urine test High Accuracy LH Ovulation Home fertility test kit , Midstream individual package, private use
INTENDED USE:
LH Ovulation Test is a complete system to help predict the time of ovulation and peak fertility.
It is during this fertile time that pregnancy is most likely to occur. The LH Ovulation Test detects the LH surge in urine, signaling that ovulation is likely to occur in the next 24-48 hours.
Introduction
Ovulation is the release of an egg from the ovary. The egg passes into the fallopian tube where it is ready to be fertilized. In order for pregnancy to occur, the egg must be fertilized by sperm within 24 hours after its release. Immediately prior to ovulation, the body produces a large amount of luteinizing hormone (LH). This is known as an “LH surge” and usually takes place in the middle of the menstrual cycle. LH triggers the release of an egg from the ovary. The Ovulation Predictor Test helps you predict the time of ovulation and peak fertility. It is during this fertile time that pregnancy is most likely to occur. The Ovulation Predictor Test detects the LH surge in urine, signaling that ovulation is likely to occur in the next 24-36 hours. It is important to note that an LH surge and ovulation may not occur in all cycles.
TEST PROCEDURE
1. Bring the pouched test midstream to room temperature (15-30℃) prior to testing. Do not open the pouch until ready to perform the assay.
2. Remove the test midstream from the sealed pouch.
3. Remove the Cap to expose the Absorbent Tip.
4. Hold the midstream by the Thumb Grip with the exposed Absorbent Tip pointing downward. Urinate on the absorbent tip till it is thoroughly wet (at least 5 seconds).
5. Re-cap the test midstream and wait for pink-colored lines to appear. Read result within 3-8 minutes. Do not read result after 10 minutes.
INTERPRETATION OF RESULTS
POSITIVE: If two lines are visible and the Test Line is the same as or darker than the Reference Line, you have detected your LH surge and you will probably ovulate in the next 24-36 hours.
NEGATIVE: If two lines are visible, but the Test Line is lighter than the Reference Line, or if there is no Test Line, you have not detected your LH surge and should continue with daily testing.
INVALID: If no line appears in the Reference Line Area, the result is invalid. Insufficient specimen volume or incorrect test performance are the most likely reasons for an invalid result. Review the procedure and repeat with a new test.
ORIENT NEW LIFE MEDICAL CO., LTD. | |
Contact: | Jerry Meng |
Email: | Jerry @ newlifebiotest .com |
Tel. | +86 18657312116 |
SKYPE | enetjerry |