Specifications
Brand Name :
Macylab
Model Number :
AA-1800EL
Certification :
CE ISO ROHS FCC FAD
Place of Origin :
China
MOQ :
1pcs
Price :
USD16376-USD24558/Set
Payment Terms :
Western Union, MoneyGram, T/T, L/C
Supply Ability :
5000Set / year
Delivery Time :
5-10days
Packaging Details :
Wood Box
Name :
Macylab Flame Atomic Absorption Spectrometer With Graphite Furnace And Flame AA-1800EL
application :
Laboratory Apparatus
Wavelength range :
large 185nm-900nm
Wavelength Accuracy :
±0.15nm
Wavelength Repeatability :
<0.10nm
Spectral Bandwidth :
0.1、0.2、0.4、0.7、1.0、1.4、2.0nm
Absorbance Range :
0-4A
Detector :
imported photomultiplier tube
key words :
Macylab Flame Atomic Absorption Spectrometer With Graphite Furnace And Flame AA-1800EL
Description

AA-1800EL Atomic Absorption Spectrophotometer

AA-1800EL atomic absorption spectrophotometer is absorted the latest international technology and famous universities jointly complete R & D, application experience with decades of spectral instrument. The products include the flame , graphite furnace and hydride generation system, can be equipped with various accessories, flexible configuration program can meet different customer demand. AA-1800 atomic absorption spectrometer can be used for analysis of complex samples ,full automatic multifunctional, various analysis methods can automatically switch, unmanned automatic analysis.

AA-1800EL atomic absorption spectrophotometer is now widely used in scientific research,quality control, disease control, environmental protection, metallurgy, agriculture,chemical industry .Hardware and software design of innovation to ensure the accuracy,safety, ease of use in the analysis of samples, equipment maintenance, simple and convenient.


Technical parameters

Mainframe

Light Source

≤8 lamps automatic turret, automatic alignment

Power Supply

110/220V (+5% ~ -10%), 60/50Hz; 5000VA

Lamp Current

pulsed power supply

Optical System

large 1800 /mm grating ruling, full closed optical system

Wavelength Range

185nm-900nm Automatically peak find,a key opticaloptimization function

Wavelength Accuracy

±0.15nm

Wavelength Repeatability

<0.1nm

Spectral Bandwidth

0.1,0.2,0.4,0.7,1.0,1.4,2.0nm (7 steps with automatic changeover)

Baseline Stability

≤±0.002A/30 min (Static) ≤±0.004A/30min (Dynamic)

Absorbance Range

0-4A


Flame Analytical System

Detector

imported photomultiplier tube

Burner Head

full titanium combustion head, 50mm or 100mm generalcombustion head

Atomization Chamber

polymer explosion-proof spray chamber

Nebulizer

atomizer efficient glass atomizer, can also be customized

Ignition Type

microcomputer control, automatic ignition

Gas Control

automatic gas control system

Detection Limits(Cu)

0.002μg/mL

Precision

RSD≤0.5%


Graphite Furnace Analytical System

Heating Mode

vertical heating

Temperature Control Method

vertical optical temperature monitoring graphite tube wall temperature

Temperature Range

room temperature to 3000ºC

The Program

automatic temperature control up to 20 order

Temperature Control

the furnace enriched up to 20 times

Characteristics Volume

0.4 × 10-12g (Cd)

Detection Limit

0.4 × 10-12g (Cd)

Precision

RSD≤2%

The Cooling Water

can choose cooling water circulation system

Safety

the graphite tube damage, water flow air pressure and other alarmtemperature overheating protection


110v Atomic Absorption Spectrophotometer In Quality Control


Application Field 110v Atomic Absorption Spectrophotometer In Quality Control

Certificate 110v Atomic Absorption Spectrophotometer In Quality Control

Company profile

Macylab Instruments Inc. operates spectroscopic instruments, such as spectrophotometers, UV-visible spectrophotometers, atomic absorption spectrometers, ultra-micro spectrophotometers, atomic fluorescence spectrophotometers, ICP inductively coupled plasma emission spectrometers. Currently, our products have been Widely used in organic chemistry, inorganic chemistry, biochemistry, medicine, environmental protection, metallurgy, petroleum, agriculture and other fields. At the same time, the company has accumulated a wealth of experience in product mechanical structure, optical design, electrical applications and software development, combined with the latest practical needs of the market, will soon launch a number of new analytical instruments.
Macy's headquarter and production base is located in Shanghai, the marketing center in Beijing, and three R & D bases in Jiangsu, Shanghai, and Shandong. To take full advantage of the country's intellectual resources, MACY and the domestic and foreign research unit also conducted deep scientific research cooperation, will continue to put the research achievements into productivity .To better serve our customers, Macy has 12 domestic offices, tailored to meet the needs of your application solutions to improve the value of the products. At the same time continue to serve domestic users, Macy also with distribution in over 20 countries to establish a deep strategic partnership cooperation.
Along with Macy accelerate the pace and rank among the global brand instruments, Macy increasing demands of our own, and we also hope to get the care and support of the community, Let us work and outlook together.Technology, will change because you and us.

110v Atomic Absorption Spectrophotometer In Quality Control

Exhibitions

110v Atomic Absorption Spectrophotometer In Quality Control

110v Atomic Absorption Spectrophotometer In Quality Control

Send your message to this supplier
Send Now

110v Atomic Absorption Spectrophotometer In Quality Control

Ask Latest Price
Brand Name :
Macylab
Model Number :
AA-1800EL
Certification :
CE ISO ROHS FCC FAD
Place of Origin :
China
MOQ :
1pcs
Price :
USD16376-USD24558/Set
Contact Supplier
110v Atomic Absorption Spectrophotometer In Quality Control
110v Atomic Absorption Spectrophotometer In Quality Control

Macylab Instruments Inc.

Active Member
11 Years
beijing, beijing
Since 2010
Business Type :
Manufacturer
Total Annual :
3000000-5000000
Employee Number :
20~50
Certification Level :
Active Member
Contact Supplier
Submit Requirement