Specifications
Brand Name :
New Life
Model Number :
dipcard
Certification :
ISO13485, CE
Place of Origin :
China
MOQ :
5000pcs
Price :
USD0.5-USD5
Payment Terms :
T/T, Western Union
Supply Ability :
2000000pcs/month
Delivery Time :
20-30days
Packaging Details :
1pc/pouch, 25pcs/box
Category :
Drug test kits
Format :
Dipcard
Specimen :
Urine
Testing time :
5-15 minutes
Shelf Life :
24 Months
application :
Synthetic Marijuana
cut-off :
50ng/ml
Description

50ng/ml cut-off Drug Abuse Test Kit K2 Rapid Diagnostic Test dipcard, professional use, detecting Synthetic Marijuana

Product Name

K2 (Synthetic Marijuana) Rapid Diagnostic Test Strip

Specimen: Urine

Product Cat No Specimen Sensitivity Format Kit Size
K2 YD131S3 Urine 50 ng/mL 3mm Strip 100T
YD131C4 4mm Cassette 25T

Intended Use

The Synthetic Marijuana (K2) Rapid Test Cassette (Urine) is a rapid chromatographic immunoassay for the detection of Synthetic Marijuana metabolite in human urine. The synthetic marijuana detected by the test includes, but are not limited to, the metabolites of JWH-018 and JWH-073. This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.

Parameter Calibrator Cut-off (ng/mL)
K2(Synthetic Marijuana) Synthetic Marijuana 50

Test Principle

The K2 Rapid Test Cassette (Urine) is an immunoassay based on the principle of competitive binding. Drugs which may be present in the urine specimen compete against the drug conjugate for binding sites on the antibody. During testing, a urine specimen migrates upward by capillary action. Synthetic Marijuana metabolite, if present in the urine specimen below 50ng/mL, will not saturate the binding sites of antibody-coated particles in the test device. The antibody-coated particles will then be captured by immobilized synthetic marijuana conjugate and a visible colored line will show up in the test line region. The colored line will not form in the test line region if the Synthetic Marijuana metabolite level exceeds 50ng/mL because it will saturate all the binding sites of anti- Synthetic Marijuana antibodies. A drug-positive urine specimen will not generate a colored line in the test line region, while a drug-negative urine specimen or a specimen containing a drug concentration less than the cut-off will generate a line in the test line region. To serve as a procedural control, a colored line will always appear at the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.

DIRECTIONS FOR USE

1. Bring tests, specimens, and/or controls to room temperature (15-30°C) before use.

Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. For best results, the assay should be performed within one hour.

2. Using the provided disposable pipette, transfer 3 drops of specimen (approximately 120 µL) to the specimen well (S) of the device and start the timer.

3. Avoid trapping air bubbles in the specimen well (S), and do not add any solution to the result area.

4. As the test begins to work, color will migrate across the membrane.

5. Wait for the colored band(s) to appear. The result should be read at 5 minutes. Do not interpret the result after 8 minutes

INTERPRETATION OF RESULTS

NEGATIVE:* A colored line appears in the Control region (C) and colored lines appears in the Test region (T). This negative result means that the concentrations in the urine sample are below the designated cut-off levels for a particular drug tested.

*NOTE: The shade of the colored lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line.

POSITIVE: A colored line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the urine sample is greater than the designated cut-off for a specific drug.

INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer.

QUALITY CONTROL

A procedural control is included in the test. A line appearing in the control region

(C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking and correct procedural technique.

Control standards are not supplied with this kit. However, it is recommended that positive and negative controls be tested as good laboratory practice to confirm the test procedure and to verify proper test performance.

ORIENT NEW LIFE MEDICAL CO., LTD.
Contact: Jerry Meng
Email: Jerry @ newlifebiotest .com
Tel. +86 18657312116
SKYPE enetjerry
Send your message to this supplier
Send Now

Rapid Synthetic Marijuana Drug Test Kit K2 50ng/Ml Cut - Off 4mm Cassette

Ask Latest Price
Brand Name :
New Life
Model Number :
dipcard
Certification :
ISO13485, CE
Place of Origin :
China
MOQ :
5000pcs
Price :
USD0.5-USD5
Contact Supplier
Rapid Synthetic Marijuana Drug Test Kit K2 50ng/Ml Cut - Off 4mm Cassette
Rapid Synthetic Marijuana Drug Test Kit K2 50ng/Ml Cut - Off 4mm Cassette

Orient New Life Medical Co.,Ltd.

Active Member
9 Years
zhejiang, ningbo
Since 2009
Business Type :
Manufacturer, Exporter
Total Annual :
10,000,000-15,000,000
Employee Number :
200~300
Certification Level :
Active Member
Contact Supplier
Submit Requirement