The basic function
High precision A/D conversion, readability up to 1/30,000;
It is convenient to call the internal code, and it can be used to observe and analyze tolerances.
Special software technology to enhance the vibration resistance of the system;
Zero tracking range, zero (boot/manual) range, can be set separately;
The speed, amplitude and stable time of digital filtering can be set.
Attached weighing counting function; (single weight with power off protection)
Multiple backlight modes can be selected;
Random charging; With undervoltage indication and protection device;
Random configuration of 6V/4AH maintenance storage battery.
optional
Technical parameters
A/D conversion method: u-turn conversion mode.
A/D conversion rate :20 times/SEC.
Maximum A/D conversion :20bit.
Input signal range: -10mv ~ 15mV.
Input sensitivity: greater than or equal to 1 mu V/e.
Sensor for bridge power supply C5V;