High Precision DM6A Veterinary Anesthesia System
The veterinary anesthesia system is widely used in veterinary clinics, hospitals and laboratories and has consistently gained a good reputation from customers all over the world.
DM6A model is specially designed for safe, simple and controllable inhalation anesthesia. The animal veterinary anesthesia system can quickly control the depth of anesthesia with small breathing resistance, from high to low acuity, simple to complex situations, small to large animals, Such as dogs, cats, rabbits, mice, birds, etc.
Advantages
- 10.4" touch screen displays information area, alarm area, monitoring area, and setting area.
- Electronic flowmeter, instantly know the fresh gas flow to animals.
- Vaporizer with temperature, pressure, flow compensation and self-lock function, keep safety anytime.
- Real time pressure-time, flow-time loop oscillogram and high precision ETCO2, O2 concentration detection function included.
- Electronic PEEP makes parameter adjustment more precise.
- Screen displays manual or mechanical ventilation, keeps safety.
- Built-in sensor design with longer use life.
- Wide use range for animals within 200KG.
- ETCO2 module and Anesthesia Gas Scavenging System (AGSS) are optional.
Trust point
- 4 casters with 2 individual brakes.
- Precision in an anesthesia ventilator with multiple ventilation modes: IPPV, A/C, PCV,
- SIMV, SIGH and MANUAL .
- Compact interface and 10.4" TFT LCD touch screen give you better operating experience.
- Flexible configurations able to customize your requirements.
- International standard and advanced technology suitable for wide range use.
- Over 5,000 units are installed in more than 200 countries.
- Designed and manufactured by Superstar Medical with over 14 years of experience in
- veterinary field.
Safety
- Three-level alarm system, visual and sound alarm information.
- Intelligent dual system control ensures safe use in the clinic.
- It has a variety of alarm, reminder and protection functions.
- Advanced power management control technology.
- Built-in backup battery provides up to 2-3 hours of emergency power for the unit.
Specification
Ventilation mode |
IPPV,A/C,PCV,SIMV,SIGH,MANUAL |
Ventilator parameter range |
Flowmeter | O2 (0~5L/min) |
Rapid Oxygen Supply | 25L/min~75L/min |
Tidal Volume (Vt) | 0, 20 mL ~ 1500 mL |
Frequency (Freq) | 1/min~100/min |
I:E Ratio | 2:1~1:6 |
Pressure Triggering Sensitivity | -20 cmH2O~0 cmH2O (Based on PEEP) |
Flow Trigger Sensitivity | 0.5 L/min ~ 30 L/min |
SIGH | 0 (off) 1/100 ~ 5/100 |
Apnea Ventilation | OFF,5 s ~ 60 s |
Pressure Limit | 20 cmH2O ~ 100 cmH2O |
Monitoring parameter |
Frequency (Freq) | 0/min ~ 100/min |
Tidal Volume (Vt) | 0 mL ~ 2000 mL |
Minute Volume (MV) | 0 L/min ~ 100 L/min |
Oxygen concentration | 15 % ~ 100 % |
Alarm and protection |
The AC power failure alarm | Power failure or no connection |
Low voltage alarm for back up battery | <11.3±0.3V |
No tidal volume | ≤5mL within 6s |
High oxygen concentration alarm | 19%-100% |
Low oxygen concentration alarm | 18%-99% |
High airway pressure alarm | 20cmH2O-100cmH2 |
Low airway pressure alarm | 0cmH2O-20cmH2O |
High minute volume alarm | 1L/min-20L/min |
Low minute volume alarm | 0L/min-10L/min |
Continuous pressure alarm | (PEEP+1.5kPa) over 16s |
Suffocation warning | 5s-60s no spontaneous ventilation |
The maximum limited pressure | <12.5 kPa |
Fan error | Show on screen |
Oxygen deficit | Show on screen |
Working condition |
Gas Source | O2, N2O |
Pressure | 280kPa-600kPa |
Voltage | 100-240V |
Power Frequency | 50/60Hz |
Oscillogram |
P-T (pressure – time) |
F-T (flow – time) |
P-V loop (pressure – volume loop) |
V-T (volume – time ) |
ETCO2-T (ETCO2 – time) |
Size |
Wooden case packing size | L 740*W 795*H 1540mm |
G.W. | 119KG |
N.W. | 66KG |
CBM | 0.99m3 |