Nominal Capacity | 1500mAh |
Battery discharged at continuous current 1mA until voltage reaches cut-off voltage 2.0V at ambient temperature 23±2℃ |
Nominal Voltage | 3.0 V |
Maximum Continuous Current | 600mA |
Battery with minimum 50% rated capacity discharged at ambient temperature 23±2℃ |
Maximum Pulse Discharge Current | 1000mA |
Battery with minimum 50% rated capacity discharged at max pulse for 3 seconds after 27seconds break. Ambient temperature 23±2℃ |
Storage Condition | Temperature ≤ 30℃ Humidity ≤ 75%RH |
Operating Temperature | -40℃ to +60℃ |
Battery Dimension | See drawing on pag |
Max Weight | 13.0g |
Self-discharge Rate | 2% |
Max self-discharged rate at ambient temperature 23±2℃ |
Shelf Life | 10 years |
Ambient temperature 23±2℃ |
1. Battery Characteristic
Nominal voltage up to 3.0 V
Energy density up to 450Wh/kg
- Wide Operating Temperature Range
-40°C to +70°C
Self discharge rate is less than 2% per year at room temperature
No passivation effect, instant install-and-use, maintenance free
Ultra thin
Battery of variable dimensions can be selected to fit in the customer’s design
Custom batteries and battery packs are also available
The structure of the battery offers greater safety to meet customer’s requirement for special applications
2. Main Applications
Wireless telecommunication devices
Automatic meters (water meter, electric meter, gas meter), conventional meters, etc.
RFID products, road toll transponder, IC cards, etc.
3. Manufacturing Advantages
- Since 2007,HCB has started to produce Soft Pack Li-MnO2 Battery;
- There are eight patents applied by HCB in Soft Pack Li-MnO2 Battery;
- OEM is workable for HCB and there are varies available models for customers' choice;
- More than 15 million pieces Soft Pack Li-MnO2 Battery are made and sold by HCB until now;
- Most of HCB customers are terminal users, so we experienced in both civil and industrial applications.
4. Warning
- Do not solder the battery directly. In this case the battery can be damaged by the heat. This can cause short circuit and a toxic material or gas leakage and/or violent rupture.
- Do not throw battery into open fire. This can cause violent rupture due to the heat.
- Do not throw the battery into water. This can cause explosion.
- Do not charge primary batteries. This can cause gas leakage and will lead to violent rupture and/or fire.
- Battery compartment should provide sufficient space for battery to expand in case of abuse.
5. Company Advantages
- Quality management system of HCB is conformity with GB/T19001-2008/ISO9001:2008 standard;
- HCB Environment Management System meets the standard GB/T24001-2004/ISO14001:2004;
- The battery can pass drop test if you need;
- Report for safe transport of goods can be provided with you if needed;
- We can provide you with the CE certificate if you need;
- Rosh Standard is workable for HCB Battery;
- UL Standard is workable for HCB Battery.
7. General Safety Instructions
- The battery should be stored in dry environment.
- Do not continue to use the battery if abnormal heat release or leakage occur.
- Please read the manual before using our battery.
- Keep out reach of children. If swallowed, contact a physician at once.
- Do not reverse battery, follow strictly the signs + and – shown on batteries and appliances. If batteries are put in the wrong way they are bound to become hot very quickly. This can lead to gas or toxic material leakage and/or to a violent rupture.
- Do not incinerate of mutilate, may burst or release toxic material.
- Do not deform batteries. Batteries are not to be crushed, drilled into or damaged in any other way. This can lead to toxic material or gas leakage and/or violent rupture.
- Do not throw the battery into water. This can cause explosion.
- Do not charge primary batteries. This can cause gas leakage and will lead to violent rupture and/or fire.