Specifications
Brand Name :
New Life
Model Number :
96 wells
Certification :
ISO, CE
Place of Origin :
China
MOQ :
10 kit
Payment Terms :
T/T, Western Union
Supply Ability :
100000kit/month
Delivery Time :
20-35days
Packaging Details :
96T/kit
Method :
Elisa
Format :
96T/KIT
Valid :
24 month
Accuracy :
99.88%
Sensitivity :
99.87%
Application :
Rotavirus Antigen
Description

Rubella IgG ELISA test 96wells/kit, high accuracy, Elisa Sandwich method, for quantitative measurement


Rotavirus (ROV) Antigen Detection Kit



[Product name]

Rotavirus Antigen Detection Kit (Colloidal Gold)

[Packing specification]

Sealed package with foil bags, every bag contains the dosage taken once for each person.

[Intended application]

Acute diarrhea disease in young children is a major cause of morbidity worldwide and is a leading cause of mortality in developing countries. Rotavirus is the most common agent responsible for acute gastroenteritis, mainly in young children. Rotavirus is transmitted by oral-fecal route with an incubation period of 1-3 days. In temperate climates, rotavirus infections occur mainly in the winter months. The Rotavirus Test Device is a rapid chromatographic immunoassay for the qualitative detection of rotavirus in human fecal specimens to aid in the diagnosis of rotavirus infection.

[Inspection principles]

Rotavirus antigen Rapid Test is a immunoassay utilizing highly specific reactions between double antibodies sandwich for the detection of rotavirus antigen in human stool samples.

The function parts of the test kit are diluting liquid and test cards which contain immunological reagent on the chromatographic membrane. The stationary reagent line that has been applied onto the membrane in the test area (T) is otherwise invisible, but if the sample passes through membrane contains rotavirus antigen to the specific rotavirus antibody, the line turns distinctly red in the test area. The control line that has been put on the membrane in the control area (C) invisible before the test turns red during the assay process, thus indicates proper performance of the test device. Regardless of the existence of Rotavirus antigen in the sample, the control line will appear.



[Main components]

Specifications Name of component Quantity Main biochemical compositions
Card type Colloidal gold method test paper card of Rotavirus antigen One card The test contains a membrane strip coated with rotavirus antibody conjugates on the test line, a goat polyclonal antibody against gold-protein conjugate at the control line, and a dye pad which contains colloidal gold particles coated with rotavirus antibody .
Instructions One piece Printing paper
Sample extraction liquid One bottle 2ml Normal saline
Strip type Colloidal gold method test paper strip of Rotavirus antigen One strip The test contains a membrane strip coated with rotavirus antibody conjugates on the test line, a goat polyclonal antibody against gold-protein conjugate at the control line, and a dye pad which contains colloidal gold particles coated with Rotavirus antibody .
Instructions One piece Printing Paper
Sample extraction liquid One bottle 2ml Normal saline




[Storage conditions and period of validity]

Avoid light, dry preservation at 2-30℃,no cryopreserving. The period of validity is 24 months since the date of production


[Test method and limitations]

1. The kit is only used for detecting Rotavirus antigen in the samples of human stool.

2. Accuracy of the detection depends on the sampling progress, if the sampling and storage are improper, or the sample is not fresh, or the sample is conducted freeze and thaw, all above can affect the detection results.

3. If the sample is stored in individual medicines, such as OTC with high concentration and prescription medicines, the detection results may be interfered. If the results are suspicious, please test again.

4. The test card can only be used for qualitative detection of Rotavirus antigen in the human stool samples. If you want to detect specific contents of some indicator, please use relevant special instruments.

5. The positive results only show the existence of Rotavirus antigen in the samples, and which can not be treated the only standard to judge that the organism has infected Rotavirus antigen. And the detection results must be diagnosed by the doctor combining with other clinical symptoms as well as the detection indicators from other laboratories.

6. If the detection results negative, but there are clinical symptoms, we suggest using other clinical methods for testing. The negative results can not completely eliminate the possibility of infecting rotavirus antigen.

[Performance indexes of the products]

1) Detection Limit

Minimal detection limit for Rotavirus antibody is 1/1000.

2) Interfering substances

When the sample concentration is below the level of the material shown in the following list, and does not affect the test results.

Name Concentration
Ascorbic acid 20mg/dL
Oxalic acid 1000mg/dL
Hemoglobin 1000mg/dL
Human serum albumin 2000mg/dL
Bilirubin 60mg/dL
Triglycerides 500mg/dL


3) Cross Reaction

When the sample concentration is below the level of the 107 bacteria/ml , and does not affect the test results.

Name Name
Staphylococcus aureus Neisseria gonorrhoeae
Pseudomonas aeruginosa B streptococcus
Streptococcus C Proteus vulgaris
Mucositis Brenham cocci Feces Enterococcus
White rosary Proteus variation
Neisseria meningitidis Acinetobacter
Chlamydia trachomatis Salmonella
Calcium acetate Acinetobacter Vaginalis
E. coli


The results show that those bacterias in stool specimens above are all negative.



[Descriptions and notes]

1. The test strip /test card can only be used for in vitro diagnosis test. And which is suitable for testing the samples of human stool samples, and you may not get accurate results about other body fluid and samples.

2. In the test environment, there shall be not wind, no high temperature and high humidity; the test environment shall be not too dry.

3. When the package is opened, the test stripe/card shall be tested as soon as possible, to avoid being stayed in the air for a long time, resulting in damp and invalid. If the inner package is damaged, the product shall be not used.

4. The kit can be stored at room temperature, avoid damp. The kit stored at low temperature can not be used until it is balanced to room temperature.

5. Operate according to inspection rules of the infectious disease laboratories.

6. If the detection results take on negative, while there are clinical symptoms, we shall conduct further clinical detection. The negative results can not eliminate the possibility of Rotavirus antigen.

7. We can only get initial screening products using this method; any positive results shall be further confirmed adopting other methods.

8. When testing a large number of samples, pleas make tags, avoid confusion.

9. The test card can only be used for disposable in vitro diagnosis; and the same test card can not be used repeatedly. After being frozen or invalid, the test cart must not be used.

ORIENT NEW LIFE MEDICAL CO., LTD.
Contact: Jerry Meng
Email: Jerry @ newlifebiotest .com
Tel. +86 18657312116
SKYPE enetjerry
Send your message to this supplier
Send Now

Disposable Pipette Tips Rotavirus Test Kit 450nm Wavelength Reader 99% Sensitivity

Ask Latest Price
Brand Name :
New Life
Model Number :
96 wells
Certification :
ISO, CE
Place of Origin :
China
MOQ :
10 kit
Payment Terms :
T/T, Western Union
Contact Supplier
Disposable Pipette Tips Rotavirus Test Kit  450nm Wavelength Reader 99% Sensitivity

Orient New Life Medical Co.,Ltd.

Active Member
9 Years
zhejiang, ningbo
Since 2009
Business Type :
Manufacturer, Exporter
Total Annual :
10,000,000-15,000,000
Employee Number :
200~300
Certification Level :
Active Member