S6500A Anesthesia System For Adult and Pediatric
Description & Application
The S6500A anesthesia system is widely used in various medical institutions and operating rooms to provide patients with high-quality anesthesia management. It is suitable for a wide variety of surgical and anesthesia procedures including general surgery, cardiac surgery, pediatric surgery, neurosurgery and more. Versatile and highly adjustable, the S6500A Anesthesia System is suitable for patients of different ages, including infants, children and adults. It has advanced anesthesia monitoring and control functions, which can monitor the patient's vital signs and anesthesia depth in real time to ensure the safety and stability of the anesthesia process. The system is easy to operate and has an intuitive user interface for easy operation and monitoring by medical staff.
Features
- 10.4" TFT LCD screen displays the Ventilation parameters, Alarm information and Oscillogram.
- High precision flowmeter, instantly know the fresh gas flow to your patient.
- Integrated breathing circuit design, ensure easy operating and keep tidy.
- Multiple working modes such as volume control and pressure limit, adapt to wide range patient.
- Vaporizer with temperature, pressure, flow compensation and self-lock function, keep safety anytime.
- Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects.
- Pressure-time, Fow-time loop oscillogram and high precision ETCO2, O2 concentration show in real time.
- Vital sign monitor and anesthetic gas monitor are optional.
- ETCO2 module and Anesthesia Gas Scavenging System (AGSS) are optional.
Trust point
- Simplicity: 4 static casters with self-locking function.
- Precision in an anesthesia ventilator with multiple ventilation modes: IPPV, A/C, PCV, SIMV, SIGH and MANUAL.
- Flexible configurations able to customize your requirements.
- International standard and advanced technology suitable for wide range use.
- Compact interface and big screen give you better operating experience.
- Over 5,000 units are installed in more than 200 countries.
- Designed and manufactured by professional team with over 25 years of experience in ICU field.
Safety
- 3 level alarm system, visual and sound alarm information.
- With multiple type of alarm, reminder and protection functions.
- Advanced power management control technology.
- Built-in backup battery provide the emergency power supply to the unit.
- Low O2 pressure alarm and N2O cut-off protection.
Ventilation mode |
IPPV, A/C, PCV,SIMV, SIGH, MANUAL |
Ventilator parameter range |
Flowmeter | O2 (0 ~ 10 L/min) N2O (0 ~ 10 L/min) or AIR (0 ~ 10 L/min) |
Rapid oxygen supply | 25 L/min - 75 L/min |
Tidal volume | 0, 20 mL ~ 1500 mL |
Frequence(Freq) | 1 /min - 100 /min |
I:E | 4:1 - 1:8 |
PEEP | 0 cmH2O - 30 cmH2O |
Pressure triggering sensitivity (PTr) | -20 cmH2O - 0 cmH2O (Based on PEEP) |
Flow trigger sensitivity (FTr) | 0.5 L/min - 30 L/min |
Pressure control (PC) | 5 cmH2O - 70 cmH2O |
SIGH | 0 (off) 1/100 - 5/100 |
Apnea ventilation | OFF, 5s - 60s |
Pressure limit | 20 cmH2O - 100 cmH2O |
Alarm and protection |
The AC power failure alarm | Power failure or no connection |
Internal battery backup low voltage alarm | < 11.3 ± 0.3 V |
No tidal volume | ≤ 5 mL within 6 s |
High oxygen concentration alarm | 19 % - 100 % |
Low oxygen concentration alarm | 18 % - 99 % |
High airway pressure alarm | 2 cmH2O - 100 cmH2O |
Low airway pressure alarm | 0 cmH2O - 98 cmH2O |
High minute volume alarm | Adult (5 L/min ~ 20 L/min) |
Low minute volume alarm | Paed (1 L/min ~ 15 L/min, 0 ~ 10 L/min) |
Continuous pressure alarm | (PEEP+1.5 kPa) over 16 s |
Suffocation warning | 5 s - 60 s no spontaneous ventilation |
The maximum limited pressure | ≤ 12.5 kPa |
Fan error | Show on screen |
Oxygen deficit | Show on screen |
Monitoring parameter |
Frequence(Freq) | 0 /min - 100 /min |
Tidal volume (Vt) | 0 mL - 2000 mL |
MV | 0 L/min - 100 L/min |
Oxygen concentration | 15 % - 100 % |
Ppeak | 0 cmH2O ~ 100 cmH2O |
Cydn | 1 mL/cmH2O ~ 1000 mL/cmH2O |
Working condition |
Gas source | O2, N2O, or AIR |
Pressure | 280 kPa ~ 600 kPa |
Voltage | 100 ~ 240 V |
Power frequency | 50/60 Hz |
Oscillogram |
P-T (pressure - time) |
F-T (flow - time) |
V-T (volume - time) |
ETCO2-T (ETCO2 - time) |
P-V loop (pressure - volume loop) |
F-V loop (flow - volume loop) |
F-P loop (flow - pressure loop) |
Wooden case packing size |
Wooden case packing size :L 740* W 795* H 1540 mm |
G.W. :119 KG N.W. :52.5 KG CBM :0.91 m³ |