gas meter), conventional meters, etc.
Cardiac pacemaker, respirator, oxygenator, inspection devices, monitoring devices, infusion pump, etc.
RFID products, road toll transponder, IC cards, etc.
3. Manufacturing Advantages
4. Company Advantages
5. FAQS of General Safety Instructions
The Battery should be stored in dry environment.
Keep battery out of the children. If swallowed, please contact a physician at once.
Keep battery out of the children. If swallowed, please contact a physician at once.
They are going to be hot in very short time and it will lead the leakage of gas and toxic materials which may cause a big rupture.
The batteries can’t be short circuit. If positive and negative polarity of a battery is directly connected, this may cause a short circuit and this may lead to toxic materials or gas leakage and/or violent rupture.
The batteries of different electrochemical system, grades, or brands can’t be mixed because it would lead toxic material or gas leakage and/or a big rupture.
Battery disposal method should be in accordance with local and state regulations.