Macylab Single Beam Ultraviolet-Visible Spectrophotometer Japanese Imported Light Source
Features
1. Fixed bandwidths.
2. Sealed, solvent-resistant tactile keypad with alpha-numeric entry for file names and units.
3. Pre-aligned deuterium lamp for easy lamp replacement. The status of the lamps may be monitored
4. Powerful built-in program based software UV/Vis Analyst including sophisticated utility programs.
5. Data Download-to-PC software for stand-alone models (Optional)
6. Real-time clock for date and time stamping of results.
7. Data can be saved by USB memory device directly.
Brief Function Introduction
All methods are included as built-in standard; this eliminates the need of software. Online software update via internet.
The local control software includes functions such as: Photometry, Quantitative, Wavelength Scan, Kinetics,DNA/Protein, Multi-wavelength and System Utilities.
Standard Curve
Up to 10 standard solutions may be used to establish calibration equation curve. There is a choice of four methods for fitting a curve through the calibration points: Linear fit, Linear fit through zero, square fit and cubic fit.
Multi-Wavelength
Up to 10 wavelengths may be entered, allowing the measurement of multiple wavelengths on a series of samples.
Wavelength Scan
The Wavelength Scan intervals are 0.1, 0.2, 0.5, 1, 2, 5nm, and High, Medium and Low scan speeds are available. Scan speeds vary from 100 to 2000 nm/min. Wavelengths are scanned from high to low so that the instrument stand by at high wavelength. This minimizes the degradation of UV sensitive samples. Precise control of filter and lamp changes means that their effects are not seen on the final scan. Post-run manipulation includes re-scaling axes, curve tracking and peak picking.
Kinetics
This mode may be used for scanning time course or reacting rate calculations. Abs. vs. time graphs is displayed on the screen in real time.
Wait time and measurement time up to 12 hours may be entered with time intervals of 0.5, 1, 2,5, 10, 30, seconds and 1 min.
Post-run manipulation includes re-scaling, curve tracking and selection of the part of the curve required for the rate calculation. Rate is calculated using a linear regression algorithm before multiplying by the entered factor.
DNA/Protein Test
Concentration and DNA purity are calculated by
Absorbance ratios 260nm/280nm or 260nm/230nm with optional subtracted absorbance at 320nm
DNA Concentration=62.9*A260-36.0*A280
Or 49.1*A260-3.48*A230
Protein Concentration=1552*A260-757.3*A280
Or 183*A260-75.8*A230
Other wavelengths and factors may be entered
Our advantage
Quality | 1. Our products have good quality and very positive reputations in the market. 2. Customers are very happy with them and have a lot of good comments about our intruments and service. |
Delivery Time | 1. We can get them ready 3-5 days after order confirmation for small orders. 2. For big quantities, need to be confirmed. 3. In most cases, fast delivery is guaranteed. |
Technical Support | 1. We have service manual. If not, detailed documents or videos will be provided. 2. We can provide online training in our factory. 3. We can have video conference at any time. |
Aftersales Support | 1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference. 2. Within warranty, we will solve the problem for you with no charge(except for consumables). 3. You can call, text or email us at any time. We have good English speakers. |
Warranty Time | One year and extendable |
Certificate
Exhibition
FAQ
Q1: What about the M.O.Q?
A1: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.
Q2: Sample order is OK?
A2: Sample order is no problem.
Q3: What' s kind of shipment for customer choosing?
A3: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.