Specifications
Model Number :
ZLK-PO1
Certification :
CE,ISO13485,FDA
Place of Origin :
China
MOQ :
100PCs
Price :
USD 3-4/Pcs
Payment Terms :
L/C, D/A, T/T,
Delivery Time :
5-8 work days
Packaging Details :
100PCs/Carton Carton Weight:5.5KG Carton Size:54*41*29CM
Material :
ABS plastic
Color :
Blue and white/customized
Certificate :
EC,ISO13485,FDA
Power :
2 dry batteries
Display :
OLED display screen
Power Consumption :
Smaller than 30mA
SpO2 Measuring Range :
0%- 100%
Pulse Rate Measuring Range :
30 bpm - 250 bpm
Automatic turn off :
5 seconds
Accuracy :
±2bpm or±2% select larger
Description

Product Name

Medical Blood Oxygen Saturation Pulse Monitoring Home Heartbeat Heart

Rate Detector Oximeter Finger Clip

Function Specification

Display Information Display Mode
The Pulse Oxygen Saturation(SpO2) LED
Pulse Rate(PR) LED
Pulse Intensity (bar -graph) LED
Pulse wave LED
SpO2 Parameter Specification
Measuring range 0%~-100%, (the resolution is 1%).
Accuracy 70%~100%±2%, Below 70% unspecified.
Optical Sensor

Red light (wavelength is 660nm)

Infrared (wavelength is 880nm)

Pulse Parameter Specification
Measuring range 30bpm~250bpm (the resolution is 1 bpm)
Accuracy ±2bpm or±2% select larger
Pulse Intensity
Range Continuous bar-graph display, the higher display indicate the strong pulse
Battery Requirement
1.5V (AAA size) alkaline batteries x 2 or rechargeable battery
Battery Useful Life
Two batteries can work continally for 20 hours
Dimensions and Weight
Dimensions 57(L) x 31(W) x 32(H) mm .
Weight About 50g (with the batteries)

Medical Saturation Finger Pulse Oximeter Heart Rate Detector

Troubleshooting

Trouble Possible Reason Solution

The SpO2 and Pulse Rate can not be displayed normally

1. The finger is not properly positioned.

2. The patient's SpO2 is too low to be detected.

1. Place the finger properly and try again.

2. Try again; Go to a hospital for a diagnosis if you are sure the device works all right.

The SpO2 and Pulse

Rate are not

displayed stably

1. The finger is not placed inside deep enough.

2. The finger is shaking or the patient is moving.

1. Place the finger properly and try again.

2. Let the patient keep calm

The device can not

be turned on

1. The batteries are drained or almost drained.

2. The batteries are not inserted properly.

3. The malfunction of the device.

1. Change batteries.

2. Reinstall batteries.

3. Please contact the local service center.

The display is off

suddenly

1. The device will power off

automatically when it gets no signal within 5 seconds.

2. The batteries are almost drained.

1. Normal.

2. Change batteries.

Warning

1,The uncomfortable or painful feeling may appear if using the device ceaselessly, especially for the microcirculation barrier patients. It is recommended that the sensor should not be applied to the same finger for over 2 hours.

2,For the individual patients, there should be a more prudent inspecting in the placing process. The device can not be clipped on the edema and tender tissue.

3,The light (the infrared is invisible) emitted from the device is harmful to the eyes, so the user and the maintenance man, can not stare at the light.

4,Testee can not use enamel or other makeup.

5,Testee's fingernail can not be too long.

6,Please peruse the relative content about the clinical restrictions and caution.

7,This device is not intended for treatment.

Operating Guide

1) Insert the two batteries properly to the direction, and then replace the cover.

2) Open the clip as shown in Figure 5.

3) Let the patient's finger put into the rubber cushions of the clip (make sure the finger is in the right position), and then clip the finger.

4) Press the switch button once on front panel.

5) Do not shake the finger and keep t he patient at ease during the process. Meanwhile, human body is not recommended in movement status.

6) Get the infonnation directly from screen display.

7) The button has three functions. When the device is power off, pressing the button can open it; When the device is power on, pressing the button shortly can change direction of the screen; When the device is power on, pressing the button long can change brightness of the screen

► Fingern ails and the luminescent tube should be on the same side

Medical Saturation Finger Pulse Oximeter Heart Rate Detector

Medical Saturation Finger Pulse Oximeter Heart Rate Detector

Send your message to this supplier
Send Now

Medical Saturation Finger Pulse Oximeter Heart Rate Detector

Ask Latest Price
Model Number :
ZLK-PO1
Certification :
CE,ISO13485,FDA
Place of Origin :
China
MOQ :
100PCs
Price :
USD 3-4/Pcs
Payment Terms :
L/C, D/A, T/T,
Contact Supplier
Medical Saturation Finger Pulse Oximeter Heart Rate Detector
Medical Saturation Finger Pulse Oximeter Heart Rate Detector
Medical Saturation Finger Pulse Oximeter Heart Rate Detector
Medical Saturation Finger Pulse Oximeter Heart Rate Detector
Medical Saturation Finger Pulse Oximeter Heart Rate Detector

Hunan Zhongliankang Medical Technology Co.,Ltd.

Active Member
5 Years
hunan, xiangtan
Since 2020
Business Type :
Manufacturer
Total Annual :
100M-1000M
Employee Number :
100~300
Certification Level :
Active Member
Contact Supplier
Submit Requirement