UV-1700SPC
Main features:
●UV-1700 successful implementation of the stringent requirements of high accuracy and reliability measurement to meet the requirements of various applications that can be used in biological research, bio-industry, pharmaceutical analysis, pharmaceutical, teaching and research, environmental protection, food hygiene, clinical examination, health and epidemic prevention and other fields.
●A wide wavelength range, the wavelength range to meet the various requirements of the field.
●Automatic design to achieve the most simple means of measurement.
●LSI design greatly improves the stability and reliability of the system.
●Improved optimization of the optical design, import source and receiver system created a high performance and high reliability.
●Rich measurement methods, with a wavelength scan, time scan, multi-wavelength determination, multi-order derivative determination (optional), dual-wavelength, three-wavelength (optional) DNA protein measurements (optional), and other measurement methods to meet different measurement requirements, and can be displayed directly on a 6-inch screen.
●Based on user requirements optional hole rack, manual four with stand, manual Eighth rack, automatic Eighth frame,
●glass stand, test tube rack, 1cm colorimetric frame, 5cm colorimetric frame, 10cm colorimetric racks.
●Measurement data can be output through the printer with USB interface.
●Can be powered down to save the measurement parameters and data, user-friendly.
●Can achieve more accurate and flexible measurement via PC control, which can meet the needs of different users.
Technical parameters:
Wavelength Range 190~1100nm
Band Width 0.5,1,2,4nm
Wavelength Accuracy ±0.3nm
Wavelength Repeatability ≤0.2nm
Photometric Accuracy ±0.3% τ
Photometric Repeatability 0.15% τ
Stray Light ≤0.05% τ (220nm NaI,360nm NaNO2)
Stability 0.001A/h@500nm
Baseline Flatness ± 0.001A
Photometric Mode T,A,C,E
Wavelength Setting Automatic
Photometric Display Range -4~4A
Display Mode 6 inches high brightness blue LCD
Detector Import Silicon Photodiode
Light Source Import Deuterium Lamp & Tungsten Halogen Lamp
Power Requirement AC 220V/50Hz 110V/60Hz
Power 120W
Dimensions(W*D*H) 480×350×220mm
Weight 28Kg
Exhibition:
Competitive Advantage:
1 LSI design greatly improves the scalability and reliability of the system 2 UV-1700SPC successfully achieved the stringent requirements of high precision and high reliability of the measurement can meet the requirements of various applications, it can be used in biological research, biotechnology industry, pharmaceutical analysis, pharmaceutical, teaching and research, environmental protection and food hygiene, clinical testing, health and epidemic prevention and other fields. 3 Improved optimization of optical design, import source and receiver creating a system of high performance and high reliability 4 UV-1700SPC has strict requirements 0.5 / 1.0 / 2.0 / 4.0nm four spectral bandwidth to meet the pharmacopoeia 5 According to the user's requirements optional hole rack, manual four with rack, manual Eighth rack, automatic Eighth frame, glass frame, test tube rack, 1cm colorimetric frame, 5cm colorimetric frame, 10cm colorimetric racks 6 Rich measurement methods, with a wavelength scan, time scan, multi-wavelength determination, multi-order derivative determination (optional), dual-wavelength, three wavelength (optional) DNA protein measurement (option) and other measuring methods, can meet different measurements requirements, and can be displayed directly on a 6-inch screen 7 A wide wavelength range, which can meet various areas of the wavelength range of requirements 8 Can be powered down to save the measurement parameters and data, user-friendly |
Certification:
The Company:
The Factory: