Macy's headquarter and production base is located in Shanghai, the marketing center in Beijing, and three R & D bases in Jiangsu, Shanghai, and Shandong. To take full advantage of the country's intellectual resources, MACY and the domestic and foreign research unit also conducted deep scientific research cooperation, will continue to put the research achievements into productivity .To better serve our customers, Macy has 12 domestic offices, tailored to meet the needs of your application solutions to improve the value of the products. At the same time continue to serve domestic users, Macy also with distribution in over 20 countries to establish a deep strategic partnership cooperation.
Along with Macy accelerate the pace and rank among the global brand instruments, Macy increasing demands of our own, and we also hope to get the care and support of the community, Let us work and outlook together.Technology, will change because you and us.
AA-1800EL Atomic Absorption Spectrophotometer
Main features
High precision automatic optical system
1800 / mm reticle (dispersion rate) large area grating monochromator, a new type self collimation, all lenses are quartz coating, the detection range and the stability of optical broad to ensure the precision of analysis. Automatic 8 socket configuration 8 independent lamp power supply, can be respectively preheating
Polymer spray chamber
Polymer materials corrosion spray chamber, acid and alkali resistance, includinghydrofluoric acid, either organic or inorganic solution can be the highest sensitivity andstability
Titanium burner
Titanium burner, the optional 50mm and 100mm burner, air cooling pre mixed type,corrosion resistant, resistant to high salt, greatly improve the analysis efficiency andaccuracy of the flame
Automatic analysis
It can automatically accomplish safety ignition, extinction and switching, reliable structure,low fault rate, thus ensuring the sensitivity and reproducibility of the flame method.
The light source system six lamp automatic conversion, can be directly used high performance hollow cathode lamp, improve the sensitivity analysis of the flame, the automatic adjustment of the power supply parameters and the beam position, automaticwavelength scanning and searching peak
Software function
High intelligent software, powerful function, friendly interface English operation.Automatic instruments and additional control, flame, graphite furnace operating mode can be switched automatically, automatic optimization, automatic dilution; mouse operation, automatic setup menu data and correction method
Graphite furnace temperature control
Gas dual temperature control inside and outside, 20 order linear or nonlinear heating, to ensure that the measured elements has the highest sensitivity; furnaceenriched up to 20 times, the longitudinal optically monitoring the graphite tube wall temperature, maximum temperature to 3000 degrees centigrade.
High technology index
AA-1800 atomic absorption spectrophotometer elements testsensitivity meet international best level,sensitivity of less than or equal to0.015μg/mL/1%; baseline drift is less than 0.003Abs/30m, the stability is better than 0.005Abs/4h
Background correction system
Using deuterium hollow cathode lamp advanced and self absorption background deduction of background correction, to eliminate the interference of molecular absorption of low content determination, reducing the noise emission of deuterium lampand prolongs the service life, has excellent stability. Deuterium lamp background signalfor 1A,
background correction ability > 60 times
Intelligent analysis
Greart intelligence, humanized design, flame and graphite furnace atomizer automatic switching, automatic optimization of graphite furnace atomizer, automatically set the flame height adjustment, automatic ignition, automatic optimization of the horizontal position, system automatically sets the gas flow. In the case of power failure, misoperation, acetylene leakage, the system will automatically start the safetyprotection function
Automatic sampler
Integrative design of graphite furnace, using high precision syringe, lowest in 0.5μl samples, with intelligent online dilution and concentration function.
Mainframe
Light Source | ≤8 lamps automatic turret, automatic alignment |
Power Supply | 110/220V (+5% ~ -10%), 60/50Hz; 5000VA |
Lamp Current | pulsed power supply |
Optical System | large 1800 /mm grating ruling, full closed optical system |
Wavelength Range | 185nm-900nm Automatically peak find,a key opticaloptimization function |
Wavelength Accuracy | ±0.15nm |
Wavelength Repeatability | <0.1nm |
Spectral Bandwidth | 0.1,0.2,0.4,0.7,1.0,1.4,2.0nm (7 steps with automatic changeover) |
Baseline Stability | ≤±0.002A/30 min (Static) ≤±0.004A/30min (Dynamic) |
Absorbance Range | 0-4A |
Flame Analytical System
Detector | imported photomultiplier tube |
Burner Head | full titanium combustion head, 50mm or 100mm generalcombustion head |
Atomization Chamber | polymer explosion-proof spray chamber |
Nebulizer | atomizer efficient glass atomizer, can also be customized |
Ignition Type | microcomputer control, automatic ignition |
Gas Control | automatic gas control system |
Detection Limits(Cu) | 0.002μg/mL |
Precision | RSD≤0.5% |
Graphite Furnace Analytical System
Heating Mode | vertical heating |
Temperature Control Method | vertical optical temperature monitoring graphite tube wall temperature |
Temperature Range | room temperature to 3000ºC |
The Program | automatic temperature control up to 20 order |
Temperature Control | the furnace enriched up to 20 times |
Characteristics Volume | 0.4 × 10-12g (Cd) |
Detection Limit | 0.4 × 10-12g (Cd) |
Precision | RSD≤2% |
The Cooling Water | can choose cooling water circulation system |
Safety | the graphite tube damage, water flow air pressure and other alarmtemperature overheating protection |