Specifications
Brand Name :
New Life
Model Number :
MPD
Certification :
ISO13485, CE
Place of Origin :
China
MOQ :
5000pcs
Price :
USD0.5-USD5
Payment Terms :
T/T, Western Union
Supply Ability :
2000000pcs/month
Delivery Time :
20-30days
Packaging Details :
1pc/pouch, 25pcs/box
Category :
Drug Abuse TESGTING kits
Format :
CARD MPD 4mm
Specimen :
Urine
Testing time :
5 minu
Shelf Life :
24 Months
application :
MPD drug test
cut-off :
1000ng/
Description

Drug Abuse Test Kit MPD Rapid Test 4mm cassette ,high sensitivity cut-off 1000ng/ml

Product Name

MPD ( ritalinic acid) Rapid Diagnostic Test

Specimen: Urine

Intended Use

The MPD Rapid Test Panel (Urine) is a rapid chromatographic immunoassay for the detection of ritalinic acid in human urine at a cut-off concentration of 1000ng/ml. This test will detect other related compounds, please refer to the Analytical Specificity table in this package insert.

This assay provides only a qualitative, preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography /mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.

Parameter Calibrator Cut-off (ng/mL)
MPD ritalinic acid 1000

Test Principle

The MPD Rapid Test Panel (Urine) is an immunoassay based on the principle of competitive binding. Drugs which may be present in the urine specimen compete against the drug conjugate for binding sites on the antibody.

During testing, a urine specimen migrates upward by capillary action. Ritalinic acid, if present in the urine specimen below the cut-off level, will not saturate the binding sites of the antibody in the test strip. The antibody coated particles will then be captured by immobilized Methylphenidate-protein conjugate and a visible colored line will show up in the test line region. The colored line will not form in the test line region if the ritalinic acid level exceeds the cut-off level, because it will saturate all the binding sites of anti-Methylphenidate antibody.

A drug-positive urine specimen will not generate a colored line in the test line region because of drug competition, while a drug-negative urine specimen or a specimen containing a drug concentration less than the cut-off will generate a line in the test line region. To serve as a procedural control, a colored line will always appear in the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.

DIRECTIONS FOR USE

Bring tests, specimens, and/or controls to room temperature (15-30°C) before use.

Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. For best results, the assay should be performed within one hour.

Using the provided disposable pipette, transfer 3 drops of specimen (approximately 120 µL) to the specimen well (S) of the device and start the timer.

Avoid trapping air bubbles in the specimen well (S), and do not add any solution to the result area.

As the test begins to work, color will migrate across the membrane.

Wait for the colored band(s) to appear. The result should be read at 5 minutes. Do not interpret the result after 8 minutes

INTERPRETATION OF RESULTS

NEGATIVE:* A colored line appears in the Control region (C) and colored lines appears in the Test region (T). This negative result means that the concentrations in the urine sample are below the designated cut-off levels for a particular drug tested.

*NOTE: The shade of the colored lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line.

POSITIVE: A colored line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the urine sample is greater than the designated cut-off for a specific drug.

INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer.

QUALITY CONTROL

A procedural control is included in the test. A colored line appearing in the control line region (C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking and correct procedural technique.

performance characteristics

A side-by-side comparison was conducted using the Rapid Test Cassette (Urine) and GC/MS. The following results were tabulated:

Table 1: Specimen Correlation

Method GC/MS Total Results
MPD Rapid Results Positive Negative
Positive 35 1 36
Test Panel
Negative 2 62 64
Total Results 37 63 100
% Agreement 94.6% 98.4% 97.0%

High Sensitivity Urine MPD Rapid Test 4mm Cassette CARD MPD 4mm

ORIENT NEW LIFE MEDICAL CO., LTD.
Contact: Jerry Meng
Email: Jerry @ newlifebiotest .com
Tel. +86 18657312116
SKYPE enetjerry
Send your message to this supplier
Send Now

High Sensitivity Urine MPD Rapid Test 4mm Cassette CARD MPD 4mm

Ask Latest Price
Brand Name :
New Life
Model Number :
MPD
Certification :
ISO13485, CE
Place of Origin :
China
MOQ :
5000pcs
Price :
USD0.5-USD5
Contact Supplier
High Sensitivity Urine MPD Rapid Test 4mm Cassette CARD MPD 4mm
High Sensitivity Urine MPD Rapid Test 4mm Cassette CARD MPD 4mm

Orient New Life Medical Co.,Ltd.

Active Member
8 Years
zhejiang, ningbo
Since 2009
Business Type :
Manufacturer, Exporter
Total Annual :
10,000,000-15,000,000
Employee Number :
200~300
Certification Level :
Active Member
Contact Supplier
Submit Requirement