AM35 Injection blow molding machine
Main Technical Parameters
Item | Unit | Data | No | Item | Unit | Data | ||||||||
1 | Dia of screw | Mm | 40 | 13 | Die-heating power | Kw | automation | |||||||
2 | Max. the retical capacity | Cm3 | 220 | 14 | Pressure of hydraulic system | Mpa | 14 | |||||||
3 | Total power for cylinder-heating | Kw | 6.5 | 15 | Max. working pressure of comp. air | Mpa | 1.2 | |||||||
4 | Clamping force of injection mold | Qty | 3 | 16 | Discharge rate of compressed air | M3/min | >0.8m3/min | |||||||
5 | Clamping force of injection mold | Kn | 350 | 17 | Consumption of cooling water | M3/h | 3 | |||||||
6 | Opening stroke | Mm | 120 | 18 | Dimension of machine(L×W×H) | Mm | 3100*1100*2200 | |||||||
7 | Clamping force of blow mold | Kn | 30 | 19 | Machine weight | T | approximately 3.0 | |||||||
8 | Opening stroke of blow mold | mm | 120 | 20 | Range of formability products | L | 0.003-0.6 | |||||||
9 | Idle time | S | 4 | 21 | Height of formability products | Mm | ≤175mm | |||||||
10 | Max. plate size of die(L*W) | Mm | 300*200 | 22 | Dia of formability products | Mm | ≤100mm | |||||||
11 | Min. die thickness | Mm | 180 | 23 | Conveyer belt Motor power | Kw | 0.1 | |||||||
12 | Motor power | Kw | 15 | 24 | Total power | kw | 25 | |||||||
Cavity number of one mold corresponding to products volume.(for references) | ||||||||||||||
| Product volume(ml) | 8 | 15 | 20 | 40 | 60 | 80 | 100 | ||||||
| Cavity quantity | 8 | 6 | 6 | 5 | 5 | 4 | 3 |
1. bottle mouth and thread are of precise measurement, enabling well close match with safe bottle cap.
2. plastic medicine bottle's safe thread can be molding directly, act in connect with safe bottle cap.
3. the size and weight of the product can calculate and design clearly and meet the requirment of the design without any deviation.
4. the joint sseam on the bottle body is smooth, no scrap rubber