Max 60dBHospital ICU, Hematology Department, And Endoscopy Center Use Mobile Disinfection And Sterilization Products
Removes Polio Mobile Air Sterilization
Bacteria and harmful pathogens, such as coronavirus, can be transmitted in three ways: person to person, person to person on the ground and person to person in the air.
Solutions must be developed to help deal with each of these three modes of communication.
An effective air purification scheme can reduce the cross pollution in the air and prevent the air from spreading to people.
Government guidelines based on the coronavirus pandemic have demonstrated the importance of improving indoor air quality, especially in public areas and busy indoor environments such as manufacturing sites, factories and offices.
Medical grade air purifiers implement health protocols to deal with these three modes of transmission, including effective air purification solutions, which will help ensure the safety of everyone in your place and enable you to continue to operate safely when you can.
Specifications:
Technical parameters of MKJ4000-S2 | |
CADR | 1706.4m3/h |
Klebsiella pneumoniae sterilization rate | 100% |
Aspergillus Niger sterilization rate | 100% |
Sterilization rate of Staphylococcus albus | 100% |
Natural bacteria death rate | 99.77% |
H3N2 influenza virus killing rate | 99.99% |
Purification rate of PM0.5 for one pass | 100% (on-site inspection) |
UV leakage intensity (at 30cm around the device) | 0μw/cm2 |
Dimensions (L×W×H) | 700×400×1576mm |
Input power | Max 280W, 3 levels |
Noise | Max 60dB (A), 3 levels |
Product N. W | 89kg |
Product G. W | 103kg |
Voltage and Frequency | 220V/50Hz |
Eliminating rates | MKJ4000-S2 |
Eliminating rate of Klebsiella pneumoniae (1h, 30m3 Experimental chamber), % | 100% |
Eliminating rate of Aspergillus Niger (1h, 30m3 Experimental chamber), % | 100% |
Eliminating rate of Staphylococcus Albus (1h, 30m3 Experimental chamber), % | 100% |
Extinction rate of natural bacteria (1h, 60m3 Experimental chamber), % | 99.77% |
Eliminating rate of H3N2 virus (20min, 10m3 Experimental chamber), % | 99.99% |
Competitive Advantage:
· Medical grade HEPA filtration combined with UVC lights
· Removes 100% of white staphylococcus, Aspergillus Niger
· Removes 100% of particles PM0.5 at the air outlet
· Large CADR up to 1706.4 m3/h (1003 CFM)
· Applicable room volume 100 m3 / 3531 ft3 at 20 ACH
· Low Noise max 60 dB with low operating Power max 280W
· Strong Ultraviolet radiation intensity with zero leakage
· Human-machine coexistence
· Easy to move and more effective
OBM services: