2800mAh UN UL Lithium MnO2 Battery 3000mA Max Pulse Current Hermetic Sealing
Nominal Capacity | 2800mAh |
Battery discharged at continuous current 1mA until voltage reaches cut-off voltage 2.0V at ambient temperature 23±2℃ | |
Nominal Voltage | 3.0 V |
Maximum Continuous Current | 1500mA |
Battery with minimum 50% rated capacity discharged at ambient temperature 23±2℃ | |
Maximum Pulse Discharge Current | 3000mA |
Battery with minimum 50% rated capacity discharged at max pulse for 3 seconds after 27seconds break. Ambient temperature 23±2℃ | |
Storage Condition | Temperature ≤ 30℃ Humidity ≤ 75%RH |
Operating Temperature | -40℃ to +85℃ |
Battery Dimension | See drawing on pag |
Max Weight | 35.0g |
Self-discharge Rate | 2% |
Max self-discharged rate at ambient temperature 23±2℃ | |
Shelf Life | 10 years |
Ambient temperature 23±2℃ |
1. Battery Characteristic
The rated voltage of each battery is 3.0V
The specific energy density of each battery is 240Wh/kg
We provide a wide operating temperature range, from -40℃ to +85℃
Under the condition of normal temperature, the battery self -discharge rate of no more than 2% per year
High capacity, stable performance, stable discharge voltage, and no voltage passivation after long time storage
Battery sealing using the fully sealed structure to reduce the leakage of the battery, make the battery can be stored at room temperature for more than 10 years
The battery safety performance is good, high reliability, and pollution-free, environmental friendly.
2. Main Applications
Automatic meters (water meter, electric meter, gas meter), conventional meters, etc.
Cardiac pacemaker, respirator, oxygenator, inspection devices, monitoring devices, infusion pump, etc.
RFID products, road toll transponder, IC cards, etc.
3. Manufacturing Advantages
4. Company Advantages
5. FAQS of General Safety Instructions
The Battery should be stored in dry environment.
Keep battery out of the children. If swallowed, please contact a physician at once.
Keep battery out of the children. If swallowed, please contact a physician at once.
They are going to be hot in very short time and it will lead the leakage of gas and toxic materials which may cause a big rupture.
The batteries can’t be short circuit. If positive and negative polarity of a battery is directly connected, this may cause a short circuit and this may lead to toxic materials or gas leakage and/or violent rupture.
The batteries of different electrochemical system, grades, or brands can’t be mixed because it would lead toxic material or gas leakage and/or a big rupture.