Applications
Main applications | Respiratory unit, ICU, Emergency unit, Transplantation unit, CT room, Fever clinic unit, Blood wards, Burn wards, Neonatal rooms |
Environment Class I | Laminar flow operation room/ward |
Environment Class II | ICU/Hematological/Burn/Bone Marrow Transplant/Obstetric and Gynecologic/Catheter/Neonatal/Organ Transplant room/ward |
Environment Class III | General/Pediatric/Rooming-in/Gynecologic examination/Treatment/Injection/Dressing/Blood Transfusion/Hemodialysis center/Emergency/Laboratory/Infectious Diseases room/ward |
Public places | The bank, Kindergarten, Movie theaters, fitness halls, clubs, massage rooms, bars, cafes etc |
Home care | Care home such as Asthma, Rhinitis, Dust mites, and Pollen allergies populations/ People with weakened immunity such as major postoperative, hemopathy, Chemoradiotherapy patient/ People suffering from respiratory diseases (Asthma, COPD)/ People with allergies (Pollen allergy, allergic rhinitis, allergic dermatitis)/ Gestational woman, children, the aged etc |
Competitive Advantage:
· Medical grade HEPA filtration combined with UVC lights
· Removes 100% of white staphylococcus, Aspergillus Niger experimentally
· Removes 100% of particles PM0.5 at the air outlet
· Large CADR up to 1706.4 m3/h (1003 CFM)
· Applicable room volume 100 m3 at 20 ACH
· Low Noise max 60 dB with low operating Power max 280W
· Strong Ultraviolet radiation intensity with zero leakage
· Human-machine coexistence
· Easy to move and more effective
Specifications:
Technical parameters of MKJ4000-S2 | |
CADR | 1706.4m3/h |
Klebsiella pneumoniae sterilization rate | 100% |
Aspergillus Niger sterilization rate | 100% |
Sterilization rate of Staphylococcus albus | 100% |
Natural bacteria death rate | 99.77% |
H3N2 influenza virus killing rate | 99.99% |
Purification rate of PM0.5 for one pass | 100% (on-site inspection) |
Dimensions (L×W×H) | 700×400×1576mm |
Input power | Max 280W, 3 levels |
Noise | Max 60dB (A), 3 levels |
Product N. W | 89kg |
Product G. W | 103kg |
Voltage and Frequency | 220V/50Hz |
Classification of Environment | MKJ4000-S2 |
Environment Class I | ≤40 m3 |
Environment Class II | ≤100 m3 |
Environment Class III | ≤200 m3 |
Eliminating rates | MKJ4000-S2 |
Eliminating rate of Klebsiella pneumoniae (1h, 30m3 Experimental chamber), % |
100% |
Eliminating rate of Aspergillus Niger (1h, 30m3 Experimental chamber), % |
100% |
Eliminating rate of Staphylococcus Albus (1h, 30m3 Experimental chamber), % |
100% |
Extinction rate of natural bacteria (1h, 60m3 Experimental chamber), % |
99.77% |
Eliminating rate of H3N2 virus (20min, 10m3 Experimental chamber), % |
99.99% |
Medical Grade Air Purifier Suitable for people who are sick, weak in resistance, and sensitive to air.
Hospitals units such as Respiratory, Critical Care, Transplantation, Blood, CT, Emergency, Endoscopy, Fever Clinic, Burns Department, Neonatal Rooms.
Schools such as Kindergartens, Elementary schools, High schools.
Public places such as The Prisons, The troops, The Banks, Homes
Using alpha-pure system alpha clean control system, high isolation of extremely fine particles is achieved through the polar body HEPA filter membrane, gaseous pollutants are effectively removed through molecular sieve technology, and the precise airflow distribution of fluid power is achieved through high-energy photoions. Fast sterilization.
OBM services: