Portable Respiratory Machine with CE And ISO Certification ICU Emergency Advanced Functions Versatile Ventilation
Specifications
Parameter | ST-30H | ST-30K |
Ventilation mode | S/T, CPAP, S, T, PC, VAT | S/T, CPAP, S, T,PC, VAT, HFNC |
Oxygen concentration | 21%-100%, (increment by 1%) | |
Screen size | 5.7 inch color screen | |
Waveform display | Pressure/flow | |
IPAP | 4-30cm H2O | 4-40cm H2O |
EPAR | 4-25cm H2O | |
CPAP | 4-20cm H2O | |
Target tidal volume | 20-2500mL | |
Backup BPM | 1-60BPM | |
Backup time | 0.2 -4.0 S | |
Rise time | 1-6 level | |
Ramp time | 0-60min (increment by 1 min) | |
Ramp pressure | CPAP mode: 4-20cm H20 Other mode: 4-25cm H20 | |
Pressure relief | 1-3 level | |
Spontaneous Timin | 0.2-4.0 S | |
Spontaneous Timax | 0.2-4.0 S | |
I-Trigger setting | Auto, 1-3 level | |
E-Trigger setting | Auto, 1-3 level | |
Trigger lock | Off, 0.3-1.5S | |
Flow of HFNC mode | N/A | 10-70L/min |
Max flov | 210L/min | 300L/min |
Max leak compensation | 90L/min | 120L/min |
Method of pressure measure | The pressure testing tube is on mask side | |
Alarms | Apnea | Disconnection | Low minute volumel Low tidal volume | Power off | Over high pressure | Oxygen unavailable | Excessive oxygen pressure supply | Low oxygen pressure supply | Pressure tube off | Turbine dysfunction|Oxygen sensor failure | Air flow sensor failure | Low pressure | Low battery | Battery depleted |
Advantages:
* Higher treatment pressure, more leak compensation.
In case of high inhalation pressure support (40cm H20) orlarge air leakage, it can still ensure an accurate and stablepressure platform.
Inhalation time function: the minimum spontaneousinhalation time (Timin) prevents premature reversing toexhalation to ensure ventilation time; the maximum (Timax)spontaneous inhalation time prevents the difficulty ofexhalation reversing caused by excessive leakage
* AST-Premium automatic synchronizationtechnology,excellent man-machine synchronization.
The VAT can provide tidal volume similar to volume contramode, and also has the safety of pressure control mode.
* Complete parameters setting.
Trigger-lock function: it can reduce false triggers caused by small airway spasmand airway jitter during exhalation, and improveman-machine synchronization.
* 8 hours back-up battery.
* Accurate oxygen concentration control, more efficient to improve Pa02.
The oxvgen concentration isaccurate and constant, the effect of improving bloodoxygen saturation is hetter.
* Inhalation time function.
the minimum spontaneousinhalation time (Timin) prevents premature reversing toexhalation to ensure ventilation time; the maximum (Timaspontaneous inhalation time prevents the difficulty ofexhalation reversing caused by excessive leakage.