Specifications
Brand Name :
VACORDA
Model Number :
HKLD
Place of Origin :
Sichuan, China (Mainland)
MOQ :
1 Piece/Pieces
Price :
$150.00 - $350.00 / Pieces
Supply Ability :
200 Piece/Pieces per Month
Packaging Details :
wooden box
Certification :
CE/TUV/ISO9001/SGS
Product Name :
Simple Electromagnetic Flow Meter Dn150 Dn400 For Liquid Flow Control
Medium :
Sewage, water, Conductive Liquid
Power supply :
220VAC/24VDC/Battery
Output :
4-20mA /4-20mA + Hart
Material :
Carbon Steel/SS304/SS316L
Measuring range :
50Pa~10MPa
Description

Simple Electromagnetic Flow Meter Dn150 Dn400 For Liquid Flow Control

HKLD type intelligent electromagnetic flowmeter is a fully intelligent electromagnetic flowmeter developed by our company using the most advanced technology at home and abroad. Its electromagnetic converter core adopts high-speed central processing unit. The calculation speed is very fast, the precision is high, and the measurement performance is reliable. The sensor adopts non-uniform magnetic field technology and special magnetic circuit structure, the magnetic field is stable and reliable, and the volume is greatly reduced, the weight is reduced, and the flowmeter is characterized by small flow.

Application

Due to its unique advantages, it is widely used in the fields of petroleum, chemical industry, steel, light industry, sewage processing, environmental protection, water conservancy project and pharmacy to measure the volume flow of the conducted liquid mediums, such as acid, alkali, salt solution and so on.

Simple Electromagnetic Flow Meter Dn150 Dn400 For Liquid Flow Control

Features

1. No moving and blocked flow parts in the pipeline, almost no additional pressure loss in the measurement.

2. Measurements results are independent of physical parameters, such as flow distribution, fluid pressure, temperature, density and viscosity.

3. On-site modification of the measuring range available.

4. LCD display, easy to use and simple to operate.

5. Using SMD devices and SMT technology.

6. Using 16-bit embedded processors with fast speed and high accuracy, enhancing the stability of measurement.

7. Anti-interference, reliability, measurement range up to 150:1.

8. Ultra low EMI switch, wide range of power supply voltage.

9. RS485, RS232, Hart and Modbus digital communication signal output.

10. Self-checking function.

Product Parameters

Product Name

Electromagnetic Flowmeter

Repeatability error

+/-0.1%

Accuracy class

0.5 class, 1.0 class

Measured medium temperature

Common rubber lining: -20~+60 ° c

High temperature rubber lining: -20~+90 ° c

PTFE lining: -30~+100 ° c

High temperature vinyl lining: -30~+180 ° c

Rated working pressure

pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa;

DN200~DN1200: ≤ 1.0MPa

Flow rate range

0.3~15m/s

Measured fluid conductivity

≥5μs/cm liquid

Output

4~20mA / 4~20mA + Hart

Electrode material

316L, titanium (Ti), tantalum (Ta), Hastelloy (H),

Platinum (Pt) or other special electrode materials

Working power supply

85~265VAC / 24VDC / Battery

Straight pipe length

pipe: ≥ 5DN in the upper reaches, downstream of greater than or equal to 2DN

Connections

Flange

Protection grade

standard: IP65; IP68(optional)

Explosion-proof mark

mdllBT4

Deatail Images

Simple Electromagnetic Flow Meter Dn150 Dn400 For Liquid Flow ControlSimple Electromagnetic Flow Meter Dn150 Dn400 For Liquid Flow ControlSimple Electromagnetic Flow Meter Dn150 Dn400 For Liquid Flow ControlSimple Electromagnetic Flow Meter Dn150 Dn400 For Liquid Flow Control

Precautions
1. Try to avoid ferromagnetic objects and equipment with strong electromagnetic fields, so as to avoid the magnetic field affecting the working magnetic field of the sensor and the flow signal.
2. should be installed in a dry and ventilated place, to avoid sun and rain, the ambient temperature should be -20 ~ +60 ° C, relative humidity is less than 85%.
3. There should be plenty of space around the flowmeter for easy installation and maintenance.

Installation requirements
The measurement principle of the electromagnetic flowmeter is that it does not depend on the flow characteristics. If there is a certain turbulence and vortex inside the pipeline, it will be generated in the non-measurement zone (such as elbow, tangential current limit or half-opening shut-off valve upstream). Measurement is irrelevant. If steady-state eddy currents in the measurement zone affect the stability of the measurement and the accuracy of the measurement, then some measures should be taken to stabilize the flow rate distribution:
A. Increase the length of the straight pipe before and after.
B. Using a flow stabilizer.
C. Reduce a section of the measuring point.

Send your message to this supplier
Send Now

Simple Electromagnetic Flow Meter Dn150 Dn400 For Liquid Flow Control

Ask Latest Price
Brand Name :
VACORDA
Model Number :
HKLD
Place of Origin :
Sichuan, China (Mainland)
MOQ :
1 Piece/Pieces
Price :
$150.00 - $350.00 / Pieces
Supply Ability :
200 Piece/Pieces per Month
Contact Supplier
Simple Electromagnetic Flow Meter Dn150 Dn400 For Liquid Flow Control
Simple Electromagnetic Flow Meter Dn150 Dn400 For Liquid Flow Control
Simple Electromagnetic Flow Meter Dn150 Dn400 For Liquid Flow Control

Sichuan Vacorda Instruments Manufacturing Co., Ltd

Active Member
7 Years
sichuan, zigong
Since 1997
Business Type :
Manufacturer, Exporter, Seller
Total Annual :
100W-150W
Employee Number :
>150
Certification Level :
Active Member
Contact Supplier
Submit Requirement