Specifications
Brand Name :
New Life
Model Number :
cassette
Certification :
ISO13485, CE
Place of Origin :
China
MOQ :
5000pcs
Price :
USD0.5-USD5
Payment Terms :
T/T, Western Union
Supply Ability :
2000000pcs/month
Delivery Time :
20-30days
Packaging Details :
1pc/pouch, 25pcs/box
Category :
Drug TESGTING kits URINE
Format :
cassette
Specimen :
Urine
Testing time :
5-15 minutes
Shelf Life :
24 Months
application :
ace
cut-off :
400ng
Description

Drug Abuse Test Kit Acetaminophen Rapid Test 4mm cassette ,high sensitivity cut-off 400ng/ml

Product Name

ACE (Acetaminophen) Rapid Diagnostic Test

Specimen: Urine

Intended Use

The ACE Rapid Test Cassette (Urine) is a rapid chromatographic immunoassay for the detection of Acetaminophen in human urine at a cut-off concentration of 5,000ng/mL. This assay provides only a qualitative, preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) or Liquid Chromatography/mass spectrometry (LC/MS) are the preferred confirmatory methods. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used

Parameter Calibrator Cut-off (ng/mL)
ACE Acetaminophen 5000

Test Principle

The ACE Rapid Test Cassette (Urine) is an immunoassay based on the principle of competitive binding. Drugs which may be present in the urine specimen compete against the drug conjugate for binding sites on the antibody. During testing, a urine specimen migrates upward by capillary action. Acetaminophen, if present in the urine specimen below 5,000ng/mL, will not saturate the binding sites of antibody-coated particles in the test. The antibody-coated particles will then be captured by immobilized Acetaminophen conjugate and a visible colored line will show up in the test line region. The colored line will not form in the test line region if the Acetaminophen level exceeds 5,000ng/mL because it will saturate all the binding sites of anti-Acetaminophen antibodies. A drug-positive urine specimen will not generate a colored line in the test line region because of drug competition, while a drug-negative urine specimen or a specimen containing a drug concentration lower than the cut-off will generate a line in the test line region. To serve as a procedural control, a colored line will always appear in the control line region, indicating that proper volume of specimen has been added and membrane wicking has occurred

DIRECTIONS FOR USE

Bring tests, specimens, and/or controls to room temperature (15-30°C) before use.

Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. For best results, the assay should be performed within one hour.

Using the provided disposable pipette, transfer 3 drops of specimen (approximately 120 µL) to the specimen well (S) of the device and start the timer.

Avoid trapping air bubbles in the specimen well (S), and do not add any solution to the result area.

As the test begins to work, color will migrate across the membrane.

Wait for the colored band(s) to appear. The result should be read at 5 minutes. Do not interpret the result after 8 minutes

INTERPRETATION OF RESULTS

NEGATIVE:* A colored line appears in the Control region (C) and colored lines appears in the Test region (T). This negative result means that the concentrations in the urine sample are below the designated cut-off levels for a particular drug tested.

*NOTE: The shade of the colored lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line.

POSITIVE: A colored line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the urine sample is greater than the designated cut-off for a specific drug.

INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer.

QUALITY CONTROL

A procedural control is included in the test. A colored line appearing in the control line region (C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking and correct procedural technique.

Analytical Sensitivity

A drug-free urine pool was spiked with ACE at the following concentrations: 0 ng/mL, 2500 ng/mL, 3750ng/mL, 5000ng/mL, 6250ng/mL, 7500ng/mL and 15000ng/mL.The result demonstrates >99% accuracy at 50% above and 50% below the cut-off concentration. The data are summarized below:

- Concentration Percent of n Visual Result
(ng/mL) Cut-off Negative Positive
0 0% 30 30 0
2500 -50% 30 30 0
3750 -25% 30 25 5
5000 Cut-off 30 15 15
6250 +25% 30 4 26
7500 +50% 30 0 30
15000 3X 30 0 30

Urine ACE Acetaminophen Rapid Test 4mm Cassette , Cut - Off 400ng/Ml

ORIENT NEW LIFE MEDICAL CO., LTD.
Contact: Jerry Meng
Email: Jerry @ newlifebiotest .com
Tel. +86 18657312116
SKYPE enetjerry
Send your message to this supplier
Send Now

Urine ACE Acetaminophen Rapid Test 4mm Cassette , Cut - Off 400ng/Ml

Ask Latest Price
Brand Name :
New Life
Model Number :
cassette
Certification :
ISO13485, CE
Place of Origin :
China
MOQ :
5000pcs
Price :
USD0.5-USD5
Contact Supplier
Urine ACE Acetaminophen Rapid Test 4mm Cassette , Cut - Off 400ng/Ml
Urine ACE Acetaminophen Rapid Test 4mm Cassette , Cut - Off 400ng/Ml

Orient New Life Medical Co.,Ltd.

Active Member
9 Years
zhejiang, ningbo
Since 2009
Business Type :
Manufacturer, Exporter
Total Annual :
10,000,000-15,000,000
Employee Number :
200~300
Certification Level :
Active Member
Contact Supplier
Submit Requirement