HD Display Medical Oxygen Generators The Cardan Wheel Rotates Freely
Features
Warm and subtle Ingenuity:
Do every detail well , only to provide you with a better comfortable experience .
1. One machine for multiple uses:
Oxygen generator and atomizer are integrated , one machine can be used for two purposes ,
and it can be easily atomized at home . It supports two people to inhale oxygen.
2. 5 liters of large flow:
Medical standard stable oxygen production , adjustable 1-5 liters flow rate ,
oxygen concentration is 93 % ± 3 %.
3. Smart timing:
The oxygen inhalation time can be set according to your own needs ,
and it will automatically shut down after the oxygen inhalation .
4. Visual humidification cup:
Keep abreast of the current remaining water volume to avoid dryness and
discomfort in the nasal cavity caused by the absence of water in the humidifying cup.
5. Comes with wheels:
Convenient and easy to move , oxygen inhalation anytime and anywhere ,
with self-locking function and anti-skid.
Specifications
Product number | OZ-5-01PW0 |
Weight | 17.5 kg |
Physical dimension | 300 * 260 * 520 mm |
Average sound pressure level | ≤ 60 dB ( A ) |
Maximum recommended flow | 5 L / min |
Oxygen concentration | ≥ 90 % ( V / V ) |
Outlet pressure | 30kpa - 60kpa |
Nebulizer pressure range | 70kpa - 170kpa |
Maximum nebulizer rate | Should not be less than 0.18ml / min |
Nebulizer cup capacity | 8 ml |
Power Source | Electricity |
After-sale Service | Online technical support |
Material | Metal, Plastic |
Properties | House-Service Detector Tester |
Color | White |
One button oxygen Old people can do it:
No need for raw materials , add pure water or cool it to the humidification cup,
and press the oxygen production button to produce oxygen .
The elderly can easily operate it by themselves.
Built-in warning Oxygen inhalation is more secure:
Built-in protection automatic detection function , when the machine fails,
the light flashes and the buzzer sounds.
1. Low oxygen concentration / beep yellow light:
Situation : When the oxygen concentration is less than or equal to 82 % ( V / V ).
2. Removal method : turn off the machine and
ask professional maintenance personnel to check and repair.
3. Low pressure / beep , yellow light:
Situation : Abnormal system pressure.
Removal method : turn off the machine and
ask professional maintenance personnel to check and repair.
4. Power failure / beep and red light:
Situation : Sudden power failure of the machine.
Releasing method : Check whether the power supply is loose , if it is loose , plug in the power cord ;
if it is not loose ,turn off the machine and ask a professional to inspect it.