Specifications
Brand Name :
TID POWER
Model Number :
T0308 -T0310, T2508 - T2511
Certification :
ISO9001
Place of Origin :
CN;SHAAN XI
MOQ :
100.0 Piece/Pieces
Price :
negotiable
Payment Terms :
T/T, L/C
Packaging Details :
Suitable packing for export: Cartons+Wooden cases+Pallets+Wrapping Film
Standard :
IEC 61952
Color :
Gray, Customized
Material :
Composite Polymer
Application High Voltage :
High Voltage Raiway
Description

High Voltage Railway Post Insulator

Product

Railway Insulators are important components of railway infrastructure that are used to isolate electrical conductors from their supporting structures. These insulators prevent the flow of electric current between the conductor and the structure, thereby ensuring the safety and reliability of railway operations.

Railway insulators are typically made of materials that are non-conductive and have high electrical resistance, such as porcelain, glass, or polymer materials. Porcelain insulators are the most commonly used type of insulators in railway applications due to their high mechanical strength, excellent electrical insulation properties, and resistance to environmental degradation.

1. Polymer Insulator Character

1.1 High mechanical strength;

1.2 Good performance of hydrophobicity and anti-pollution;

1.3 Excellent electrical Performance;

1.4 Small volume and light weight

2. TID polymer Insulator Character and Advantage:

2.1 We adopt the advanced injection producing technology for housing and the design of the shed adopt unique aerodynamics principle.

2.2 Good Raw material :

We use HTV silicone rubber which hydrophobicity can reach to HC1 level

We use hot dip Galvanizing steel fitting ,the thickness of the zinc more than 86 μm.

We use ECR rod as the core which is high acid resistant. 7200Hr testing passed .

2.3 Special marking design.

We use the double seal design between the rubber and the fitting.

We can mark your logo on the fitting or rubber.

2.4 Excellent Manufacture Technology:

Perfect match between fitting and rod

Perfect bound between silicone rubber and the rod.

High Voltage Railway Post Insulator
Product Description

Parameter of Railway Silicone Rubber Insulator

Products Code Voltage (KV)

SML

(kN)

Bending

Strength

(kN)

Section Length (mm)

Arcing

Distance

(mm)

Creepage

Distance

(mm)

Wet Power

Frequency

Withstand

Voltage(kV)

Lightning impulsed

Withstand

Voltage(kV)

Top Flange (mm) Bottom Flange (mm)
T0308 3 20 9 245±1 170 300 15 95 4-M18 Φ127*Φ162 4-M18 Φ127*Φ162
T0309 12 20 20 156±1 212 450 53 150 4-M12 Φ152*Φ108 4-M12 Φ152*Φ108
T0310 12 50 12.5 253±1 190 420 40 110 4-M12 Φ76*Φ100 4-M12 Φ76*Φ100
T2508 25 50 8 315±2 270 750 75 170 4-M18 Φ140*Φ174 4-M18 Φ140*Φ174
T2508 25 50 8 400±2 330 1000 85 185 4-M18 Φ140*Φ174 4-M18 Φ140*Φ174
T2509 25 60 5 534±5 400 1200 95 250 4-M11 Φ127*Φ162 4-M11 Φ127*Φ162
T2510 25 60 8 495±5 450 1300 125 250 4-M18 Φ127*Φ162 4-M18 Φ127*Φ162
T2511 25 60 5 514±5 400 1200 95 250 4-M11 Φ127*Φ162 4-M11 Φ127*Φ162

Mechanical Parameters

Parameter Description
Flexural strength Maximum flexural force that the insulator can withstand
Tensile strength Maximum tensile force that the insulator can withstand
Hardness Hardness of the insulator

Electrical Parameters

Parameter Description
Insulation resistance Resistance value of the insulator
Dielectric strength Maximum electric field strength that the insulator can withstand under a specified voltage
Dielectric constant Dielectric constant of the insulator, which affects its capacitance value
Leakage distance Distance from the insulator surface to the leakage path

FAQ

1.Is your company a manufacturer or a trader?

* We are the manufacture, 15 years production experience;

* our factory has passed ROSH, SGS, etc;

* Standard: IEC standard;

* Have own quality control.

2.Do you have export experience?

* More than 10 years export experience.

*TID products have been exported to Indonesia, Britain, Russia, Ukraine, Qatar, Romania, UAE, Egypt, USA, Costa rica ,Brazil etc.

3.How to choose products?

*Standard products: Please select standard code according to the above reference file;

*Customized product: please tell us

**Special material requirements; **Fitting model and mark ; ** Voltage;

**Tensile or Bending strength; **Creepage distance or pollution level;

**Structural height or electrical performance.

4.Productive capacity?

*216,000 PCS per year.

Choose US, We shall provide you with all-round technical service!

We warmly welcome you to join us!

We are eager to keep permanent cooperation with you!

Send your message to this supplier
Send Now

High Voltage Railway Post Insulator

Ask Latest Price
Brand Name :
TID POWER
Model Number :
T0308 -T0310, T2508 - T2511
Certification :
ISO9001
Place of Origin :
CN;SHAAN XI
MOQ :
100.0 Piece/Pieces
Price :
negotiable
Contact Supplier
High Voltage Railway Post Insulator
High Voltage Railway Post Insulator
High Voltage Railway Post Insulator

TID POWER SYSTEM CO ., LTD

Verified Supplier
2 Years
Shaanxi, weinan
Since 1998
Business Type :
Manufacturer, Exporter
Employee Number :
50~100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement