Specifications
Brand Name :
Macylab
Model Number :
IPC6800
Certification :
CE,FCC,FDA,ROHS,9001
Place of Origin :
China
MOQ :
1pcs
Price :
negotiable
Payment Terms :
Western Union, MoneyGram, T/T
Supply Ability :
5000set/M
Delivery Time :
at once
Packaging Details :
Waterproof paper then Carton
Shipping/Storage Ambient Temperatur :
15℃-25℃
Atmospheric pressure :
≤70%
Power Supply :
220±10V 50-60MHz
Working Humidity :
≤70%
Working Temperature :
away from the instrument, electric field: E﹤2V/m
name :
Macylab Inductively Coupled Plasma Optical Emission Spectrometer Instrument Icp-6800
Description

Macylab instrument factory ICP-6800 Inductively Coupled Plasma Optical Emission Spectrometer

Application Field )

Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.

At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.

Application Environment

CONTENT RANGE

Shipping/Storage Ambient Temperature 15℃-25℃

Shipping/Storage Relative Humidity ≤70%

Atmospheric pressure 86-106 kPa

Power Supply 220±10V 50-60MHz

Working Humidity ≤70%

Working Temperature 15℃-30℃

RFPower technical parameter:

Circuit type: solid-state RF power supply, with function of automatch

Frequency: 27.12MHz±0.05%

Frequency Stability: <0.1%

Power Output: 800W—1200W

Power Output Stability: <0.3%

Escaped RF radiation: 30cm away from the instrument, electric field: E﹤2V/m

Sampling System Technical Parameter:

Output working coil inner diameter :25mm

Torque tube: Three concentric, external diameter 20mm

Coaxial nebulizer:Outer diameter 6mm

Double barrel atomizing chamber: Outer diameter 34mm

Gas Flow Controls

1. Plasma Argon Flowmeter:(100-1000)L/h (1.6-16L/min)

2. Auxiliary Argon Flowmeter:(10-100)L/h (0.16-1.66L/min)

3. Carrier Argon Flowmeter(10-100)L/h (0.16-1.66L/min)

4.Pressure Maintaining Valve(0-0.4MPa)

5.Cooling Water:Temperature: 20-25℃, Rate of Flow>5L/min, Hydraulic Pressure>0.1MPa

Spectrometer

Optics:Czerny-Turner type

Focal length: 1000 mm

Grating: Ion Beam Etching Holographic Grating, 3600L/mm or 2400L/mm

Reciprocal linear dispersion: 0.26nm/mm

Resolution:≤ 0.007nm (3600 line grating);≤0.015nm (2400line grating)

Wavelength range: 3600 line grating:(190nm~500) nm;2400 line grating: (190nm~800) nm

Minimum pace of stepping motor: ≤0.0006 nm

Exit Slit:12μm;Entrance Slit:10μm

Photoelectric Converter Performance

Photomultiplier tube specification: R293/R928

Negative HV on PMT: 0-1000V;Stability: <0.05%

Overall Performance

Wavelength range of scanning: 195nm~500nm(3600L/mm line grating);195nm~800nm(2400L/mm line grating)

Repeatability: RSD(Relative Standard Deviation)≤1.5%

Stability: RSD(Relative Standard Deviation) ≤2%

Detection Limits (µg/L):

Element WL(nm) Limit Element WL(nm) Limit

La

408.672

<3.0

Cr

267.716 <5.0
Ce 413.765

<5.0

Al

396.152

<5.0
Pr

414.311

<5.0

Zr

343.823

<5.0

Nd

401.225 <5.0

Ag

328.068 <3.0
Sm 360.946

<10.0

Sr

407.771

<1.0

Eu

381.967

<1.0

Au

242.795

<5.0

Gd

342.247

<10.0 Pt 265.945

<5.0

Tb

350.917

<3.0

Pd

340.458

<5.0
Dy 353.170 <3.0

Ir

224.268

<10.0
Ho

345.600

<3.0

Rh

343.489

<10.0

Er

337.271

<3.0

Ru

240.272

<5.0

Tm

313.126

<3.0

Ba

455.403

<1.0

Yb

369.419

<1.0

As

228.812

≤15

Lu

261.541 <3.0

Sb

206.833 ≤15
Y 371.030 <1.0

Bi

223.061 ≤10
Sc 335.373

<1.0

Hg

253.652

≤15

Ta

226.230

<5.0

Pb

220.353 ≤15

Nb

313.340

<5.0

Ga 294.364 ≤10
Mn

257.610

<3.0

Se

203.985 ≤10

Mg

279.553

<1.0

Sn

242.949

≤20

B

249.773

<10.0

Te

214.281

≤10

Zn 213.856 <3.0

Ta

226.230 ≤5.0

Co

228.616

<3.0

Th 283.730

≤10

Si

251.611

<10.0

Tl

276.787 ≤30

Ni

232.003

<5.0 Re 227.525 ≤5

Cd

226.502

<3.0 Ge

209.426

≤15

Fe

239.562

<3.0

Os

225.585 ≤1

Ca

393.366

<1.0

W

207.911 ≤10

Mo

281.615

<5.0 Cu

324.754

<3.0

V 310.230 <5.0

Li

670.784

≤3

Be

313.041 <1.0 Na 588.995 ≤20
Ti

334.941

<3.0

K

766.490

≤60

Macylab Inductively Coupled Plasma Optical Emission Spectrometer Instrument Icp-6800Macylab Inductively Coupled Plasma Optical Emission Spectrometer Instrument Icp-6800
Certificates:
Macylab Inductively Coupled Plasma Optical Emission Spectrometer Instrument Icp-6800
Send your message to this supplier
Send Now

Macylab Inductively Coupled Plasma Optical Emission Spectrometer Instrument Icp-6800

Ask Latest Price
Brand Name :
Macylab
Model Number :
IPC6800
Certification :
CE,FCC,FDA,ROHS,9001
Place of Origin :
China
MOQ :
1pcs
Price :
negotiable
Contact Supplier
Macylab Inductively Coupled Plasma Optical Emission Spectrometer Instrument Icp-6800

Macylab Instruments Inc.

Active Member
11 Years
beijing, beijing
Since 2010
Business Type :
Manufacturer
Total Annual :
3000000-5000000
Employee Number :
20~50
Certification Level :
Active Member
Contact Supplier
Submit Requirement