Cheap price electromagnetic milk flowmeter with CE certificate
Product features
1. No moving and blocked flow parts in the pipeline, almost no additional pressure loss in the measurement.
2. Measurements results are independent of physical parameters, such as flow distribution, fluid pressure, temperature, density and viscosity.
3. On-site modification of the measuring range available.
4. LCD display, easy to use and simple to operate.
5. Using SMD devices and SMT technology.
6. Using 16-bit embedded processors with fast speed and high accuracy, enhancing the stability of measurement.
7. Anti-interference, reliability, measurement range up to 150:1.
8. Ultra low EMI switch, wide range of power supply voltage.
9. RS485, RS232, Hart and Modbus digital communication signal output.
10. Self-checking function.
Application
Due to its unique advantages, it is widely used in the fields of petroleum, chemical industry, steel, light industry, sewage processing, environmental protection, water conservancy project and pharmacy to measure the volume flow of the conducted liquid mediums, such as acid, alkali, salt solution and so on.
Product Parameters
(1)working pressure: | pipeline: DN10~DN65: ≤ 2.5MPa |
(2)Chamber Material: | Stainless steel, carbon steel |
(3)Power Supply: | 85~265VAC 45~63HZ |
(4)Repeatability Accuracy: | +/-0.1% |
(5)Pipe Size: | DN10~DN1200 |
(6)Output current: | 4~20mADC |
(7)Accuracy: | piped: 0.5 class, 1.0 class |
(8)Warranty: | 20 months |
(9)Life: | 5-7 years |
(10)Measuring range ratio: | 150:1 |
Precautions
1. Try to avoid ferromagnetic objects and equipment with strong electromagnetic fields, so as to avoid the magnetic field affecting the working magnetic field of the sensor and the flow signal.
2. should be installed in a dry and ventilated place, to avoid sun and rain, the ambient temperature should be -20 ~ +60 ° C, relative humidity is less than 85%.
3. There should be plenty of space around the flowmeter for easy installation and maintenance.
Installation requirements
The measurement principle of the electromagnetic flowmeter is that it does not depend on the flow characteristics. If there is a certain turbulence and vortex inside the pipeline, it will be generated in the non-measurement zone (such as elbow, tangential current limit or half-opening shut-off valve upstream). Measurement is irrelevant. If steady-state eddy currents in the measurement zone affect the stability of the measurement and the accuracy of the measurement, then some measures should be taken to stabilize the flow rate distribution:
A. Increase the length of the straight pipe before and after.
B. Using a flow stabilizer.
C. Reduce a section of the measuring point.