High Pressure Relief Valve Electric Heating Automatic Desktop Autoclave Sterilizer
Desktop Autoclave Sterilizer Advantage:
◆ Build-in open type water tank
The sterilizer adopts easy-clean open type water tank which can support repeated program running if fully injected
with water.
◆ High-efficiency ultimate vacuum
The sterilizer adopts high-efficiency low noise vacuum system which has excellent effects.
◆ New user interface
LCD screen can display the temperature, pressure, time, running state and fault alarm information, such as sterilization information more intuitive
◆ Safety equipment is complete
Overtemperature multiple control and automatic protection device, the steam generator protection, safety door interlock, double overpressure protection, electronic circuit safety device.
◆ Automatic door structure
Step with quick and convenient operation, and adopt more, moving and pressing technology, make the door seal is more reliable, one-click doors, faster.
◆ Full automatic operation
A bare program, packaging, rubber, custom program, fast, such as sterilization procedures and B&D test, vacuum test program and preheating and drying auxiliary class.
◆ Powerful vacuum drying system
Equipment residual humidity no more than 0.2% after drying, dressings residual moisture after drying, degree of not more than 1%, guaranteed to break the vacuum air aseptic air, sterile items to avoid pollution again.
Model | BTD23-A |
Nominal voltage | AC100/220v , 50HZ /60HZ |
Rated working pressure | 0.11 M Pa/0.21 M Pa |
Chamber volume | 23L |
Net weight | 60KG |
Desktop Autoclave Sterilizer Operating specifications
Preparation before use:
◆ Water tank, add pure water or as required in accordance with the requirements after connecting water, connection equipment power supply.
◆ Sterilizer, turn on the power supply, the power switch in the on state, to be prepared for the program is running;
◆ According to the specified requirements or load type, select the BD program or preheat (for example, if is the class B load with a cavity, generally need to first run BD application, if all are exposed solid equipment can run the preheating process) onto a BD indicate the operator's name or code, date, such as tag, run out into the south in BD experimental procedures, monitoring equipment without leakage, the equipment is normal:
◆ stay sterilization package, strapping not too tight, the built-in chemical indicator CARDS, chemical indicator tape is stuck outside.
Operation after use
◆ open cupboard door, will the power switch in the off state, to cut off the equipment power supply:
◆ Water quality is poor or run after five fire bacteria process must change water:
◆ Evaporator, monthly cleaning (cleaning method in accordance with the manual)
◆ At the end of the daily work, sterilizer should be kept clean inside and outside, you should use a clean cloth and water chamber dirt" clean, according to the instruction weekly maintenance, monthly maintenance.