ECPMC For Quick Mold Changing System
Product Parameters
Permanent Magnetic Chuck | Electromagnetic Magnetic Chuck | Electro Permanent Magnetic Chuck | |
Magnetic Source | Ndfeb | Coil and Core | Ndfeb Anico |
Magnetic Force Principle | Internal Magnetic Fields | Constant Current | Conversion by Electronic Control Device |
Usage | Manual | Electric Control Device | Electric Control Device |
Precision | About 0.02-0 05 (the Error Increased Bysizes) | About 0.01-0.02 | About 0 002-0.005 |
Potential Risk | Prone to Security Incidents | Prone to Security Incidents | Absolute Safety |
Magnetic Regulation | Unable to Adjust | Electric Control Device to Adjustsuction | Electric Control Device to Adjust Suction |
Suction | Small | Medium | Large |
Residual Magnetism | More Remanence, Demagnetiz Ation Devicerequired | Less Remanence, Demagnetizationdevice Required | Automatic Demagnetiz Ation Withoutdemagnetization Device |
Thermal Deformation | No | Continuous Power On, Heat Generationand Thermal Deformation | No |
Applicable Workpiece | Thin and Small Workpieces | Thin and Small, Medium Sizedworkpieces | All Kinds of Workpieces |
Application | Mainly Used for Grinding Machine | Mainly Used for Grinding Machine | For Grinding/milling/lathe Manchine and Soon. |
Accessories | No | Electric Control Device | Electric Control Device |
Serive Life | 3-5 Years | 6-10 Years | 20 Years |
Product Specification
Model (T) | Dimensions (MM) | Polar count | Suction (KG) | ||
A | B | Thickness | |||
50 | 540 | 540 | 52 | 8 | 6000 |
80 | 600 | 600 | 52 | 11 | 8250 |
100 | 600 | 600 | 52 | 13 | 9750 |
125 | 660 | 690 | 52 | 15 | 11250 |
150 | 750 | 750 | 52 | 19 | 14250 |
200 | 830 | 830 | 52 | 22 | 16500 |
250 | 950 | 950 | 52 | 33 | 24750 |
300 | 950 | 950 | 52 | 33 | 24750 |
350 | 950 | 1050 | 52 | 44 | 33000 |
420 | 1100 | 1200 | 52 | 52 | 39000 |
500 | 1200 | 1300 | 52 | 64 | 48000 |
650 | 1350 | 1450 | 52 | 102 | 76500 |
800 | 1500 | 1600 | 52 | 118 | 88500 |
1000 | 1700 | 1900 | 52 | 150 | 112500 |
1300 | 1900 | 2200 | 52 | 201 | 150750 |
1500 | 2000 | 2400 | 52 | 260 | 195000 |
2000 | 2300 | 2600 | 52 | 329 | 246750 |
2300 | 2400 | 2850 | 52 | 385 | 288750 |
2700 | 2600 | 3050 | 52 | 454 | 340500 |
3200 | 2600 | 3050 | 52 | 454 | 340500 |
4000 | 2950 | 3300 | 52 | 641 | 480750 |
Note: Above mentioned specification is only for one ECPMC. | |||||
Other specifications can be customized ,please contact us for further information. |
Product Introduction
Spec sheet of electronic controlled permanet magnetic chuck for quick mold changing system
Electric control permanent magnetic chuck for quick mold changing system is mainly to improve the efficiency of traditional injection molding machine, punch_x001f_ing machine, and mold clamping machine. The system adopts the magnetization and demagnetization action of the electronic permanent magnetic chuck to clip and replace the mould, you can change the mould within 3 minutes. It can either be installed in a new machine, sold as a standard configuration to the end customer, or be retrofitted to the machine in use, it’s both practical and convenient.
X61 Introduction
X61 standard electronic controlled permanent magnetic chuck is a new type of magnetic chuck, which useelectric pulse to control its magnetism . No electricity is needed when X61 at work, only except in the first1-2 seconds of magnetization and demagnetization process. Magnetism will not lose even in the case of asudden power cut, and the work piece will not move. X61 has the convenience of "Electronic controlledmagnetic chuck" and the safety precision of "Permanent magnet chuck", which is used for high precisionmilling and grinding.
Model | Dimensions(mm) | Polar Distance(mm) | Polar Number | Net Weight(kg) | |||
Length | Breadth | Height | 70*70 | 50*50 | |||
X61-250*250 | 250 | 250 | 68 | 70*70/50850 | 4 | 9 | 31 |
X61-250*300 | 300 | 250 | 6 | 12 | 40 | ||
X61-300*300 | 300 | 300 | 9 | 16 | 48 | ||
X61-300*400 | 400 | 300 | 12 | 20 | 64 | ||
X61-300*500 | 500 | 300 | 15 | 28 | 80 | ||
X61-300*600 | 600 | 300 | 18 | 32 | 96 | ||
X61-300*800 | 800 | 300 | 24 | 48 | 128 | ||
X61- 300*1000 | 1000 | 300 | 30 | 60 | 160 | ||
X61. -400*400 | 400 | 400 | 16 | 25 | 85 | ||
X61-400*500 | 500 | 400 | 20 | 35 | 105 | ||
X61- 400*600 | 600 | 400 | 24 | 40 | 128 | ||
X61- 400*800 | 800 | 400 | 32 | 60 | 170 | ||
X61- 400*1000 | 1000 | 400 | 40 | 75 | 210 | ||
X61- -500*500 | 500 | 500 | 80 | 25 | 49 | 155 | |
X61- 500*600 | 600 | 500 | 30 | 56 | 188 | ||
X61- 500*800 | 800 | 500 | 40 | 84 | 250 | ||
X61- 500*1000 | 1000 | 500 | 50 | 105 | 310 | ||
X61-600*600 | 600 | 600 | 36 | 72 | 225 | ||
X61-600*800 | 800 | 600 | 48 | 96 | 300 | ||
X61-600*1000 | 1000 | 600 | 60 | 120 | 375 | ||
X61-600*1200 | 1200 | 600 | 72 | 144 | 450 | ||
X61- -600*1500 | 1500 | 600 | 90 | 176 | 560 |
Why Choose Us?
Safety, Magnetism Continue 30years Without Electric. Energy saving, Above 95%.
The Clamping Force Can Be As nigh As More Than 20 Kg/cm2.
High Efficiency, Improve The efficiency of More Than 60%.
Very Easy to Use, Fast, Durable, Maintenance Free.
MAGNETIC CLAMPING VS TRADITIONAL CLAMPING
Suitable for clamping of various workpieces without deformation | Clamping tends to deform the workpiece |
Uniform suction, improve processing accurcy | During the machining process, the workpiece generates vibrations, which reduces the machining accuracy and the surface flatness. |
Accurate positioning, convenient clamping | Difficult clamping and inaccurate positioning reduce work efficiency |
No interference position, workpieces can be f machined on five sides at one time | clamping with processing interference positions, workpieces can not be processed in one operation |