Eliminate Natural bacteria HEPA filter net Medical Grade Air Purifier
Through high efficiency particulate air filter, molecular sieve, short wave ultraviolet Lilights technology, purification area 200m3, dust collection for PM0.3, and germicidal high efficiency of Staphylococcus Albus, Klebsiella pneumoniae, Aspergillus Niger, natural bacteria, H3N2 virus, etc., sick people have weak resistance and are sensitive to air. Use scene hospital departments such as respiratory, intensive care, transplantation, blood, CT, emergency, endoscopy, fever clinic, burn department, newborn room, etc.
|
Eliminating rates | MKJ4000-S2 |
Eliminating rate of Klebsiella pneumoniae (1h, 30m3 Experimental chamber), % | 100% |
Eliminating rate of Aspergillus Niger (1h, 30m3 Experimental chamber), % | 100% |
Eliminating rate of Staphylococcus Albus (1h, 30m3 Experimental chamber), % | 100% |
Extinction rate of natural bacteria (1h, 60m3 Experimental chamber), % | 99.77% |
Eliminating rate of H3N2 virus (20min, 10m3 Experimental chamber), % | 99.99% |
Competitive Advantage:
· Medical grade HEPA filtration combined with UVC lights
· Removes 100% of white staphylococcus, Aspergillus Niger
· Removes 100% of particles PM0.5 at the air outlet
· Large CADR up to 1706.4 m3/h (1003 CFM)
· Applicable room volume 100 m3 / 3531 ft3 at 20 ACH
· Low Noise max 60 dB with low operating Power max 280W
· Strong Ultraviolet radiation intensity with zero leakage
· Human-machine coexistence
· Easy to move and more effective
Specifications:
Technical parameters of MKJ4000-S2 | |
CADR | 1706.4m3/h |
Klebsiella pneumoniae sterilization rate | 100% |
Aspergillus Niger sterilization rate | 100% |
Sterilization rate of Staphylococcus albus | 100% |
Natural bacteria death rate | 99.77% |
H3N2 influenza virus killing rate | 99.99% |
Purification rate of PM0.5 for one pass | 100% (on-site inspection) |
UV leakage intensity (at 30cm around the device) | 0μw/cm2 |
Dimensions (L×W×H) | 700×400×1576mm |
Input power | Max 280W, 3 levels |
Noise | Max 60dB (A), 3 levels |
Product N. W | 89kg |
Product G. W | 103kg |
Voltage and Frequency | 220V/50Hz |
Applications
Main applications | Respiratory unit, ICU, Emergency unit, Transplantation unit, CT room, Fever clinic unit, Blood wards, Burn wards, Neonatal rooms |
Environment Class I | Laminar flow operation room/ward |
Environment Class II | ICU/Hematological/Burn/Bone Marrow Transplant/Obstetric and Gynecologic/Catheter/Neonatal/Organ Transplant room/ward |
Environment Class III | General/Pediatric/Rooming-in/Gynecologic examination/Treatment/Injection/Dressing/Blood Transfusion/Hemodialysis center/Emergency/Laboratory/Infectious Diseases room/ward |
Public places | The bank, Kindergarten, Movie theaters, fitness halls, clubs, massage rooms, bars, cafes etc |
Home care | Care home such as Asthma, Rhinitis, Dust mites, and Pollen allergies populations/ People with weakened immunity such as major postoperative, hemopathy, Chemoradiotherapy patient/ People suffering from respiratory diseases (Asthma, COPD)/ People with allergies (Pollen allergy, allergic rhinitis, allergic dermatitis)/ Gestational woman, children, the aged etc |
Medical Grade Air Purifier Suitable for people who are sick, weak in resistance, and sensitive to air.
Hospitals units such as Respiratory, Critical Care, Transplantation, Blood, CT, Emergency, Endoscopy, Fever Clinic, Burns Department, Neonatal Rooms.
Schools such as Kindergartens, Elementary schools, High schools.
Public places such as The Prisons, The troops, The Banks, Homes
Using alpha-pure system alpha clean control system, High isolation of small particles is achieved through the polar body HEPA filter membrane, gaseous pollutants are effectively removed through molecular sieve technology, and the precise airflow distribution of fluid power is achieved through high-energy photoions. Fast sterilization.
. α-Pure System technology
· Remove 100% of white staphylococcus
· Remove 100% of particles PM0.5 at the air outlet
· Remove 99.99% of H3N2 viruses
· Medical grade HEPA filtration plus UVC lights
· Large CADR up to 1706.4 m3/h (1004 CFM)
· Applicable room volume 100 m3 / 3531 ft3 at 20 ACH
· Low Noise with low operating power
· Strictly produced as per ISO standards
· Easy to maintain
FAQ
Q: Are you a manufacturer or a trading company?
A: The manufacturer.
Q: Where is the production base?
A: Tongxiang City, Zhejiang Province. The marketing center is located in Xuhui District, Shanghai.
Q: What kind of cooperation can we consider?
A: OBM service. We are looking for strategic agents or distributors in each country.
Q: What is your main product?
A: We are committed to three series and five products, namely Ekeair air sterilizer MKJ4000-S1, MKJ4000-S2, MKJ4000-S4, Ekeair air sterilizer MKJ-A1, Ekeair air quality monitor SC01.
Q: What is your sole agency policy?
A: In order to determine the trial order number, the first and second stages of the purchase number, the sales period, the sales training before marketing, etc., exclusive agreements will be considered.
Q: What is your distribution policy?
A: The allocation agreement will be considered to specify the trial order number and other conditions.
Q: What about the application?
A: Ekeair air disinfection is suitable for people who have higher requirements for air quality, such as inpatients, fever clinics, CT rooms, breathing rooms, etc. Ekeair has played an important role in helping to fight the bioaerosol of Covid-19.
OBM services: