DN10~DN2200 Electromagnetic Water Flow Meter Fully Welded
Electromagnetic Water Flow Meter Applicable to conductive liquid;
Widely used in industries such as petroleum, chemical engineering, iron and steel,food, power, paper making, water treatment,
petrochemical, medicine etc.
A magmeter utilizes a set of coils and a pair of electrodes for flow measurement. The meter’s coils are driven by the transmitter with an applied current. Once powered, a magnetic field is formed between both coils. When the pipe is full and the fluid begins to flow, the force of the magnetic field causes the negatively and positively charged particles of the fluid to separate as they pass through the magnetic field. This separation causes an induced voltage between the electrodes and sensor.
Electromagnetic Water Flow Meter Features
* Water, wastewater & utility applications
* Available in flanged & wafer styles
* Polyurethane, PTFE & Neoprene liner
* Line sizes available from 1/2in (15mm) to 48in (1200mm) Call us for sizes above 24 inches
* Fully welded construction Withstands sustained vibration
* Dual-compartment transmitter housing keeps electronics isolated from moisture and contamination
* Continuous meter verification confirms meter calibration without interrupting the process
* Electrode coating diagnostic indicates when preventive maintenance is needed, avoiding unexpected downtime
* High process noise diagnostic provides accurate readings to reduce process variability
* Printed report verifies meter performance for regulatory agencies
Electromagnetic Water Flow Meter Parameters
Product Name | Electromagnetic Flowmeter |
Repeatability error | +/-0.1% |
Accuracy class | 0.5 class, 1.0 class |
Measured medium temperature | Common rubber lining: -20~+60 ° c |
High temperature rubber lining: -20~+90 ° c | |
PTFE lining: -30~+100 ° c | |
High temperature vinyl lining: -30~+180 ° c | |
Rated working pressure | pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa; DN200~DN1200: ≤ 1.0MPa |
Flow rate range | 0.3~15m/s |
Measured fluid conductivity | ≥5μs/cm liquid |
Output | 4~20mA / 4~20mA + Hart |
Electrode material | 316L, titanium (Ti), tantalum (Ta), Hastelloy (H), Platinum (Pt) or other special electrode materials |
Working power supply | 85~265VAC / 24VDC / Battery |
Straight pipe length | pipe: ≥ 5DN in the upper reaches, downstream of greater than or equal to 2DN |
Connections | Flange |
Protection grade | standard: IP65; IP68(optional) |
Explosion-proof mark | mdllBT4 |
Deatail Images
Increasing energy demand also provides significant room for growth in advanced flowmeters, especially for ultrasonic flowmeters and Coriolis flowmeters. Transportation monitoring is the fastest growing application of Coriolis and ultrasonic flowmeters in oil and gas applications. Oil prices continue to rise, the calculation of transmission precise becomes very important, and the wrong cost is particularly expensive. These flowmeters can provide the highest level of accuracy and reliability required, and become the mainstream choice for the oil and gas industry.