Advantages of DS-3000 equipment
The X-ray source adopts the American VJ X-ray tube, which has a long life and is maintenance-free. The flat-panel detector adopts a 17-inch ultra-clear screen, with fast imaging and no distortion. Four 7-inch material plates or one 13 to 17-inch material plates can be calculated at the same time. Significantly reduce the counting time and avoid excess manpower. Instead, it can assist other personnel to close or change the line and shorten the time of switching and stopping.
Use requirements: After the direct counting of the X-RAY intelligent counting machine is completed, the result data of the counting will be uploaded to the digital control system for updating.
And application occasions:
① WO material return ② single LPN inventory ③ initial inventory/double inventory.
Specifications:
General Specification | |
Working mode | Off-line |
Dimensions(mm) | 800(W)X1380(D)X1950(H) |
Weight | Approx. 800 KG |
Power supply | 110~220VAC 50/60Hz, 1.5KW |
System Computer | |
Industrial PC | Industrial PC with Intel i7 processor (64bit) |
Operating System | Window 10 OS |
Display | 27" FHD LCD Display |
Storage System | |
RAM:16GB, HDD:1TB + SSD:256G | |
Accessories Included | |
Handheld Barcode scanner | / |
Label printer | / |
Inspection Capabilities | |
Tape & reel size | 7" ~ 17" |
Scan height | ≤80mm |
Max inspection speed | 7”~17” |
Tape & Reel | <10s/Reel or 4*7” reel<10s. |
Min component size | 01005 |
Inspection accuracy | ≥99.99% |
X-Ray Tube | |
Type | Closed tube |
Max Voltage | 50KV |
Max. Current | 1000 μA |
Focus spot size | 0.03mm |
Imaging System | |
Type | Flat Panel Detector (FPD) |
Effective detection range: | 430mmx430mm |
Pixel matrix | 3072*3072 pixel |
Pixel size | 139μm |
Frame Rate | 6fpsv |
AD Conversion | 16 bits |
Detectable Package | |
Chip, Bulks, ESD packages, JEDEC Tray, Tube, Transistor. | |
Detectable Components | |
Capacitors, resistors, inductors, beads, crystals, transistors, diodes, FETs, various types of resistors, bile capacitors, detectable connectors, integrated circuit chips, etc | |
Database | |
Support connection with MES, ERP, and WMS Intelligent | |
Safety System | |
Standard | Conformed to FDA-CDRH regulation CFR 21 1020.40 subchapter for cabinet x-ray systems. |
X-ray emission | ﹤ 1μSv/h (FDA-CDRH regulation CFR 21 1020.40 subchapter standard required < 5μSv/h) |
Authority management | Fingerprint and password assessing system. |
Shielded cabinet protection against radiation leakage | |
Real time radiation leakage monitoring meter |