Instructions for use
1. Fill the motor with clean water before use, and tighten the water injection and air release bolt.
2. The test run on land shall not exceed one second.
3. Do not use the electric pump.
4. The motor must be fully submerged, but the depth of submergence should not be more than 70 meters.
5. Lead wire and cable joint shall be operated according to regulations (see the figure for details).
6. Order high head submersible pump (high head submersible pump type Atlas) and (high head submersible pump manual).
Conditions of use
The submersible pump can be used continuously under the following conditions:
1. Three phase AC power supply with rated frequency of 50 Hz and rated voltage of 380 ± 5% v.
2. The water level of the submersible pump is less than 70 meters, but the water level of the static water pump shall not exceed 70 meters, The water depth between the lower end of the motor and the bottom of the well is more than 1 m.
3. The water temperature shall not be higher than 20. c.
4. Water quality requirements:
(1) sand content in water shall not be greater than 0.01% (weight ratio);
(2) The pH value ranged from 6.5 to 8.5
(3) The content of chloride ion is not more than 400 mg / L. 5. It is required that the well should be positive and smooth, and there should be no staggered well pipes.
Matters needing attention:
The cable joint shall be carried out in strict accordance with the attached drawings;
1. Before going down the well, check whether the screws of each part are loose, whether the cable is broken, whether the motor is leaking, and whether the rotation of the motor shaft and water pump shaft is flexible and free of obstruction;
2. Before running into the well, check that the motor resistance should be above 150 m Ω
3. Motor water injection should be carefully prevented from false full;
4. Protection switch and starting equipment shall be equipped according to regulations;
5. When the motor is running for 2500d, a major overhaul should be carried out, and a minor overhaul should be carried out at 1500d;
6. When the electric pump is stopped for storage, the water stored in the motor shall be drained completely;
7. It is strictly forbidden to pretend that you don't understand. Disassembly and repair should be carried out in our factory or fixed repair factory;
8. Frequent "start" and "stop" are prohibited:
9. Ground test motor steering shall be carried out within one second in an instant;
10. When installing the electric pump, be careful to prevent foreign matters from falling into the well;
11. Stop the machine for maintenance in case of the following conditions:
(1) The current and voltage exceed the rated value.
(2) The flow rate decreased significantly.
(3) Water pump intermittent water or sound vibration is large.
(4) The protection switch trips frequently.
(5) The motor resistance is less than 0.5 megohm.